Impact of measured total keratometry versus anterior keratometry on the refractive outcomes of the AT TORBI 709-MP toric intraocular lens

Author(s):  
Antoine Levron ◽  
Hussam El Chehab ◽  
Emilie Agard ◽  
Roman Chudzinski ◽  
Jeremy Billant ◽  
...  
2021 ◽  
Author(s):  
Meng-Yin Lin ◽  
Yun-Dun Shen ◽  
Hsin-Yuan Tan ◽  
I-Jong Wang ◽  
I-Chan Lin

Abstract Background: Both femtosecond laser-assisted arcuate keratotomy (FS-AK) and toric intraocular lens (IOL) implantation were effective in correction for eyes with corneal astigmatism. The objective of this study was to evaluate the postoperative refractive outcomes of patients receiving femtosecond laser-assisted cataract surgery (FLACS) with FS-AK and patients receiving standard phacoemulsification with toric intraocular lens implantation Methods: This retrospective study reviewed the postoperative outcome of patients undergoing FLACS with FS-AK (FS-AK group) and patients undergoing standard phacoemulsification with toric IOL implantation (toric IOL group). The main outcome measures were bare and corrected visual acuities, keratometric and refractive astigmatism, and vector analysis.Results: The FL-AK group included 41 eyes with preoperative keratometric astigmatism of −1.64 diopters (D) ± 0.42 (standard deviation), and the toric IOL group included 53 eyes with preoperative keratometric astigmatism of −2.29 ± 0.91 D (P < 0.001). Postoperative refractive astigmatism was comparable between the two groups. Postoperative bare vision was significantly better (P = 0.005) and corrected visual acuity was marginally better in the toric IOL group than in the FS-AK group (P = 0.051). The absolute angles of error were 9.95 ± 9.57 degrees and 5.08 ± 4.94 degrees (P = 0.02) in the FS-AK and toric IOL groups, respectively.Conclusion: Both FLACS with FS-AK and standard phacoemulsification with toric IOL implantation represent safe and effective methods for astigmatism correction at the time of cataract surgery. Standard phacoemulsification with toric IOL implantation achieves better visual outcome than combined FLACS and FS-AK at 6-month follow up.


2020 ◽  
pp. 112067212096058
Author(s):  
Erika Fernández-Muñoz ◽  
Jorge Blanco-Gómez ◽  
Rafael Vázquez-Rojas ◽  
Katia Camargo-Ibarias ◽  
Martha Massaro-Corredor ◽  
...  

Purpose: To determine the refractive stability of patients with keratoconus and cataracts after the implantation of a toric intraocular lens. Methods: This is a cross-sectional, retrospectivestudy. Clinical records from patients with non-progressive keratoconus and cataracts that underwent non-complicated phacoemulsification with toric IOL implantation were reviewed. Mean keratometry (Km), refractive cylinder (RC), spherical equivalent (SE), steeper keratometry (K), and axis were evaluated at the 1-month, 6-month, 12-month, and 24-month follow-up visits. Results: Fifty-four eyes from 41 patients were included. Thirty-seven (68.5%) female and 17 (31.5%) male patients, with a mean age of 67.52 ± 8.22. Refractive cylinder at postoperative 30 days was −1.61 ± 1.23, 6-month −1.22 ± 0.80, 12-month −1.10 ± 0.83 and 24-month visit after surgery was −1.37 ± 0.77( p = 0.290). SE at the 30-day visit was −0.82 ± 1.90, 6-month −0.64 ± 1.23, 12-month −0.78 ± 1.91 and at 24-month postoperative visit −1.02 ± 1.87 ( p = 0.210). Km value at the 1-month visit was 47.23 ± 1.95, 6-month 47.87 ± 1.61, 12-month 46.39 ± 2.52 and 24-month postoperative visit 46.92 ± 1.26 ( p = 0.877). The steeper K axis in the 30-day control was 78.53 ± 30.12, 6-month 77.29± 37.68, 1-year 93.13 ± 62.42, 24-month 67.31 ± 38.49 ( p = 0.632). Conclusions: Our findings suggest a low variation in the refractive outcome for patients with mild and moderate keratoconus and cataracts, without evident progression signals, a demonstrated keratoconus clinical stability. No statistically significant postoperative changes in the refractive cylinder, SE, mean K, and steeper K axis were observed, which suggests good predictability for toric IOL implant.


2021 ◽  
pp. 30-41
Author(s):  
Ladislav Viktor Nováček ◽  
Marie Němcová ◽  
Kateřina Tyx ◽  
Kristýna Lahodová ◽  
Leoš Rejmont ◽  
...  

Objectives: The aim of this study was to assess the clinical outcomes, predictability of results, efficiency of astigmatism correction, and rotational stability of the Bi-Flex 677TAY (Medicontur Medical Engineering Ltd., Zsámbék, Hungary) monofocal toric intraocular lens (IOL) designed for cataract patients with astigmatism. Methods: The IOLs were implanted either mono- or binocularly, following routine cataract surgery. Visual and refractive outcomes, as well as off-axis rotation were assessed throughout a 1-year follow-up period. All clinical data for this work were collected retrospectively. Vector analysis based on the Alpins method was performed to assess the efficiency of astigmatism correction. Results: No complications or adverse events occurred during surgery or the follow-up period. IOL implantation brought 88% of eyes into the ±0.50 D, and 100% into the ± 1.00 D range compared to the target spherical equivalent refraction, emmetropia. Astigmatism correction brought similar results: 94% of eyes had a residual cylindrical error of not higher than ±0.50 D, and 97% were within ±1.00 D. Vector analysis resulted in a correction index of 0.96 and a difference vector of 0.17. Both refractive and visual outcomes showed long-term stability. During the 12-month follow-up period, no eyes had a rotation of >5°. Absolute rotation after 1 year was 1.42 ± 1.89° (median = 0°), while signed rotation was 1.06 ± 2.12° (median = 0°). Conclusion: The Bi-Flex 677TAY monofocal toric IOL, designed by Medicontur Medical Engineering Ltd., represents an efficient and safe solution for cataract patients with astigmatism. Clinical and refractive outcomes are predictable, and rotational stability ensures long-term visual comfort.