measured intensity
Recently Published Documents


TOTAL DOCUMENTS

111
(FIVE YEARS 20)

H-INDEX

15
(FIVE YEARS 1)

Author(s):  
Shawutijiang Sidikejiang ◽  
Philipp Henning ◽  
Philipp Horenburg ◽  
Heiko Bremers ◽  
Uwe Rossow ◽  
...  

Abstract We compare the low-temperature photoluminescence (PL) intensities of a range of GaInN/GaN quantum well (QW) structures under identical excitation conditions, mounting the samples side by side. Normalizing the measured intensity to the absorbed power density in the QWs, we find that low-temperature PL efficiencies of several samples, which show close to 100% IQE in time-resolved PL, saturate at nearly an identical value. Of course, this is strong indicative of being 100% IQE at low temperature for those efficient samples. Using the low-temperature PL efficiency as a ``Reference'', on the other hand, we observe not only the effects of temperature-independent non-radiative losses on the low-temperature IQE, but also are able to determine the IQE of arbitrary samples on an absolute scale. Furthermore, we prove the experimental results by comparing the low-temperature efficiencies of a sample with an initial 100% IQE after intentionally introducing structural defects with argon-implantation.


Sensors ◽  
2021 ◽  
Vol 21 (20) ◽  
pp. 6864
Author(s):  
Leopold Veselka ◽  
Lisa Krainz ◽  
Leonidas Mindrinos ◽  
Wolfgang Drexler ◽  
Peter Elbau

Optical coherence tomography (OCT) is a widely used imaging technique in the micrometer regime, which gained accelerating interest in medical imaging in the last twenty years. In up-to-date OCT literature, certain simplifying assumptions are made for the reconstructions, but for many applications, a more realistic description of the OCT imaging process is of interest. In mathematical models, for example, the incident angle of light onto the sample is usually neglected or a plane wave description for the light–sample interaction in OCT is used, which ignores almost completely the occurring effects within an OCT measurement process. In this article, we make a first step to a quantitative model by considering the measured intensity as a combination of back-scattered Gaussian beams affected by the system. In contrast to the standard plane wave simplification, the presented model includes system relevant parameters, such as the position of the focus and the spot size of the incident laser beam, which allow a precise prediction of the OCT data. The accuracy of the proposed model—after calibration of all necessary system parameters—is illustrated by simulations and validated by a comparison with experimental data obtained from a 1300 nm nswept-source OCT system.


Photonics ◽  
2021 ◽  
Vol 8 (8) ◽  
pp. 314
Author(s):  
Nikolay A. Kalinin ◽  
Elena A. Anashkina ◽  
Olga N. Egorova ◽  
Sergey G. Zhuravlev ◽  
Sergei L. Semjonov ◽  
...  

Coherent propagation of supermodes in a multicore fiber is promising for power scaling of fiber laser systems, eliminating the need for the active feedback system to maintain the phases between the channels. We studied the propagation of broadband pulsed radiation at a central wavelength of 1030 nm in a multicore fiber with coupled cores arranged in a square array. We designed and fabricated a silica multicore fiber with a 5 × 5 array of cores. For controllable excitation of a desired supermode, we developed a beam-forming system based on a spatial light modulator. We experimentally measured intensity and phase distributions of the supermodes, in particular, the in-phase and out-of-phase supermodes, which matched well the numerically calculated profiles. We obtained selective excitation and coherent propagation of broadband radiation with the content of the out-of-phase supermode of up to 90% maintained without active feedback. Using three-dimensional numerical modeling with allowance for a refractive index profile similar to those of the developed fiber, we demonstrated stable propagation of the out-of-phase supermode and collapse of the in-phase supermode at a high signal power.


