Determination of the Mass Absorption Coefficient in Two-Layer Cr/Co Thin Film Systems by the X-Ray Fluorescence Method

2020 ◽  
Vol 86 (6) ◽  
pp. 1048-1052
Author(s):  
E. A. Cherniaeva ◽  
A. A. Knyazeva ◽  
E. O. Zimina ◽  
I. S. Belyakova ◽  
N. I. Mashin
1992 ◽  
Vol 7 (4) ◽  
pp. 194-196 ◽  
Author(s):  
Stefano Battaglia ◽  
Marco Franzini ◽  
Leonardo Leoni

AbstractThis paper describes a new method for the simultaneous determination of mineral composition, mass thickness and mass absorption coefficient of a thin layer of a crystalline substance deposited on a crystalline substrate.The samples were deposited on membrane disc filters, consisting of mixtures of cellulose acetate and cellulose nitrate. Quantitative results are achieved by measuring the diffraction intensity of the analyte and the attenuation of a reflection of the crystalline material supporting the deposited sample. The mean accuracy of the analysis was found to be: ≈ 3% for mass thickness, ≈ 1% for mass absorption coefficient and ≈ 4% for quantitative mineralogical determination.


1990 ◽  
Vol 34 ◽  
pp. 325-335 ◽  
Author(s):  
Steve J. Chipera ◽  
David L. Bish

AbstractThe mass absorption coefficient is a useful parameter for quantitative characterization of materials. If the chemical composition of a sample is known, the mass absorption coefficient can be calculated directly. However, the mass absorption coefficient must be determined empirically if the chemical composition is unknown. Traditional methods for determining the mass absorption coefficient involve measuring the transmission of monochromatic X-rays through a sample of known thickness and density. Reynolds (1963,1967), however, proposed a method for determining the mass absorption coefficient by measuring the Compton or inelastic X-ray scattering from a sample using Mo radiation on an X-ray fluorescence spectrometer (XRF). With the recent advances in solid-state detectors/electronics for use with conventional powder diffractometers, it is now possible to readily determine mass absorption coefficients during routine X-ray diffraction (XRD) analyses.Using Cu Kα radiation and Reynolds’ method on a Siemens D-500 diffractometer fitted with a Kevex Si(Li) solid-state detector, we have measured the mass absorption coefficients of a suite of minerals and pure chemical compounds ranging in μ/ρ from graphite to Fe-metal (μ/ρ = 4.6-308 using Cu Kα radiation) to ±4.0% (lσ). The relationship between the known mass absorption coefficient and the inverse count rate is linear with a correlation coefficient of 0.997. Using mass absorption coefficients, phase abundances can be determined during quantitative XRD analysis without requiring the use of an internal standard, even when an amorphous component is present.


1990 ◽  
Vol 5 (1) ◽  
pp. 44-47 ◽  
Author(s):  
David L. Wertz

AbstractAn X-ray analysis method has been developed for the quantitative analysis of pyrite (FeS2) in coals and lignites. Requiring neither the use of external or internal references, the method linearly relates diffraction peak area in the absorption corrected X-ray diffractogram obtained from the finely powdered coal to the pyrite abundance. The [311] diffraction peak of pyrite (FeS2) has been used to develop the analysis protocol. The Argonne premium coals have been used as the experimental subjects. The abundance of pyrite in each coal has been measured from the absorption corrected diffractograms, which has been constructed from the experimentally measured diffraction intensities and the mass absorption coefficient of each coal sample. The accuracy (accessed from the figure-of-merit and the net count uncertainty associated with the 1.63 Å pyrite peak) as well as the lower limit of detection for pyrite in these coals is presented. The role of the mass absorption coefficient in the conversion of the measured intensity to the absorption corrected intensity is discussed.


Sign in / Sign up

Export Citation Format

Share Document