mechanical complications
Recently Published Documents


TOTAL DOCUMENTS

362
(FIVE YEARS 146)

H-INDEX

24
(FIVE YEARS 5)

Medicina ◽  
2021 ◽  
Vol 58 (1) ◽  
pp. 10
Author(s):  
Tommaso Grandi ◽  
Luca Signorini

(1) Background and Objectives. Currently, there are no definitive long-term data about clinically significant difference in the failure of prosthesis and implant or marginal bone loss related to the rehabilitation of the completely edentulous mandible by all-on-four treatment concept. The main aim of present investigation was to report the long-term outcomes (10-years follow-up) of complete-arch mandibular rehabilitations based on the all-on-four concept. (2) Materials and Methods. Patients in need of extractions of teeth due to the occurrence of caries and/or severe periodontal disease and patients presented with edentulous mandibles were enrolled to the study. A total of 96 participants (mean follow-up period after intervention of 3185.2 days) were enrolled in the study. Participants were evaluated at the first visit, 10 days after intervention and every year after the intervention. Implant and prosthesis survival, bone loss and both local biological and mechanical complications were evaluated during the follow-up period. (3) Results. An implants’ survival rate of 97.9% was observed at the end of the follow-up period. Biological complications were reported in 19.8% of patients, whereas mechanical complications were reported in 27.1% of cases. The average marginal bone level at baseline was −0.03 mm. A significant marginal bone loss was observed after 10-years follow-up (2.5 mm). Binary logistic regression analysis showed significant association between smoke and both marginal bone loss and local biological complications. Lastly, a significant association was observed between bruxism and mechanical complications. (4) Conclusions. The high implant and prosthesis survival rate and the moderate incidence of biological and mechanical complications observed in present investigation can be associated to several factors such as high implant primary stability, prosthetic design, and control of the occlusal forces.


Author(s):  
Kieran J. Moore ◽  
David Greencorn ◽  
Nadine Smith ◽  
Joanne M. Langley ◽  
Ketan Kulkarni

Abstract Background: Despite the numerous advantages of central venous catheters (CVCs), they have been associated with a variety of complications. Surveillance for mechanical complications of CVCs is not routine, so the true incidence and impact of this adverse patient outcome remains unclear. Setting and methods: Prospectively collected CVC data on mechanical complications were reviewed from a centralized database for all in-hospital patient days at our tertiary-care hospital from January 2001 to June 2016 in patients aged <19 years. Patient demographics, CVC characteristics, and rates of mechanical complications per 1,000 days of catheter use were described. Results: In total, 8,747 CVCs were placed in 5,743 patients during the study period, which captured 780,448 catheter days. The overall mechanical complication rate was 6.1 per 1,000 catheter days (95% confidence interval [CI], 5.9–6.3). The highest complication rates were in nontunneled lines; this was consistent throughout the 15-year study period. Also, 521 CVCs (∼6%) were removed due to mechanical complications before therapy termination. Catheters with tip location in the superior vena cava or right atrium had the fewest complications. Conclusions: Mechanical complications of CVCs are a common and significant event in the pediatric population. We propose that CVC-associated mechanical complications become a routinely reported patient safety outcome.


2021 ◽  
Vol 50 (1) ◽  
pp. 508-508
Author(s):  
Erica Chemtob ◽  
David Kauffman ◽  
Connie Nguyen ◽  
Allison Hu ◽  
Raymond Pla ◽  
...  

Neurosurgery ◽  
2021 ◽  
Vol Publish Ahead of Print ◽  
Author(s):  
Darryl Lau ◽  
Rushikesh S. Joshi ◽  
Alexander F. Haddad ◽  
Vedat Deviren ◽  
Christopher P. Ames

Author(s):  
Holzknecht Magdalena ◽  
Klug Gert ◽  
Metzler Bernhard ◽  
Reinstadler J. Sebastian

2021 ◽  
Author(s):  
Rot Sergej ◽  
Goelz Leonie ◽  
Arndt Holger ◽  
Gutowski Pawel ◽  
Meier Ullrich ◽  
...  

