Impact of rs12917 MGMT Polymorphism on [18F]FDG-PET Response in Pediatric Hodgkin Lymphoma (PHL)

2019 ◽  
Vol 21 (6) ◽  
pp. 1182-1191
Author(s):  
Stefanie Kewitz-Hempel ◽  
Lars Kurch ◽  
Michaela Cepelova ◽  
Ines Volkmer ◽  
Axel Sauerbrey ◽  
...  
2020 ◽  
Vol 7 (1) ◽  
Author(s):  
Amy J. Weisman ◽  
Jihyun Kim ◽  
Inki Lee ◽  
Kathleen M. McCarten ◽  
Sandy Kessel ◽  
...  

Abstract Purpose For pediatric lymphoma, quantitative FDG PET/CT imaging features such as metabolic tumor volume (MTV) are important for prognosis and risk stratification strategies. However, feature extraction is difficult and time-consuming in cases of high disease burden. The purpose of this study was to fully automate the measurement of PET imaging features in PET/CT images of pediatric lymphoma. Methods 18F-FDG PET/CT baseline images of 100 pediatric Hodgkin lymphoma patients were retrospectively analyzed. Two nuclear medicine physicians identified and segmented FDG avid disease using PET thresholding methods. Both PET and CT images were used as inputs to a three-dimensional patch-based, multi-resolution pathway convolutional neural network architecture, DeepMedic. The model was trained to replicate physician segmentations using an ensemble of three networks trained with 5-fold cross-validation. The maximum SUV (SUVmax), MTV, total lesion glycolysis (TLG), surface-area-to-volume ratio (SA/MTV), and a measure of disease spread (Dmaxpatient) were extracted from the model output. Pearson’s correlation coefficient and relative percent differences were calculated between automated and physician-extracted features. Results Median Dice similarity coefficient of patient contours between automated and physician contours was 0.86 (IQR 0.78–0.91). Automated SUVmax values matched exactly the physician determined values in 81/100 cases, with Pearson’s correlation coefficient (R) of 0.95. Automated MTV was strongly correlated with physician MTV (R = 0.88), though it was slightly underestimated with a median (IQR) relative difference of − 4.3% (− 10.0–5.7%). Agreement of TLG was excellent (R = 0.94), with median (IQR) relative difference of − 0.4% (− 5.2–7.0%). Median relative percent differences were 6.8% (R = 0.91; IQR 1.6–4.3%) for SA/MTV, and 4.5% (R = 0.51; IQR − 7.5–40.9%) for Dmaxpatient, which was the most difficult feature to quantify automatically. Conclusions An automated method using an ensemble of multi-resolution pathway 3D CNNs was able to quantify PET imaging features of lymphoma on baseline FDG PET/CT images with excellent agreement to reference physician PET segmentation. Automated methods with faster throughput for PET quantitation, such as MTV and TLG, show promise in more accessible clinical and research applications.


2019 ◽  
Vol 212 (2) ◽  
pp. 456-460 ◽  
Author(s):  
Laura K. Sedig ◽  
Jason J. Bailey ◽  
Ka Kit Wong ◽  
Richard K. J. Brown ◽  
Mark S. Kaminski ◽  
...  

2020 ◽  
Vol 45 (8) ◽  
pp. 652-653 ◽  
Author(s):  
Xavier L.E. Boulvard Chollet ◽  
Leonardo G. Romero Robles ◽  
Puy Garrastachu ◽  
Antonio Cabrera Villegas ◽  
M. Clara Albornoz Almada ◽  
...  
Keyword(s):  
Fdg Pet ◽  
Pet Ct ◽  
18F Fdg ◽  

2010 ◽  
Vol 51 (9) ◽  
pp. 1337-1343 ◽  
Author(s):  
J. J. Cerci ◽  
L. F. Pracchia ◽  
C. C. G. Linardi ◽  
F. A. Pitella ◽  
D. Delbeke ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document