automatic segmentation
Recently Published Documents


TOTAL DOCUMENTS

3146
(FIVE YEARS 1037)

H-INDEX

73
(FIVE YEARS 11)

2022 ◽  
Vol 3 (2) ◽  
pp. 1-15
Author(s):  
Junqian Zhang ◽  
Yingming Sun ◽  
Hongen Liao ◽  
Jian Zhu ◽  
Yuan Zhang

Radiation-induced xerostomia, as a major problem in radiation treatment of the head and neck cancer, is mainly due to the overdose irradiation injury to the parotid glands. Helical Tomotherapy-based megavoltage computed tomography (MVCT) imaging during the Tomotherapy treatment can be applied to monitor the successive variations in the parotid glands. While manual segmentation is time consuming, laborious, and subjective, automatic segmentation is quite challenging due to the complicated anatomical environment of head and neck as well as noises in MVCT images. In this article, we propose a localization-refinement scheme to segment the parotid gland in MVCT. After data pre-processing we use mask region convolutional neural network (Mask R-CNN) in the localization stage after data pre-processing, and design a modified U-Net in the following fine segmentation stage. To the best of our knowledge, this study is a pioneering work of deep learning on MVCT segmentation. Comprehensive experiments based on different data distribution of head and neck MVCTs and different segmentation models have demonstrated the superiority of our approach in terms of accuracy, effectiveness, flexibility, and practicability. Our method can be adopted as a powerful tool for radiation-induced injury studies, where accurate organ segmentation is crucial.


2022 ◽  
Vol 22 (1) ◽  
Author(s):  
Jens P.E. Schouten ◽  
Samantha Noteboom ◽  
Roland M. Martens ◽  
Steven W. Mes ◽  
C. René Leemans ◽  
...  

Abstract Background  Accurate segmentation of head and neck squamous cell cancer (HNSCC) is important for radiotherapy treatment planning. Manual segmentation of these tumors is time-consuming and vulnerable to inconsistencies between experts, especially in the complex head and neck region. The aim of this study is to introduce and evaluate an automatic segmentation pipeline for HNSCC using a multi-view CNN (MV-CNN). Methods The dataset included 220 patients with primary HNSCC and availability of T1-weighted, STIR and optionally contrast-enhanced T1-weighted MR images together with a manual reference segmentation of the primary tumor by an expert. A T1-weighted standard space of the head and neck region was created to register all MRI sequences to. An MV-CNN was trained with these three MRI sequences and evaluated in terms of volumetric and spatial performance in a cross-validation by measuring intra-class correlation (ICC) and dice similarity score (DSC), respectively. Results The average manual segmented primary tumor volume was 11.8±6.70 cm3 with a median [IQR] of 13.9 [3.22-15.9] cm3. The tumor volume measured by MV-CNN was 22.8±21.1 cm3 with a median [IQR] of 16.0 [8.24-31.1] cm3. Compared to the manual segmentations, the MV-CNN scored an average ICC of 0.64±0.06 and a DSC of 0.49±0.19. Improved segmentation performance was observed with increasing primary tumor volume: the smallest tumor volume group (<3 cm3) scored a DSC of 0.26±0.16 and the largest group (>15 cm3) a DSC of 0.63±0.11 (p<0.001). The automated segmentation tended to overestimate compared to the manual reference, both around the actual primary tumor and in false positively classified healthy structures and pathologically enlarged lymph nodes. Conclusion An automatic segmentation pipeline was evaluated for primary HNSCC on MRI. The MV-CNN produced reasonable segmentation results, especially on large tumors, but overestimation decreased overall performance. In further research, the focus should be on decreasing false positives and make it valuable in treatment planning.


2022 ◽  
Vol 22 (1) ◽  
Author(s):  
Umut Karaca ◽  
Murat Kucukevcilioglu ◽  
Ali Hakan Durukan ◽  
Dorukcan Akincioglu

Abstract Background The study aims to evaluate peripapillary retinal nerve fiber layer thickness (RNFL-T), central macular thickness (MT), choroidal thickness (CT), and thickness of each retinal layer after automatic segmentation in patients who underwent retinal detachment (RD) repair with longstanding silicone oil tamponade. Methods We enrolled 33 patients who underwent complicated primary rhegmatogenous RD surgery and followed up with a long-term silicone tamponade were included in this retrospective comparative (case–control) study. RNFL-T, CT, and thickness of each retinal layer after automatic segmentation analysis were measured after the longstanding silicone removal surgery. Results The mean silicone oil removal time was 15.1 ± 15.2 (7–70) months. The overall average thickness of the RNFL was 90.7 ± 13.6 μm in the operated eyes and 118.3 ± 35.6 μm in the sound eyes, with a statistically significant difference. The overall average central MT was 186.3 ± 57.7 μm and was significantly lower in the operated eyes than in the sound eyes. Inner retinal layers of the study group showed a significant thinning in the nerve fiber layer, ganglion cell layer, inner plexiform layer, and inner nuclear layer as compared to that of the sound eyes. The subfoveal CT was 213.7 ± 86.6 μm in the study eyes and 217.7 ± 115.5 μm in the control eyes. There was no significant difference between the study eyes and controls. Conclusion The effects of silicone oil on the retina remain uncertain; however, morphological results in our study have shown direct or indirect silicone oil–induced toxicity, especially in the inner retinal layers.