Abstract Background Mechanical obstruction of ventriculoperitoneal shunt (VPS) during the first year after shunt implantation is a common complication and is widely described in the literature. In this paper, we evaluated the suitability of the shuntography for the diagnosis of mechanical complications of the VPS in patients with idiopathic normal pressure hydrocephalus (iNPH). Methods We retrospectively identified 49 patients with pathologic shuntography over of a period of 20 years in our hospital. The percentage of procedure-associated complications was determined. Results Ninety-eight percent (n = 48) of the patients who underwent shuntography showed clinical and radiographic signs of underdrainage prior to examination. Shuntography revealed mechanical complications of the VP shunt in 37% (n = 18) as a cause of clinical deterioration and following revision operation. During shuntography, mechanical obstruction was discovered in 78% (n = 14) and disconnection of shunt components in 22% (n = 4). In the obstruction group, in 50% (n = 7) the closure was detected in the ventricular catheter, in 29% (n = 4) in the distal catheter of the VPS, and in 21% (n = 3) in both sides of the VPS. In the case of an inconspicuous shuntography (63%, n = 31), the patients received symptomatic therapy (32%, n = 10) or re-adjustment of the valve setting (68%, n = 21). Fifty-seven percent of the patients who underwent surgical treatment improved clinically by at least one point according to the Kiefer score. Conclusion Shuntography can produce valuable clinical information uncovering mechanic complications after implantation VPS in patients with idiopathic normal-pressure hydrocephalus. Patients with mechanical complications of their VPS needed revision surgery and showed clinical benefit after treatment.


2021 ◽  
Vol 22 (1) ◽  
Author(s):  
Carlos Hernández-Pascual ◽  
José Ángel Santos-Sánchez ◽  
Juan Manuel García-González ◽  
Carlos Fernando Silva-Viamonte ◽  
Carmen Pablos-Hernández ◽  
...  

Abstract Background Few publications have assessed long-term results of distal locking of short endomedullary nails for extracapsular hip fracture. Virtually all of them focus on immediate differences. Criteria for the use of static or dynamic locking are unclear in most nailing systems, and use is advised in unstable fracture patterns or with risk of bell-clapper effect, but often influenced by the “orthopaedic school”. Materials and methods This is a historical cohort study on patients diagnosed and operated in 2014 and followed up until endpoint, considered as consolidation or major complication, plus evaluation of overall long-term survival. They were categorised as static distal locking (ST) or dynamic distal locking (DN). Both are comparable, except for all stable pre-operative classifications, Fracture Mobility Score (FMS) at discharge, and immediate post-operative loading, all of which were in favour of DN. Results Consolidation took place in > 95% of patients, with a non-statistically significant delay trend in ST. Less than 6% in both ST and DN had major complications, with no differences. Most cases suffered early cut-out. Significant fracture collapse was the most frequent minor complication. There were more statistically significant minor and total complications in ST. Infection, without differences, can precede cut-out. Lateral thigh pain was similar and could be related to back-out. In DN, 21.1% of cases were truly dynamised. We did not find differences in mobility or in long-term survival. Conclusions Any type of distal locking seems to be safe for consolidation, despite a slightly longer consolidation time in static locking. Early cut-out was the main complication, while others were very infrequent, which is an advantage over helical blade devices. There was a higher rate of minor and overall mechanical complications in ST, but infection and lateral thigh pain were similar. Most non-traumatic mechanical complications occurred around 5–6 weeks. About one in five of the DN truly dynamised, with all cases occurring before 8 weeks. Mobility until endpoint and overall long-term survival were not influenced by the locking mode used. Level of evidence Therapeutic study, level 2b.


Life ◽  
2021 ◽  
Vol 11 (11) ◽  
pp. 1245
Author(s):  
Anna Baudry ◽  
Anne-Sophie Mariet ◽  
Eric Benzenine ◽  
Valentin Crespy ◽  
Chloé Bernard ◽  
...  

Background: There are still gaps regarding the impact of the nationwide lockdown on non-COVID-19 emergency hospitalizations. This study aims to describe the trends in hospitalizations for cardiovascular surgical emergencies in France, before, during and after the first lockdown. Materials and Methods: All adults admitted for mechanical complications of myocardial infarction (MI), aortic dissection, aortic aneurysm rupture, acute and critical limb ischemia, circulatory assistance, heart transplantation and major amputation were included. This retrospective cohort study used the French National Hospital Discharge database. The numbers of hospitalizations per month in 2020 were compared to the previous three years. Results: From January to September 2020, 94,408 cases of the studied conditions were reported versus 103,126 in the same period in 2019 (-8.5%). There was a deep drop in most conditions during the lockdown, except for circulatory assistance, which increased. After the lockdown, mechanical complications of MI and aortic aneurysm rupture increased, and cardiac transplantations declined compared with previous years. Conclusion: We confirmed a deep drop in most cardiovascular surgical emergencies during the lockdown. The post-lockdown period was characterized by a small over-recovery for mechanical complications of MI and aortic aneurysm rupture, suggesting that many patients were able to access surgery after the lockdown.


