internal jugular vein
Recently Published Documents


TOTAL DOCUMENTS

2302
(FIVE YEARS 384)

H-INDEX

52
(FIVE YEARS 4)

Cureus ◽  
2022 ◽  
Author(s):  
Youssef Aladham ◽  
Sheikh Muktadir Bin Momin ◽  
Omar Ahmed ◽  
Samuel Jackson

Author(s):  
Zhenkang Qiu ◽  
Wenliang Zhu ◽  
Huzheng Yan ◽  
Guobao Wang ◽  
Mengxuan Zuo ◽  
...  

Abstract Purpose To compare the safety and efficacy of left versus right internal jugular vein access for portal vein puncture during transjugular intrahepatic portosystemic shunt (TIPS) creation in patients with a small liver and short vertical puncture distance. Materials and Methods The vertical distance from the hepatic vein orifice to the puncture point of the portal vein was measured by CT and DSA. A distance ≤ 30 mm is defined as a short vertical puncture distance. After 1:1 propensity score matching (PSM), 29 patients of left internal jugular vein-TIPS (LIJ-TIPS) and 29 patients of right internal jugular vein-TIPS (RIJ-TIPS) were included. The number of needle punctures, fluoroscopy time, and radiation dose during the puncture process were statistically analyzed. Results There was no significant difference in the average vertical puncture distances on CT or DSA between LIJ-TIPS and RIJ-TIPS (19.10 ± 0.60 mm vs. 19.30 ± 0.60 mm, P = 0.840; 22.02 ± 0.69 mm vs. 22.23 ± 0.64 mm, P = 0.822, respectively). The average number of needle punctures, fluoroscopy time, and radiation dose in LIJ-TIPS were significantly lower than those in RIJ-TIPS (2.07 ± 0.20 vs. 4.10 ± 0.24, P < 0.001; 78.45 ± 12.80 s vs. 201.16 ± 23.71 s, P < 0.001; 31.55 ± 7.04 mGy vs. 136.69 ± 16.38 mGy, P < 0.001, respectively). Within three punctures, the technical success rate in LIJ-TIPS was significantly higher than that in RIJ-TIPS (86.2 vs. 27.6%, P < 0.001). The incidence of hemoperitoneum in LIJ-TIPS was significantly lower than that in RIJ-TIPS (0% vs. 13.8%, P = 0.038). Conclusion The left internal jugular vein could be used as primary access for TIPS creation in patients with a small liver and short vertical puncture distance.


2021 ◽  
pp. 1-3
Author(s):  
Taylor J. Kavanaugh ◽  
Chad Wiesenauer ◽  
Richard Miyamoto ◽  
Constantine Mavroudis

Abstract Venous aneurysms are an atypical presentation of neck masses in the paediatric population. The evaluation and surgical removal of internal jugular vein phlebectasia and a lipoma coexisting are described in this report. Internal jugular vein phlebectasia is theorised as a congenital defect and is becoming more common with advancing imaging technologies. Both phlebectasia and lipomas are considered benign conditions, but clinicians must be aware of tumours producing mass effect.


2021 ◽  
Vol 69 (1) ◽  
Author(s):  
Mohamed Mahmoud Shalaby ◽  
Rami Mohammed Salama ◽  
Mohammed Awad Mansour

Abstract Background Central venous line insertion in neonates is an important and lifesaving procedure. It can carry significant risks and complications, including death, at the time of insertion or later. We aimed to retrospectively assess the modified Seldinger technique for open placement of a central venous catheter in neonates, regarding its safety, feasibility, operative time, and preservation of the patency of the internal jugular vein. This study was conducted on 120 neonates from March 2018 to March 2020. We closely monitored the pulse for the detection of arrhythmia or bradycardia, which might be caused during the insertion of the guide wire or the tip of the catheter. Post-operative X-ray was done immediately after the end of the procedure for all cases, to determine the site of the central venous catheter and to detect the presence of pneumothorax. Results Arrhythmia was observed in 9 cases (7.5%), and blood oozing in 5 cases (4.1%). There were 3 cases of pneumothorax (2.5%), 2 cases of neck hematoma in two cases (1.6%), 6 cases of internal jugular vein thrombosis (5%), and dislodging of the catheter in 3 cases (2.5%). There were no cases of arterial puncture, failure of cannulation, or haemothorax in our study. Conclusions The modified Seldinger technique insertion for open central venous line in neonates is a safe, accessible, and feasible method, especially in centers that lack the experience of ultrasound-guided insertion in neonates.


