The effect of hydroxyapatite coating on the fixation of hip prostheses

1994 ◽  
Vol 113 (2) ◽  
pp. 72-77 ◽  
Author(s):  
J. Huracek ◽  
P. Spirig
2015 ◽  
Vol 29 ◽  
pp. 42-56 ◽  
Author(s):  
D Neut ◽  
◽  
RJB Dijkstra ◽  
JI Thompson ◽  
C Kavanagh ◽  
...  

Author(s):  
P. Frayssinet ◽  
J. Hanker ◽  
D. Hardy ◽  
B. Giammara

Prostheses implanted in hard tissues cannot be processed for electron microscopic examination or microanalysis in the same way as those in other tissues. For these reasons, we have developed methods allowing light and electron microscopic studies as well as microanalysis of the interface between bone and a metal biomaterial coated by plasma-sprayed hydroxylapatite(HA) ceramic.An HA-coated titanium hip prosthesis (Corail, Landos, France), which had been implanted for two years, was removed after death (unrelated to the orthopaedic problem). After fixation it was dehydrated in solutions of increasing ethanol concentration prior to embedment in polymethylmethacrylate(PMMA). Transverse femur sections were obtained with a diamond saw and the sections then carefully ground to a thickness of 200 microns. Plastic-embedded sections were stained for calcium with a silver methenamine modification of the von Kossa method for calcium staining and coated by carbon. They have been examined by back-scatter SEM on an ISI-SS60 operated at 25 KV. EDAX has been done on cellular inclusions and extracellular bone matrix.


2003 ◽  
Vol 42 (06) ◽  
pp. 234-239 ◽  
Author(s):  
T. Mumme ◽  
P. Reinartz ◽  
D. Wirtz ◽  
F. U. Niethard ◽  
U. Büll ◽  
...  

Summary Aim: Identification of typical patterns for fluorodeoxyglucose (FDG) uptake in positron emission tomography (PET) to detect aseptic loosening of hip prosthesis (ace-tabular and/or femoral component) and prosthetic infection. Methods: 18 patients with painful hip prosthesis underwent PET using a dedicated full ring scanner after application of 200-300 MBq FDG. The interface between bone and surrounding soft tissue or bone as displayed on coronal slices was divided into 12 segments in accordance with the classifications of Delee and Gruen. FDG uptake in each of the segments was scored (0-3) by two independent observers. Intraoperative findings were regarded as the gold standard. Results: After surgical revision 14 acetabular components and 9 femoral components were found to be loose and prosthetic infection was present in 7 prostheses. Loosening of the acetabular component was correlated to enhanced uptake in the middle of the acetabular interface, while loosening of the femoral component was correlated to enhanced uptake in the proximal and middle segment of the lateral femoral interface and the proximal segment of the medial femoral interface. A similar pattern was found in prosthetic infection with high uptake along the middle portion of the lateral fe-moral interface. In 6 of 7 infected prostheses loosening of the acetabular and of the femoral component was present. Taking the typical uptake patterns as criteria for loosening and grade 3 uptake as an additional criterion for septic loosening the accuracy of PET imaging in the detection of loosening of the acetabular or the femoral component and of prosthetic infection was 72, 78 and 89%, respectively. Conclusion: This pilot study presents FDG-PET as a promising diagnostic tool for patients with painful hip prostheses. Its clinical value should be evaluated in a larger patient population.


2011 ◽  
Vol 197 (3) ◽  
pp. 556-557 ◽  
Author(s):  
Matthew W. Squire

2019 ◽  
Vol 19 (9) ◽  
pp. 5700-5706 ◽  
Author(s):  
Dai-Hua He ◽  
Pu Wang ◽  
Ping Liu ◽  
Xin-Kuan Liu ◽  
Xiao-Hong Chen ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document