2021 ◽  
Author(s):  
Yao Zhao ◽  
Beiyu Xu ◽  
Longtao Qi ◽  
Chunde Li ◽  
Zhengrong Yu ◽  
...  

Abstract Background The treatment of adult spinal deformity (ASD) remains a significant challenge, especially in elderly patients. This study aimed to evaluate the outcomes of the S2AI screw technique in the treatment of severe spinal sagittal imbalance with a minimum 2-year follow-up. Methods From January 2015 to December 2018, 23 patients with severe degenerative thoracolumbar kyphosis who underwent placement of S2AI screws for long segment fusion were retrospectively reviewed. Patients were divided into group A (no mechanical complications, 13 cases) and group B (with mechanical complications, 10 cases) according to the occurrence of mechanical complications at the last follow-up. Radiographic parameters were compared between groups preoperatively, 1 month postoperatively, and at the last follow-up. Risk factors for mechanical complications were analyzed. Results The incidence of mechanical complications was 43.5%, and the revision rate was 17.4%. At 1 month postoperatively, sagittal correction was better in group A than in group B (P<0.05). The lumbar lordosis (LL), pelvic incidence minus lumbar lordosis (PI-LL), T1 pelvic angle (TPA), and sagittal vertical axis (SVA) of both groups at the last follow-up were significantly different from corresponding values at 1 month postoperatively (P<0.05), and the sagittal correction was partially lost. Pearson correlation analysis revealed that the occurrence of mechanical complications was associated with sacral slope (SS), LL, PI-LL, and global alignment and proportion (GAP) score at 1 month postoperatively. Conclusion A high incidence of mechanical complications was observed in long-segment corrective surgery with the S2AI screw technique for severe spinal sagittal imbalance. Inadequate sagittal correction is a risk factor for the development of mechanical complications.


2021 ◽  
Vol 16 (1) ◽  
Author(s):  
Xiangyao Sun ◽  
Wenzhi Sun ◽  
Siyuan Sun ◽  
Hailiang Hu ◽  
Sitao Zhang ◽  
...  

Abstract Background To achieve the proper sagittal alignment, previous studies have developed different assessment systems for adult degenerative scoliosis (ADS) which could help the spine surgeon in making treatment strategies. The purpose of our study is to evaluate whether Roussouly classification or global alignment and proportion (GAP) score is more appropriate in the prediction of mechanical complications after surgical treatment of ADS. Methods ADS patients who received long segmental fusion in the treatment during the period from December 2016 to December 2018 were evaluated in this study. Basic information and radiologic measurements were collected for analysis. Patients were divided into two groups according to occurrence or absence of mechanical complications for comparison. Mechanical complications included proximal junctional kyphosis (PJK), proximal junctional failure (PJF). GAP categories divided GAP score into proportioned spinopelvic position, moderately disproportioned position, and severely disproportioned position according to the cut-off values. The correlation between evaluation systems and mechanical complications was analyzed through a logistic regression model via stepwise backward elimination based on the Wald statistics. Receiver operator characteristic (ROC) curve was used to determine the predictability of the evaluation systems in the occurrence of mechanical complications and calculate their cut-off value. Area under the curve (AUC) was used to evaluate the validity of the thresholds. Results A total of 80 patients were included in this study. There were 41 patients in mechanical complication group and 39 patients in no mechanical complication group. GAP score (P = 0.008) and GAP categories (P = 0.007) were positively correlated with mechanical complications; Roussouly score was negatively correlated with mechanical complications (P = 0.034); GAP score was positively correlated with PJK (P = 0.021); Roussouly score was negatively correlated with implant-related complications (P = 0.018); GAP categories were correlated with implant loosening (P = 0.023). Results of ROC showed that GAP score was more effective in predicting PJK (AUC = 0.863) and PJF (AUC = 0.724) than Roussouly score; GAP categories (AUC = 0.561) was more effective than GAP score (AUC = 0.555) in predicting implant-related complications. Conclusions Roussouly classification could only be a rough estimate of optimal spinopelvic alignment. Quantitative parameters in GAP score made it more effective in predicting mechanical complications, PJK and PJF than Roussouly classification.


Sign in / Sign up

Export Citation Format

Share Document