2021 ◽  
Vol 11 (3) ◽  
pp. 141-144
Author(s):  
Eun Ji Lee ◽  
Hojong Park ◽  
Kyu Hyouck Kyoung ◽  
Sang Jun Park

A case of a 30-year-old man who was admitted following a penetrating neck injury is presented. A clinical examination and operative findings identified semi-comatose mentality, neck muscle laceration, and transection of the left common carotid and vertebral arteries and the internal jugular vein. During the operation, the carotid arteries were repaired by interposition grafting, and the internal jugular vein was ligated. The vertebral artery was managed by interventional embolization. Although the patient had some neurological deficit, he was discharged on postoperative Day 52. This surgical case prompted a discussion regarding neurological outcomes, and surgical and endovascular treatment following vascular neck injury.


Author(s):  
Harm J. Scholten ◽  
Michael I. Meesters ◽  
Leon J. Montenij ◽  
Erik H. M. Korsten ◽  
R. Arthur Bouwman ◽  
...  

Author(s):  
Ahmed Abd Alrahman Baz ◽  
Amro Abdulrahim Ibrahim ◽  
Hussein Saeed El-Fishawy ◽  
Abo El-Magd Mohamed Al-Bohy

Abstract Background Assessment of the central venous pressure (CVP) is an essential hemodynamic parameter for monitoring the dialyzing patients. Our objective of the present study is to investigate the accuracy of CVP measurement by internal jugular vein US in comparison to the direct measurement by the central venous catheters for hemodialysis patients. We included 106 patients; where their CVP was assessed in two different non invasive US methods (CVPni) separately and in combination and the obtained measurements were correlated to the invasive measurements (CVPi) by catheters. Results By method 1, there is a highly significant positive correlation between CVPni and CVPi (ρ < 0.001) and a Pearson correlation coefficient (r = 0.913 n = 93), and by method 2, there is also a highly significant positive correlation between the CVPni and CVPi in both groups (r = 0.832, 95%, n = 106, p < 0.001), 1.935 was the cut-off point for prediction of CVP ≥ 10cmH20. For differentiation between patients with CVP < 10cmH20 and ≥ 10cmH20, the accuracy measures (sensitivity, specificity, PPV, NPV, and overall accuracy) were 100%, 79.31%, 74.47%, 100%, and 87.10% by method 1, and were 91.11%, 85.48%, 82.00%, 92.98%, and 87.85% by method 2, while the combination of both methods had gained 88.57%, 89.66%, 83.78%, 92.86%, and 89.25%, respectively. Conclusion The US offered a reliable and non-invasive tool for monitoring CVP. The present study has a novelty of combining more than one US method and this had reported higher accuracy measures and outperformed the use of a single method.


2021 ◽  
Vol 233 (5) ◽  
pp. e234
Author(s):  
Alejandro Quiroga-Garza ◽  
Yenitzeh AK. Hernández-Garate ◽  
Raul A. de Luna Vega ◽  
Bernardo Alfonso Fernandez-Rodarte ◽  
Ricardo Pinales-Razo ◽  
...  

2021 ◽  
Vol 233 (5) ◽  
pp. e246
Author(s):  
Alejandro Quiroga-Garza ◽  
Mariana Garcia-Leal ◽  
Adrian M. Verdines-Perez ◽  
Humberto de Leon-Gutierrez ◽  
Bernardo Alfonso Fernandez-Rodarte ◽  
...  

Author(s):  
Alireza Zeraatchi ◽  
Taraneh Naghibi ◽  
Hamid Kafili ◽  
Somayeh Abdollahi Sabet

Background: Hemodynamic monitoring its early stabilization is very important in critically ill patients. Evaluating the Internal jugular vein diameter during respiratory cycles by the means of Point-of care ultrasound provides an important, easily available and precise index for monitoring hemodynamic status; a new method which is called Internal Jugular Vein Collapsibility Index (IJV-CI). Any events that alters intrathoracic volumes and pressures may affect this index. In this study we investigate the effects of various levels of positive end-expiratory pressure on this index. Methods: Thirty mechanically ventilated patients were studied. We used three different PEEP levels (0, 5 and 10 cmH2o) and point-of-care ultrasound evaluation of IJV (Internal Jugular Vein) diameter to determine the IJV-CI. The analysis were performed using SPSS V.25.0. Results: Patients were included men (76.6%) and women (33.3%). The mean age of patients was 39.65±3.4 for men and 42.71± 9.34 for women. The IJV-CI were 20.71±11.77 and 24.25±11.46 in PEEP=0 and PEEP=10 cmH20 groups respectively. In 5cmH20-PEEP group median and interquartile range were 16.45(14.8). The IJV-CI in three different PEEP levels were not statistically significantly different. Conclusion: According to the finding of this study, we found no evidence of an optimal PEEP level to measure The IJV-CI.


Sign in / Sign up

Export Citation Format

Share Document