Treatment plan complexity metrics for predicting IMRT pre-treatment quality assurance results

2014 ◽  
Vol 37 (3) ◽  
pp. 475-482 ◽  
Author(s):  
S. B. Crowe ◽  
T. Kairn ◽  
J. Kenny ◽  
R. T. Knight ◽  
B. Hill ◽  
...  
2017 ◽  
Vol 44 ◽  
pp. 35-36
Author(s):  
F. Ralite ◽  
T. Marsac ◽  
A. Cugny ◽  
J. Caron ◽  
P. Sargos ◽  
...  

2021 ◽  
Author(s):  
Marco Fusella ◽  
Samuele Cavinato ◽  
Alessandra Germani ◽  
Marta Paiusco ◽  
Nicola Pivato ◽  
...  

Abstract Purpose: This study presents patient-specific quality assurance (QA) results from the first 395 clinical cases for the new helical TomoTherapy® platform (Radixact) coupled with dedicated Precision TPS.Methods: The passing rate of the Gamma Index (GP%) of 395 helical QA of patient-specific Tomotherapy, acquired with ArcCHECK, is presented, analysed and correlated to various parameters of the plan. Following TG-218 recommendations, the clinic specific action limit (ALcs) and tolerance limit (TLcs) were calculated for our clinic and monitored during the analysed period.Results: the mean values ​​(± 1 standard deviation) of GP% (3% / 2mm) (both global and local normalization) are: 97.6% and 90.9%, respectively. The proposed ALcs and TLcs, after a period of two years’ process monitoring are 89.4% and 91.1% respectively.Conclusions: The phantom measurements closely match the planned dose distributions, demonstrating that the calculation accuracy of the new Precision TPS and the delivery accuracy of the Radixact unit are adequate, with respect to international guidelines and reports. Furthermore, a first correlation with the planning parameters was made. Action and tolerance limits have been set for the new Radixact Linac.


Author(s):  
Ernest Osei ◽  
Sarah Graves ◽  
Johnson Darko

Abstract Background: The complexity associated with the treatment planning and delivery of stereotactic radiosurgery (SRS) or stereotactic radiotherapy (SRT) volumetric modulated arc therapy (VMAT) plans which employs continuous dynamic modulation of dose rate, field aperture and gantry speed necessitates diligent pre-treatment patient-specific quality assurance (QA). Numerous techniques for pre-treatment VMAT treatment plans QA are currently available with the aid of several different devices including the electronic portal imager (EPID). Although several studies have provided recommendations for gamma criteria for VMAT pre-treatment QA, there are no specifics for SRS/SRT VMAT QA. Thus, we conducted a study to evaluate intracranial SRS/SRT VMAT QA to determine clinical action levels for gamma criteria based on the institutional estimated means and standard deviations. Materials and methods: We conducted a retrospective analysis of 118 EPID patient-specific pre-treatment QA dosimetric measurements of 47 brain SRS/SRT VMAT treatment plans using the integrated Varian solution (RapidArcTM planning, EPID and Portal dosimetry system) for planning, delivery and EPID QA analysis. We evaluated the maximum gamma (γmax), average gamma (γave) and percentage gamma passing rate (%GP) for different distance-to-agreement/dose difference (DTA/DD) criteria and low-dose thresholds. Results: The gamma index analysis shows that for patient-specific SRS/SRT VMAT QA with the portal dosimetry, the mean %GP is ≥98% for 2–3 mm/1–3% and Field+0%, +5% and +10% low-dose thresholds. When applying stricter spatial criteria of 1 mm, the mean %GP is >90% for DD of 2–3% and ≥88% for DD of 1%. The mean γmax ranges: 1·32 ± 1·33–2·63 ± 2·35 for 3 mm/1–3%, 1·57 ± 1·36–2·87 ± 2·29 for 2 mm/1–3% and 2·36 ± 1·83–3·58 ± 2·23 for 1 mm/1–3%. Similarly the mean γave ranges: 0·16 ± 0·06–0·19 ± 0·07 for 3 mm/1–3%, 0·21 ± 0·08–0·27 ± 0·10 for 2 mm/1–3% and 0·34 ± 0·14–0·49 ± 0·17 for 1 mm/1–3%. The mean γmax and mean γave increase with increased DTA and increased DD for all low-dose thresholds. Conclusions: The establishment of gamma criteria local action levels for SRS/SRT VMAT pre-treatment QA based on institutional resources is imperative as a useful tool for standardising the evaluation of EPID-based patient-specific SRS/SRT VMAT QA. Our data suggest that for intracranial SRS/SRT VMAT QA measured with the EPID, a stricter gamma criterion of 1 mm/2% or 1 mm/3% with ≥90% %GP could be used while still maintaining an in-control QA process with no extra burden on resources and time constraints.


2015 ◽  
Vol 115 ◽  
pp. S751-S752
Author(s):  
A. Bruschi ◽  
S. Russo ◽  
M. Esposito ◽  
S. Pini ◽  
A. Ghirelli ◽  
...  

2015 ◽  
Vol 115 ◽  
pp. S762-S763
Author(s):  
L. Reversi ◽  
C. Talamonti ◽  
E. Vanzi ◽  
G. Giani ◽  
M. Casati ◽  
...  

2016 ◽  
Vol 118 (3) ◽  
pp. 574-576 ◽  
Author(s):  
Sara Bresciani ◽  
Anna Miranti ◽  
Amalia Di Dia ◽  
Angelo Maggio ◽  
Christian Bracco ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document