Use of laser doppler anemometer for the investigation of turbulent flow of polymer solutions

1975 ◽  
Vol 29 (6) ◽  
pp. 1474-1478 ◽  
Author(s):  
N. A. Pokryvailo ◽  
D. A. Prokopchuk ◽  
Z. P. Shul'man
1992 ◽  
Vol 58 (550) ◽  
pp. 1753-1760
Author(s):  
Hitoshi SUGIYAMA ◽  
Mitsunobu AKIYAMA ◽  
Nao NINOMIYA ◽  
Yoshinori YAKUWA ◽  
Masaru HIRATA

1980 ◽  
Vol 22 (4) ◽  
pp. 207-211 ◽  
Author(s):  
S. M. Fraser ◽  
M. H. Siddig

A DISA two-colour back-scatter laser Doppler anemometer was used to take measurements of mean and fluctuating velocities of an air flow of 4.6 × 104 Reynolds number in a short duct with a normal wall fixed to one side. Walls of 30 and 20 mm height were investigated and the resulting flow patterns were compared.


Author(s):  
Bernhard Gampert ◽  
Thomas Braemer ◽  
Thomas Eich ◽  
Torsten Dietmann

In the present study, the turbulence behaviour of polymer solutions is investigated using laser-Doppler velocimetry (LDV). At the same time, an attempt is made to determine a possibly occurring extension and orientation of the macromolecules by flow-induced birefringence (FIB). Flow-dynamic and rheo-optical experiments are presented which were performed in a smooth square channel in the area of the fully developed turbulent flow. The turbulent flow properties of aqueous solutions of PAAM and Xanthan Gum were studied. The Reynolds number was 30000. The concentration of the polymer solutions was varied between 300 wppm and 800 wppm for PR2300 and between 30 wppm and 120 wppm in the case of Xanthan Gum. The obtained experimental data indicate a significant dependence of the turbulent flow properties on the molecular structure of the polymers used. Furthermore, the extension and orientation of the macromolecules on the turbulent flow properties was investigated.


1985 ◽  
Vol 152 ◽  
pp. 455-478 ◽  
Author(s):  
W. D. McComb ◽  
K. T. J. Chan

A laser-Doppler anemometer (LDA) was used to measure turbulent velocities in drag-reducing fibre suspensions. Measurements of streamwise velocities (and, in one case, the circumferential velocity as well) were made in flow through a straight pipe at x/d = 190, and at Reynolds numbers in the range 1.4 × 104–5.3 × 104. The fibres used were chrysotile asbestos of high aspect ratio (∼ 106), at a concentration of 300 w.p.p.m. They were dispersed in an aqueous solution of a surfactant (0.5% by weight Aerosol OT). In some experiments, the fibre suspensions were supplemented by a drag-reducing polymer (Separan AP30) at a concentration of 150 w.p.p.m. A complete experiment involved passing a quantity of fibre suspension through the apparatus a number of times (at a given Reynolds number) and measuring the velocity distribution across the pipe during each pass. As the amount of drag reduction generally declined with the number of passes (i.e. due to fibre degradation), this provided a convenient way of varying the percentage drag reduction as an experimental parameter. Results were obtained for mean velocity and intensity profiles, autocorrelations, and one-dimensional energy spectra. The mean period of turbulent bursts was determined by measuring autocorrelations with short sampling times.At the lowest Reynolds number (Re = 1.4 × 104), drag reductions of about 70% were obtained during the first two passes. This was accompanied by a reduction in the streamwise intensity below the level obtained in the surfactant solution alone. (Note: The opposite behaviour is found in drag-reducing polymer solutions, where intensity levels are larger than those in the solvent alone.) A measurement of the r.m.s. circumferential velocity showed an increased level (relative to surfactant alone) during this part of the experiment. During further passes, there was a transition to ‘polymer-like’ behaviour, with increased streamwise intensity, which subsequently declined with pass number (and hence drag reduction) towards the result for surfactant alone. This effect had previously been found in preliminary experiments at Re = 9 × 103 (McComb & Chan 1979). Repetition of the experiment a Re = 1.4 × 104, with the addition of Separan AP30, confirmed the existence of this transition from ‘fibre-like’ to ‘polymer-like’ drag reduction. In this case, the drag reduction was smaller (at about 60%), but the mixed suspension was much more resistant to degradation, with transition occurring at the ninth pass. However, such behaviour was not found at higher Reynolds numbers (Re = 3.2 × 104 and 5.3 × 104), in fibre suspensions where increased streamwise intensities occurred, even at high levels of drag reduction (about 70%).Anomalous streamwise autocorrelations were found during ‘fibre-like’ drag reduction but in the ‘polymer-like’ regime they were very similar to those measured in polymer solution, and showed characteristically increased lengthscales. On the other hand, energy spectra were found to be anomalous in all cases and showed an energy deficit at lengthscales of the same order as the fibre length. Finally, mean bursting periods were found to be much increased, with the increases being about the same as those in polymer solutions at the same Reynolds number and percentage drag reduction.


1981 ◽  
Vol 103 (2) ◽  
pp. 116-120 ◽  
Author(s):  
F. J. Walburn ◽  
P. D. Stein

The purpose of this study is to explore the effect of tapering upon the tendency of flow to become turbulent in straight symmetric tubes. Velocity was measured with a laser Doppler anemometer in plexiglass tubes which tapered 0.5 deg, 1.5 deg, and 2.5 deg measured from the centerline to the wall. These angles were comparable to the angles of tapering observed in the abdominal aorta of normal subjects, 1.5 deg ± 0.2 deg (mean ± SEM) (range 0 deg to 3 deg). The transition Reynolds number (based on the diameter of the tube at the piont of measurement) increased as the angle of tapering increased. When the angle of tapering was constant, the transition Reynolds number increased with increasing distance into the tapered section. These observations suggest that tapering of the abdominal aorta tends to promote laminar flow.