Knee arthrodesis with an intramedullary nail: a retrospective study

2008 ◽  
Vol 16 (7) ◽  
pp. 645-650 ◽  
Author(s):  
Jeroen De Vil ◽  
Karl Fredrik Almqvist ◽  
Philippe Vanheeren ◽  
Barbara Boone ◽  
René Verdonk
2020 ◽  
Vol 86 (2) ◽  
pp. 33-38
Author(s):  
Marcin Para ◽  
◽  
Paweł Bartosz ◽  
Maciej Kogut ◽  
Gracjan Suchodolski ◽  
...  

Introduction. Complications after arthroplasty often result in irreversible disability. In some cases, for the extremity to be salvaged, permanent knee joint arthrodesis is a last-chance procedure. Modular implant design simplifies surgical technique and knee arthrodesis without bone-on-bone contact, immediately provides full weight bearing and restores limb length and alignment. Puropose. The aim of this article was to perform a clinical evaluation of patients after knee arthrodesis with a dedicated modular intramedullary nail without bone-on-bone contact after a failed infected total knee arthroplasty. Methods. Between 2017 and 2021, 17 patients were treated with knee arthrodesis with a modular nail after a septic complication of total knee arthroplasty. Clinical evaluation of 15 patients was obtained during a follow-up visit, including: the pain severity using the Visual Analog Scale (VAS), physical function using the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) and Oxford Knee Score, gait independence, and the shortening of the affected limb in relation to the other one. Results. The mean follow-up duration was 1.4 years. The group included 11 women and 4 men with an average of 69.3 (57–84) years. All nails were cemented. There was one recurrence of infection. The mean VAS pain score was 2.73, also 4 patients felt no pain at all. The average functional score on the WOMAC scale was 36.4 (14–60) and for the Oxford Knee Score was 26.5 (15–41). Each patient achieved an independent gait. All patients reported the necessity of use of crutches outside home. The average limb shortening was 2.05 cm (0.5–3.0). In addition, 14 of the 15 patients positively evaluated the procedure results and if they had to, they would again decide on this form of treatment. During follow-up, no complication or problems with implants used were observed. Conclusions. Knee arthrodesis with modular nail offers an acceptable functional result and gives a chance of salvaging a limb in complex septic complications of TKA.


2005 ◽  
Vol 20 (6) ◽  
pp. 703-708 ◽  
Author(s):  
John R. Crockarell ◽  
Marc J. Mihalko

2013 ◽  
Vol 19 (4) ◽  
pp. 197-201
Author(s):  
Al. Șerban ◽  
V. Botnaru ◽  
R., Turcu ◽  
B. Obadă ◽  
St. Anderlik

Abstract Background: The gold standard treatment for complex fractures of tibial shaft is the reamed interlocking intramedullary nail. There has been some controversies about dynamization of statically locked nail, and some authors recommend routine dynamization for promotion of healing. This study evaluates the treatment of complex fractures of tibia shaft with static and dynamic interlocking intramedullary nail method. Methods: In this retrospective study, we studied 100 patients treated in Clinical Emergency Hospital Constanta between April 2012 - July 2013 diagnosed with tibia and fibula shaft fractures. They were treated by external fixation, and intramedullary nail. The intramedullary nail was blocked distally static or dynamic. Results: All patients achieved union during 12-18 weeks. The need of dynamization was required at 23 patients after 10 weeks from osteosynthesis. No significant complication was observed in our patients. Alignment of tibial fracture was perfect in all patients without any shortening and rotation. Conclusion: Locked intramedullary nailing is the treatment of choice for fractures of the tibial shaft.


The Knee ◽  
2017 ◽  
Vol 24 (5) ◽  
pp. 1240-1246 ◽  
Author(s):  
Max J. Friedrich ◽  
Jan Schmolders ◽  
Matthias D. Wimmer ◽  
Andreas C. Strauss ◽  
Milena M. Ploeger ◽  
...  

2016 ◽  
Vol 26 (8) ◽  
pp. 907-914 ◽  
Author(s):  
Nima Razii ◽  
Ammar M. I. Abbas ◽  
Rahul Kakar ◽  
Sanjeev Agarwal ◽  
Rhidian Morgan-Jones

Sign in / Sign up

Export Citation Format

Share Document