2021 ◽  
Vol 54 (4) ◽  
Author(s):  
Giuseppe Abbondanza ◽  
Alfred Larsson ◽  
Francesco Carlá ◽  
Edvin Lundgren ◽  
Gary S. Harlow

X-ray diffractometers primarily designed for surface X-ray diffraction are often used to measure the diffraction from powders, textured materials and fiber-texture samples in 2θ scans. Unlike in high-energy powder diffraction, only a fraction of the powder rings is typically measured, and the data consist of many detector images across the 2θ range. Such diffractometers typically scan in directions not possible on a conventional laboratory diffractometer, which gives enhanced control of the scattering vector relative to the sample orientation. There are, however, very few examples where the measured intensity is directly used, such as for profile/Rietveld refinement, as is common with other powder diffraction data. Although the underlying physics is known, converting the data is time consuming and the appropriate corrections are dispersed across several publications, often not with powder diffraction in mind. This paper presents the angle calculations and correction factors required to calculate meaningful intensities for 2θ scans with a (2 + 3)-type diffractometer and an area detector. Some of the limitations with respect to texture, refraction and instrumental resolution are also discussed, as is the kind of information that one can hope to obtain.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Rujia Li ◽  
Liangcai Cao

AbstractPhase retrieval seeks to reconstruct the phase from the measured intensity, which is an ill-posed problem. A phase retrieval problem can be solved with physical constraints by modulating the investigated complex wavefront. Orbital angular momentum has been recently employed as a type of reliable modulation. The topological charge l is robust during propagation when there is atmospheric turbulence. In this work, topological modulation is used to solve the phase retrieval problem. Topological modulation offers an effective dynamic range of intensity constraints for reconstruction. The maximum intensity value of the spectrum is reduced by a factor of 173 under topological modulation when l is 50. The phase is iteratively reconstructed without a priori knowledge. The stagnation problem during the iteration can be avoided using multiple topological modulations.


2021 ◽  
Vol 118 (14) ◽  
pp. e2021535118
Author(s):  
Joshua Wurman ◽  
Karen Kosiba ◽  
Trevor White ◽  
Paul Robinson

Tornadoes cause damage, injury, and death when intense winds impact structures. Quantifying the strength and extent of such winds is critical to characterizing tornado hazards. Ratings of intensity and size are based nearly entirely on postevent damage surveys [R. Edwards et al., Bull. Am. Meteorol. Soc. 94, 641–653 (2013)]. It has long been suspected that these suffer low bias [C. A. Doswell, D. W. Burgess, Mon. Weather Rev. 116, 495–501 (1988)]. Here, using mapping of low-level tornado winds in 120 tornadoes, we prove that supercell tornadoes are typically much stronger and wider than damage surveys indicate. Our results permit an accurate assessment of the distribution of tornado intensities and sizes and tornado wind hazards, based on actual wind-speed observations, and meaningful comparisons of the distribution of tornado intensities and sizes with theoretical predictions. We analyze data from Doppler On Wheels (DOW) radar measurements of 120 tornadoes at the time of peak measured intensity. In striking contrast to conventional damage-based climatologies, median tornado peak wind speeds are ∼60 m⋅s−1, capable of causing significant, Enhanced Fujita Scale (EF)-2 to -3, damage, and 20% are capable of the most intense EF-4/EF-5 damage. National Weather Service (NWS) EF/wind speed ratings are 1.2 to 1.5 categories (∼20 m⋅s−1) lower than DOW observations for tornadoes documented by both the NWS and DOWs. Median tornado diameter is 250 to 500 m, with 10 to 15% >1 km. Wind engineering tornado-hazard-model predictions and building wind resistance standards may require upward adjustment due to the increased wind-damage risk documented here.


2021 ◽  
Vol 12 (1) ◽  
Author(s):  
Sung-Gyun Yim ◽  
Min-Ji Jung ◽  
Youn-Joong Jeong ◽  
Yeongmin Kim ◽  
Albert Chang-sik Cheong

Abstract Background One of the most critical issues concerning in situ mass spectrometry lies in accounting for elements and molecules that overlap target isotopes of analytical interest in a sample. This study traced the instrumental mass fractionation of Rb and Sr isotopes during laser ablation-multicollector-inductively coupled plasma mass spectrometry (LA-MC-ICPMS) to obtain reliable 87Sr/86Sr ratios for high-Rb/Sr samples. Findings In the LA-MC-ICPMS analysis, Kr interferences were corrected using Ar and He gas blanks measured without ablating material. Contributions from doubly charged Er and Yb ions were corrected using the intensities of half masses and isotopic compositions reported in the literature. After Kr correction, the calculated 166Er2+ intensity of NIST SRM 610 approached the measured intensity at mass 83, and the 173Yb2+/171Yb2+ ratio agreed with the recommended value within error ranges. Kr- and REE2+-stripped peak intensities were further corrected for Rb interference. Use of the Sr mass bias factor for the calculation of measured 87Rb/85Rb yielded 87Sr/86Sr ratios consistent with the recommended and expected values for low-Rb/Sr materials, such as NIST SRM 616, modern shark teeth, and plagioclase collected from Jeju Island, but failed to account for the 87Rb interference from high-Rb/Sr materials including NIST SRM 610 and SRM 612. We calculated in situ mass bias factor of Rb from the known 87Sr/86Sr ratios of the standards and observed a correlation between Rb and Sr mass fractionation, which allowed inference of the Rb bias from the standard run. Reliable 87Sr/86Sr and 85Rb/86Sr ratios were obtained for SRM 610 and SRM 612 using the inferred mass bias factor of Rb calculated by the standard bracketing method. Conclusions This study revealed that Rb and Sr isotopes behave differently during LA-MC-ICPMS and suggests the potential usefulness of the standard bracketing method for measuring the Rb–Sr isotopic compositions of high-Rb/Sr materials.


