scholarly journals 24-Month Registry Results on Drug-Coated Balloon Angioplasty Below the Knee: Strong Enough Evidence to Convince the Sceptics?

2020 ◽  
Vol 44 (1) ◽  
pp. 19-20
Author(s):  
Ulf Teichgräber
2020 ◽  
Vol 62 ◽  
pp. 387-396
Author(s):  
Vicente Riambau ◽  
Francisco Acín ◽  
Mariano Juan de Blas ◽  
Manuel Alonso ◽  
Antonio Giménez-Gaibar ◽  
...  

2021 ◽  
Vol 77 (18) ◽  
pp. 1150
Author(s):  
Waqas Ullah ◽  
Mohamed Zghouzi ◽  
Bachar Ahmad ◽  
Yasar Sattar ◽  
Zeeshan Sattar ◽  
...  

2019 ◽  
Vol 7 ◽  
pp. 2050313X1983415
Author(s):  
Taketsugu Tsuchiya ◽  
Minako Oda ◽  
Takaaki Takamura ◽  
Katsuhide Kitagawa ◽  
Koji Kajinami ◽  
...  

Early 80s male with intermitted claudication underwent endovascular therapy for atherosclerotic stenosis at left external iliac artery and middle of superficial femoral artery. Patient also had chronic atrial fibrillation, diabetes mellitus, and hypertension. After stent deployment for external iliac artery lesion, a short superficial femoral artery lesion was performed with angioplasty using drug-coated balloon. The drug-coated balloon angioplasty resulted in 50% residual stenosis with linear dissection; however, provisional stenting was not performed as decent ante-grade blood flow allowed 10 extra minutes. Medication involved ongoing use of aspirin 100 mg and rivaroxaban 15 mg. Angiography post 3 months from index procedure showed external iliac artery and superficial femoral artery patency and healing of intimal dissection at superficial femoral artery lesion was estimated by intravascular ultrasonography. In angioscopy findings, red thrombus was seen in dissection cavity.


2003 ◽  
Vol 10 (5) ◽  
pp. 987-993 ◽  
Author(s):  
Thomas Zeller ◽  
Ulrich Frank ◽  
Karlheinz Bürgelin ◽  
Uwe Schwarzwälder ◽  
Peter-Christian Flügel ◽  
...  

Purpose: To evaluate the efficacy and safety of a new atherectomy device for the treatment of infragenicular lesions in arteries with a reference diameter of at least 2.5 mm. Methods: Twenty-seven below-the-knee lesions in 17 patients (12 men; mean age 69±12 years) with chronic peripheral arterial occlusive disease were treated with directional atherectomy. The target lesion was in the popliteal artery (segment 3) in 2 (7%) cases, the tibioperoneal trunk in 12 (44%), the peroneal artery in 8 (30%), the anterior tibial artery in 2 (7%), and the posterior tibial artery in 3 (11%). Six (22%) of the lesions were in-stent stenoses. The mean diameter stenosis was 87%±9%, and the mean lesion length was 34±24 mm. Results: All but 2 (7%) of the lesions could be treated successfully (residual stenosis <30%) with the atherectomy catheter (93% technical success) using an average of 5±2 (range 1–10) passes of the device. Six lesions (22%) were treated after predilation and 21 (78%) with primary atherectomy. In 8 (30%) lesions, additional balloon angioplasty was performed. The 2 failures were in heavily calcified lesions through which the device could not pass despite predilation. The mean diameter stenosis after atherectomy was 14%±22% (range 0%–90%); after additional balloon angioplasty, the mean residual stenoses reduced to 12%±21% (range 0%–100%). One (6%) of the 2 patients who failed atherectomy sustained a thrombotic occlusion of the target vessel. This complication was treated successfully with local lysis, but the vessel reoccluded 3 days later; a stent was implanted. The mean ankle-brachial index increased from 0.50±0.27 to 0.86±0.40 before discharge. Conclusions: Below-the-knee native vessel lesions and in-stent restenoses with a diameter of at least 2.5 mm can be treated successfully and safely with this new atherectomy catheter. Additional balloon angioplasty was necessary in only a few cases.


2018 ◽  
Vol 71 (8) ◽  
pp. 620-627 ◽  
Author(s):  
Salvatore Cassese ◽  
Bo Xu ◽  
Seiji Habara ◽  
Harald Rittger ◽  
Robert A. Byrne ◽  
...  

2022 ◽  
pp. 112972982110701
Author(s):  
Yunfeng Li ◽  
Zhenwei Shi ◽  
Yunyun Zhao ◽  
Zhanjiang Cao ◽  
Zhengli Tan

Purpose: To compare all-cause mortality and primary patency with drug-coated balloon angioplasty (DCBA) compared with plain balloon angioplasty (PBA) in people with hemodialysis-related stenosis. Materials and methods: PubMed, Embase, and Cochrane Library databases were searched from November 1966 to February 2021 to identify randomized controlled trials (RCTs) that assessed the use of DCBA versus PBA for stenosis in hemodialysis circuits. Data extracted from the articles were integrated to determine all-cause mortality, target lesion primary patency (TLPP), circuit access primary patency (CAPP), 30-day adverse events, and technical success for the two approaches. We performed meta-analysis on these results using a fixed-effects model to evaluate odds ratios (ORs) and 95% confidence intervals (CIs) where I2 < 50% in a test for heterogeneity, or a random-effect model if otherwise. Sensitivity and subgroup analyses were also performed. Results: Sixteen RCTs of 1672 individuals were included in our meta-analysis, of which 839 individuals received DCBA and 833 received PBA. The pooled outcome showed no statistical difference between DCBA and PBA in all-cause mortality at 6 months (OR = 1.29, 95% CI = 0.72–2.32, p = 0.39, I2 = 4%), 12 months (OR = 1.02, 95% CI = 0.68–1.53, p = 0.91, I2 = 0%), and 24 months (OR = 1.50, 95% CI = 0.87–2.57, p = 0.15, I2 = 0%), 30-day adverse events (OR = 1.09, 95% CI = 0.30–3.98, p = 0.90, I2 = 66%), and technical success (OR = 0.18, 95% CI = 0.02–1.92, p = 0.16, I2 = 65%). The DCBA had significantly better outcomes versus PBA in TLPP at 6 months (OR = 2.37, 95% CI = 1.84–3.04, p < 0.001, I2 = 44%) and 12 months (OR = 1.77, 95% CI = 1.22–2.56, p = 0.002, I2 = 56%), and CAPP at 6 months (OR = 2.07, 95% CI = 1.21–3.54, p = 0.008, I2 = 67%) and 12 months (OR = 1.66, 95% CI = 1.29–2.15, p < 0.001, I2 = 0%). Conclusion: In hemodialysis circuit stenosis, DCBA appears to have similar safety but greater efficacy than PBA.


Sign in / Sign up

Export Citation Format

Share Document