2022 ◽  
Vol 22 (1) ◽  
Author(s):  
Xi Guan ◽  
Guang Yang ◽  
Jianming Ye ◽  
Weiji Yang ◽  
Xiaomei Xu ◽  
...  

Abstract Background Glioma is the most common brain malignant tumor, with a high morbidity rate and a mortality rate of more than three percent, which seriously endangers human health. The main method of acquiring brain tumors in the clinic is MRI. Segmentation of brain tumor regions from multi-modal MRI scan images is helpful for treatment inspection, post-diagnosis monitoring, and effect evaluation of patients. However, the common operation in clinical brain tumor segmentation is still manual segmentation, lead to its time-consuming and large performance difference between different operators, a consistent and accurate automatic segmentation method is urgently needed. With the continuous development of deep learning, researchers have designed many automatic segmentation algorithms; however, there are still some problems: (1) The research of segmentation algorithm mostly stays on the 2D plane, this will reduce the accuracy of 3D image feature extraction to a certain extent. (2) MRI images have gray-scale offset fields that make it difficult to divide the contours accurately. Methods To meet the above challenges, we propose an automatic brain tumor MRI data segmentation framework which is called AGSE-VNet. In our study, the Squeeze and Excite (SE) module is added to each encoder, the Attention Guide Filter (AG) module is added to each decoder, using the channel relationship to automatically enhance the useful information in the channel to suppress the useless information, and use the attention mechanism to guide the edge information and remove the influence of irrelevant information such as noise. Results We used the BraTS2020 challenge online verification tool to evaluate our approach. The focus of verification is that the Dice scores of the whole tumor, tumor core and enhanced tumor are 0.68, 0.85 and 0.70, respectively. Conclusion Although MRI images have different intensities, AGSE-VNet is not affected by the size of the tumor, and can more accurately extract the features of the three regions, it has achieved impressive results and made outstanding contributions to the clinical diagnosis and treatment of brain tumor patients.


2022 ◽  
Vol 3 ◽  
Author(s):  
Niranjan J. Sathianathen ◽  
Nicholas Heller ◽  
Resha Tejpaul ◽  
Bethany Stai ◽  
Arveen Kalapara ◽  
...  

Purpose: Clinicians rely on imaging features to calculate complexity of renal masses based on validated scoring systems. These scoring methods are labor-intensive and are subjected to interobserver variability. Artificial intelligence has been increasingly utilized by the medical community to solve such issues. However, developing reliable algorithms is usually time-consuming and costly. We created an international community-driven competition (KiTS19) to develop and identify the best system for automatic segmentation of kidneys and kidney tumors in contrast CT and report the results.Methods: A training and test set of CT scans that was manually annotated by trained individuals were generated from consecutive patients undergoing renal surgery for whom demographic, clinical and outcome data were available. The KiTS19 Challenge was a machine learning competition hosted on grand-challenge.org in conjunction with an international conference. Teams were given 3 months to develop their algorithm using a full-annotated training set of images and an unannotated test set was released for 2 weeks from which average Sørensen-Dice coefficient between kidney and tumor regions were calculated across all 90 test cases.Results: There were 100 valid submissions that were based on deep neural networks but there were differences in pre-processing strategies, architectural details, and training procedures. The winning team scored a 0.974 kidney Dice and a 0.851 tumor Dice resulting in 0.912 composite score. Automatic segmentation of the kidney by the participating teams performed comparably to expert manual segmentation but was less reliable when segmenting the tumor.Conclusion: Rapid advancement in automated semantic segmentation of kidney lesions is possible with relatively high accuracy when the data is released publicly, and participation is incentivized. We hope that our findings will encourage further research that would enable the potential of adopting AI into the medical field.


Author(s):  
Julien Issa ◽  
Raphael Olszewski ◽  
Marta Dyszkiewicz-Konwińska

This systematic review aims to identify the available semi-automatic and fully automatic algorithms for inferior alveolar canal localization as well as to present their diagnostic accuracy. Articles related to inferior alveolar nerve/canal localization using methods based on artificial intelligence (semi-automated and fully automated) were collected electronically from five different databases (PubMed, Medline, Web of Science, Cochrane, and Scopus). Two independent reviewers screened the titles and abstracts of the collected data, stored in EndnoteX7, against the inclusion criteria. Afterward, the included articles have been critically appraised to assess the quality of the studies using the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) tool. Seven studies were included following the deduplication and screening against exclusion criteria of the 990 initially collected articles. In total, 1288 human cone-beam computed tomography (CBCT) scans were investigated for inferior alveolar canal localization using different algorithms and compared to the results obtained from manual tracing executed by experts in the field. The reported values for diagnostic accuracy of the used algorithms were extracted. A wide range of testing measures was implemented in the analyzed studies, while some of the expected indexes were still missing in the results. Future studies should consider the new artificial intelligence guidelines to ensure proper methodology, reporting, results, and validation.