2020 ◽  
Author(s):  
Mahmoud Al Ahmad ◽  
Farah Mustafa ◽  
Neena Panicker ◽  
Tahir A. Rizvi

AbstractThis study proposes a novel optical method of detecting and reducing SARS-CoV-2 transmission, the virus responsible for the COVID-19 pandemic that is sweeping the world today. SARS-CoV-2 belongs to the β-coronaviruses characterized by the crown-shaped spike protein that protrudes out of the virus particles, giving the virus a “corona” shape; hence the name coronavirus. This virus is similar to the viruses that caused SARS (severe acute respiratory syndrome) and MERS (Middle East respiratory syndrome), the other two coronavirus epidemics that were recently contained within the last ten years. The technique being proposed uses a light source from a smart phone and a mobile spectrophotometer to enable detection of viral proteins in solution or paper as well as protein-protein interactions. The proof-of-concept is shown by detecting soluble preparations of spike protein subunits from SARS-CoV-2, followed by detection of the actual binding potential of the spike protein with its host receptor, the angiotensin-converting enzyme 2 (ACE2). The results are validated by showing that this method can detect antigen-antibody binding using two independent viral protein-antibody pairs. The binding could be detected optically both in solution and on a solid support such as nitrocellulose membrane. Finally, this technique is combined with DC bias to show that introduction of a current into the system can be used to disrupt the antigen-antibody reaction, suggesting that the proposed extended technique can be a potential means of not only detecting the virus, but also reducing virus transmission by disrupting virus-receptor interactions electrically.SignificanceThe measured intensity of light can reveal information about different cellular parameters under study. When light passes through a bio-composition, the intensity is associated with its content. The nuclei size, cell shape and the refractive index variation of cells contributes to light intensity. In this work, an optical label-free real time detection method incorporating the smartphone light source and a portable mini spectrometer for SARS-CoV-2 detection was developed based on the ability of its spike protein to interact with the ACE2 receptor. The light interactions with control and viral protein solutions were capable of providing a quick decision regarding whether the sample under test was positive or negative, thus enabling SARS-CoV-2 detection in a rapid manner.


Atoms ◽  
2020 ◽  
Vol 8 (4) ◽  
pp. 82
Author(s):  
Bhupendra Singh ◽  
Suman Prajapati ◽  
Bhartendu K. Singh ◽  
R. Shanker

The impact energy and angular dependence of L X-rays of a thick polycrystalline tungsten (W; atomic number, Z = 74) target induced by 15–25 keV electrons has been measured at different angles varying from 15° to 75° at intervals of 5° using a Si PIN photodiode detector. The variation of measured relative intensity of Ll, Lα, Lβ and Lγ characteristic lines as a function of incidence angle is found to be anisotropic and the measured variation compares well with the PENELOPE simulation results. The angular variation of intensity ratio of Ll/Lα and Lβ/Lα shows anisotropic distribution, whereas the angular variation of the Lγ/Lα ratio exhibits almost isotropic distribution within the uncertainty of measurements. These measured ratios are found to be in good agreement with Monte Carlo (MC) calculations. The measured intensity ratios of Lβ/Lα and Lγ/Lα at a given incidence angle show a linear dependence with impact energy and exhibit good agreement with simulation results; however, the measured intensity ratio of Ll/Lα shows a non-linear variation with the impact energy and yields poor agreement with theoretical calculations.


Sign in / Sign up

Export Citation Format

Share Document