Cross-sectional echocardiographic measurement of right atrial and right ventricular size in children with atrial septal defect before and after surgery

1988 ◽  
Vol 9 (4) ◽  
pp. 231-236 ◽  
Author(s):  
Katarina Hanséus ◽  
Gudrun Björkhem ◽  
Nils-Rune Lundström ◽  
Santosa Soeroso
2009 ◽  
Vol 11 (Suppl 1) ◽  
pp. P99
Author(s):  
Wilfred B de Koning ◽  
Saskia E Luijnenburg ◽  
Lennie M van Osch-Gevers ◽  
Derk ten Harkel ◽  
Daniëlle Robbers-Visser ◽  
...  

1978 ◽  
Vol 41 (2) ◽  
pp. 295-301 ◽  
Author(s):  
Alan S. Pearlman ◽  
Jeffrey S. Borer ◽  
Chester E. Clark ◽  
Walter L. Henry ◽  
David R. Redwood ◽  
...  

1982 ◽  
Vol 10 (8) ◽  
pp. 385-390 ◽  
Author(s):  
Gregory P. Fontana ◽  
Jason H. Kirkman ◽  
Thomas G. Disessa ◽  
Arthur D. Hagan ◽  
Satoshi Hiriashi ◽  
...  

2019 ◽  
Vol 40 (Supplement_1) ◽  
Author(s):  
M Komar ◽  
T Przewlocki ◽  
B Sobien ◽  
P Prochownik ◽  
U Gancarczyk ◽  
...  

Abstract Objective Closure of atrial septal defect in patients with borderline shunt is controversial. The aim of the study was to evaluate the outcomes of transcatheter closure of secundum atrial septal defect (ASD) in the patients with the borderline shunt. Methods 215 pts (126 F,89 M) with a mean age of 31.9±18.2 (16–58) years with a small ASD who underwent transcatheter closure were analyzed. All patients had an isolated secundum ASD with pulmonary to systemic blood flow Qp:Qs ratio≤1.5, mean 1.2±0.6 (1.1–1.5). A symptom-limited treadmill exercise test with respiratory gas exchange analysis, transthoracic color Doppler echocardiographic study and Quality of life (QoL) (using the SF36 questionnaire (SF36q)) were repeated in all pts before and 36 months after the procedure. Results The device was successfully implanted in all pts (procedure time 19.1±5.2 (8–38) minutes, fluoroscopy time 8.1±4.4 (6–13) minutes). There were no major complications. The defect echo diameter was 7.7±3.9 (5 - 15) mm. The diameter of the implanted devices ranged from 6 to 18 mm. After 36 months of ASD closure, all the pts showed a significant improvement of exercise capacity. 7 QoL parameters (except mental health) improved at 36 months of follow-up compared with baseline. The mean SF36q scale increased in 168 (78.1%) pts of mean 40.2±20.1 (9–72). The right ventricular dimension decreased in 173 pts (80.4%) (Table 1). Table 1 Parameter Before ASD closure 36 months after ASD closure p value Time of exercise (min) 12.1±5.2 18.6±4.3 <0.001 VO2 peak (ml/kg/min) 10.2±4.7 14.8±4.2 <0.001 SF36q scale 0–100 37.3±22.3 79±29.5 <0.001 Right atrial area (cm2) 20.1±1.7 14.7±1.5 <0.001 Right ventricular area (cm2) 18.1±1.4 12.2±1.5 <0.001 Conclusions ASD closure in patients with borderline shunt resulted in a significant and long-term clinical and hemodynamic improvement after percutaneous treatment.


Circulation ◽  
1979 ◽  
Vol 60 (1) ◽  
pp. 91-100 ◽  
Author(s):  
W Bommer ◽  
L Weinert ◽  
A Neumann ◽  
J Neef ◽  
D T Mason ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document