A simple method for percutaneous cannulation of the internal jugular vein

1978 ◽  
Vol 135 (5) ◽  
pp. 722-723 ◽  
Author(s):  
James C. Stevens ◽  
Harold F. Hamit
2007 ◽  
Vol 61 (suppl_5) ◽  
pp. ONSE398-ONSE398
Author(s):  
Licia Di Muro ◽  
Roberto Pallini ◽  
Domenico Pietrini ◽  
Christian Colizzi ◽  
Luca Denaro

Abstract Objective: We describe a minimally invasive echo-guided placement of the cardiac tube in a ventriculoatrial shunt in a young pregnant woman, in order to avoid any radiological procedure. Methods: We used a central venous catheter placement kit for percutaneous echo-guided right internal jugular vein puncture located by a 7.5 mHz microlinear probe. Through the catheter, the distal portion of the shunt device was positioned into the internal jugular vein to the right atrium using ultrasound control by a 2.5 to 3.5 mHz probe in a four-chamber transthoracic view. Results: Sonographic guidance in percutaneous placement of a vertebral artery shunt is a safe and fast minimally invasive technique that improves success rates and decreases complications such as incidental puncture of the carotid artery and pneumothorax. The use of a two-dimensional echocardiographic apparatus in a four-chamber transthoracic view is an accurate and simple method to verify the position of the distal tip of the shunt in the mid-right atrium with no risks for the patient. Conclusion: The use of these two techniques allows a minimally invasive, safe, accurate, and complete x-ray-free procedure.


1993 ◽  
Vol 78 (4) ◽  
pp. 792-792 ◽  
Author(s):  
Eijl Oshima ◽  
Koichi Ishizu ◽  
Nobukata Urabe

2011 ◽  
Vol 26 (6) ◽  
pp. 392-396 ◽  
Author(s):  
William T. McGee ◽  
Patrick T. Mailloux ◽  
Richard T. Martin

Introduction. To develop a simple method for safely placing central venous catheters (CVCs) outside the heart from the subclavian or internal jugular vein in compliance with Food and Drug Administration (FDA) and manufacturer guidelines. Methods. Patients requiring CVCs were enrolled into this prospective trial. Central venous catheters were inserted into the subclavian or internal jugular vein from either the right or left side to a depth of 15 cm. Chest radiographs were obtained immediately after insertion of the catheter to check tip placement and to evaluate for mechanical complications. Results. Operators successfully placed 201 of 210 (96%) CVCs outside the heart. Six of these required repositioning. Nine catheter tips were located in an intracardiac position. No cases of pneumothorax, hemothorax, or pericardial tamponade occurred. One case of delayed hydrothorax due to superior vena cava injury occurred. Conclusions. Using a 15-cm insertion depth via the internal jugular or subclavian vein results in safe catheter tip location in the majority of procedures consistent with FDA and manufacturer guidelines.


Thorax ◽  
1972 ◽  
Vol 27 (4) ◽  
pp. 496-499 ◽  
Author(s):  
J. D. Wisheart ◽  
M. A. Hassan ◽  
J. W. Jackson

Sign in / Sign up

Export Citation Format

Share Document