Locking plate versus non-locking plate in open-wedge high tibial osteotomy: a meta-analysis

2015 ◽  
Vol 25 (3) ◽  
pp. 808-816 ◽  
Author(s):  
Jae Hwi Han ◽  
Hyun Jung Kim ◽  
Jae Gwang Song ◽  
Jae Hyuk Yang ◽  
Ryuichi Nakamura ◽  
...  
2009 ◽  
Vol 10 (9) ◽  
pp. 689-695 ◽  
Author(s):  
Hai-ning Zhang ◽  
Jie Zhang ◽  
Cheng-yu Lv ◽  
Ping Leng ◽  
Ying-zhen Wang ◽  
...  

2021 ◽  
Vol 22 (1) ◽  
Author(s):  
Junya Itou ◽  
Umito Kuwashima ◽  
Masafumi Itoh ◽  
Koichi Kuroda ◽  
Yasuharu Yokoyama ◽  
...  

Abstract Background The neurovascular bundle containing the deep peroneal nerve has a potential risk of injury during open-wedge high tibial osteotomy (OWHTO), particularly due to drilling for bicortical fixation at distal screw holes. Therefore, monocortical fixation is recommended for distal fixation of a long locking plate as long as good stability is ensured. The purpose of this study was to analyse the biomechanical properties of monocortical fixation of distal locking screws for OWHTO. Methods Three-dimensional models of bone and fixation materials simulating OWHTO were created using computed tomographic data of patients and material data of a T-shaped long locking plate and screws. Three of the four distal screws of the locking plate were chosen for a bicortical fixation or monocortical fixation procedure. In addition, loss of correction was assessed by measuring the medial proximal tibial angle (MPTA) in patients who underwent OWHTO with two bicortical and two monocortical distal fixation screws at 1 month and 1 year after surgery. Results No significant differences in stress were observed in either the normal or osteoporotic bone model between the monocortical and bicortical fixation models, including in the area of the lateral hinge at the osteotomy site. Furthermore, there were no significant differences in MPTA between the early post-operative period and 1-year follow-up. Conclusions The monocortical fixation method for three distal screws of the locking plate did not worsen the mechanical properties of fixation for OWHTO using a long locking plate with four proximal and four distal screws. In actual surgery, the number of distal bicortical screws should be reduced based on the patient’s condition, taking into account the risk of lateral hinge fracture and unexpected surgical complications. Using at least two bicortical screws would be practical considering the various factors related to reduced fixing ability.


2020 ◽  
Vol 7 (2) ◽  
pp. 55-60
Author(s):  
Mahmood Jabalameli ◽  
◽  
Sepehr Khosravi ◽  
Delaram Delbari ◽  
Abolfazl Bagheri Fard ◽  
...  

Background: High Tibial Osteotomy (HTO) is an approved surgical technique for varus knee deformity. For open wedge HTO multiple fixation methods and devices have been used. Advantages and disadvantages of these methods and devices are reported in various studies. Few studies have been conducted on use and final outcome of correction of varus knee deformity by implementation of non locking plates and benefits of this method is not fully evaluated. Objectives: To assess clinical and radiographic features of non-locking 4.5 millimeter L-buttress plate and T-buttress plate, which is used in open wedge High Tibial Osteotomy (HTO), and to find out whether this device is efficient enough or not. Methods: This cross-sectional study was conducted on 39 patients with tibial deformity recruited from a referral orthopedic hospital in Iran. Patients’ information, including their baseline characteristics, Range of Motion (ROM) of the knee, comorbidities, time of weight-bearing, union time in x-ray, graft type, and time of follow-up were reported at two stages: before and after the operation. Radiographic images were taken from their legs in both stages. Although different surgeons operated on the cases, they all used the same method. After the surgery, they were checked up in 2, 6, 12, and 24 weeks and a second alignment view was taken from the patients. Results: Thirty-nine patients underwent surgery for the correction of genu varus deformity and the follow-up time was between 6-48 months. There was no case of non-union and the ROM was perfectly restored in all the patients. Conclusion: Although the rate of the success in the use of the locking plate in HTO is higher, the use of a 4.5-mm non-locking plate seems to have decent results, too; therefore, it could be used as an alternative yet functional fixation tool in HTO.


2017 ◽  
Vol 2017 ◽  
pp. 1-9 ◽  
Author(s):  
Seung-Beom Han ◽  
Hyun Jung Kim ◽  
Dae-Hee Lee

Background. It is unclear whether computer navigation can improve the accuracy and reliability of targeted lower limb alignment correction following open-wedge high tibial osteotomy (HTO). This meta-analysis was designed to compare the accuracy and reliability of limb alignment correction between computer navigated and conventional open-wedge HTOs. Methods. Studies that compared postoperative coronal alignment, including mechanical axis (MA) and weight bearing line (WBL) ratio, outliers of alignment correction, and change in tibial posterior slope, following open-wedge HTO performed using computer navigated and conventional methods were included. Results. Ten studies were included in the meta-analysis. The MA (0.93°; 95% confidence interval [CI]: 0.45–1.41°; P<0.001) and WBL ratio (1.5%; 95% CI: 0.03–2.98%; P=0.048) were significantly greater for computer navigated HTO than for conventional HTO. Outliers of alignment correction after surgery were significantly lower in patients who underwent computer navigated HTO than in those who underwent conventional HTO (odds ratio: 0.25; 95% CI: 0.08–0.79; P=0.02). Changes in posterior tibial slope from before to after surgery, however, were similar for the two approaches. Conclusion. Computer navigated HTO resulted in slightly more valgus postoperative alignment and effectively reduced outliers of alignment correction but had no effect on change in posterior tibial slope when compared with conventional HTO.


2019 ◽  
Vol 20 (1) ◽  
Author(s):  
Jun-Ho Kim ◽  
Hyun-Jung Kim ◽  
Haluk Celik ◽  
Joo-Hwan Kim ◽  
Dae-Hee Lee

Sign in / Sign up

Export Citation Format

Share Document