Corrosion diagram and quantitative assessment of the resistance to corrosion cracking

1976 ◽  
Vol 11 (2) ◽  
pp. 153-155
Author(s):  
V. V. Gerasimov



2020 ◽  
Author(s):  
José‐Carlos Delgado‐González ◽  
Carlos‐de‐la Rosa Prieto ◽  
Nuria Vallejo‐Calcerrada ◽  
Diana‐Lucía Tarruela‐Hernández ◽  
Sandra Cebada‐Sánchez ◽  
...  


Author(s):  
Wang Zheng-fang ◽  
Z.F. Wang

The main purpose of this study highlights on the evaluation of chloride SCC resistance of the material,duplex stainless steel,OOCr18Ni5Mo3Si2 (18-5Mo) and its welded coarse grained zone(CGZ).18-5Mo is a dual phases (A+F) stainless steel with yield strength:512N/mm2 .The proportion of secondary Phase(A phase) accounts for 30-35% of the total with fine grained and homogeneously distributed A and F phases(Fig.1).After being welded by a specific welding thermal cycle to the material,i.e. Tmax=1350°C and t8/5=20s,microstructure may change from fine grained morphology to coarse grained morphology and from homogeneously distributed of A phase to a concentration of A phase(Fig.2).Meanwhile,the proportion of A phase reduced from 35% to 5-10°o.For this reason it is known as welded coarse grained zone(CGZ).In association with difference of microstructure between base metal and welded CGZ,so chloride SCC resistance also differ from each other.Test procedures:Constant load tensile test(CLTT) were performed for recording Esce-t curve by which corrosion cracking growth can be described, tf,fractured time,can also be recorded by the test which is taken as a electrochemical behavior and mechanical property for SCC resistance evaluation. Test environment:143°C boiling 42%MgCl2 solution is used.Besides, micro analysis were conducted with light microscopy(LM),SEM,TEM,and Auger energy spectrum(AES) so as to reveal the correlation between the data generated by the CLTT results and micro analysis.



VASA ◽  
2017 ◽  
Vol 46 (5) ◽  
pp. 383-388 ◽  
Author(s):  
Henrik Christian Rieß ◽  
Anna Duprée ◽  
Christian-Alexander Behrendt ◽  
Tilo Kölbel ◽  
Eike Sebastian Debus ◽  
...  

Abstract. Background: Perioperative evaluation in peripheral artery disease (PAD) by common vascular diagnostic tools is limited by open wounds, medial calcinosis or an altered collateral supply of the foot. Indocyanine green fluorescent imaging (ICG-FI) has recently been introduced as an alternative tool, but so far a standardized quantitative assessment of tissue perfusion in vascular surgery has not been performed for this purpose. The aim of this feasibility study was to investigate a new software for quantitative assessment of tissue perfusion in patients with PAD using indocyanine green fluorescent imaging (ICG-FI) before and after peripheral bypass grafting. Patients and methods: Indocyanine green fluorescent imaging was performed in seven patients using the SPY Elite system before and after peripheral bypass grafting for PAD (Rutherford III-VI). Visual and quantitative evaluation of tissue perfusion was assessed in an area of low perfusion (ALP) and high perfusion (AHP), each by three independent investigators. Data assessment was performed offline using a specially customized software package (Institute for Laser Technology, University Ulm, GmbH). Slope of fluorescent intensity (SFI) was measured as time-intensity curves. Values were compared to ankle-brachial index (ABI), slope of oscillation (SOO), and time to peak (TTP) obtained from photoplethysmography (PPG). Results: All measurements before and after surgery were successfully performed, showing that ABI, TTP, and SOO increased significantly compared to preoperative values, all being statistically significant (P < 0.05), except for TTP (p = 0.061). Further, SFI increased significantly in both ALP and AHP (P < 0.05) and correlated considerably with ABI, TTP, and SOO (P < 0.05). Conclusions: In addition to ABI and slope of oscillation (SOO), the ICG-FI technique allows visual assessment in combination with quantitative assessment of tissue perfusion in patients with PAD. Ratios related to different perfusion patterns and SFI seem to be useful tools to reduce factors disturbing ICG-FI measurements.





Sign in / Sign up

Export Citation Format

Share Document