Life-threatening hemothorax due to azygos vein rupture after chest compression during cardiopulmonary resuscitation

2014 ◽  
Vol 32 (11) ◽  
pp. 1437.e1-1437.e2 ◽  
Author(s):  
Euiseok Yang ◽  
WonJoon Jeong ◽  
JunWan Lee ◽  
SeungWhan Kim
Diagnostics ◽  
2021 ◽  
Vol 11 (6) ◽  
pp. 1122
Author(s):  
Jessica Graef ◽  
Bernd A. Leidel ◽  
Keno K. Bressem ◽  
Janis L. Vahldiek ◽  
Bernd Hamm ◽  
...  

Computed tomography (CT) represents the current standard for imaging of patients with acute life-threatening diseases. As some patients present with circulatory arrest, they require cardiopulmonary resuscitation. Automated chest compression devices are used to continue resuscitation during CT examinations, but tend to cause motion artifacts degrading diagnostic evaluation of the chest. The aim was to investigate and evaluate a CT protocol for motion-free imaging of thoracic structures during ongoing mechanical resuscitation. The standard CT trauma protocol and a CT protocol with ECG triggering using a simulated ECG were applied in an experimental setup to examine a compressible thorax phantom during resuscitation with two different compression devices. Twenty-eight phantom examinations were performed, 14 with AutoPulse® and 14 with corpuls cpr®. With each device, seven CT examinations were carried out with ECG triggering and seven without. Image quality improved significantly applying the ECG-triggered protocol (p < 0.001), which allowed almost artifact-free chest evaluation. With the investigated protocol, radiation exposure was 5.09% higher (15.51 mSv vs. 14.76 mSv), and average reconstruction time of CT scans increased from 45 to 76 s. Image acquisition using the proposed CT protocol prevents thoracic motion artifacts and facilitates diagnosis of acute life-threatening conditions during continuous automated chest compression.


Author(s):  
Dongjun Yang ◽  
Wongyu Lee ◽  
Jehyeok Oh

Although the use of audio feedback with devices such as metronomes during cardiopulmonary resuscitation (CPR) is a simple method for improving CPR quality, its effect on the quality of pediatric CPR has not been adequately evaluated. In this study, 64 healthcare providers performed CPR (with one- and two-handed chest compression (OHCC and THCC, respectively)) on a pediatric resuscitation manikin (Resusci Junior QCPR), with and without audio feedback using a metronome (110 beats/min). CPR was performed on the floor, with a compression-to-ventilation ratio of 30:2. For both OHCC and THCC, the rate of achievement of an adequate compression rate during CPR was significantly higher when performed with metronome feedback than that without metronome feedback (CPR with vs. without feedback: 100.0% (99.0, 100.0) vs. 94.0% (69.0, 99.0), p < 0.001, for OHCC, and 100.0% (98.5, 100.0) vs. 91.0% (34.5, 98.5), p < 0.001, for THCC). However, the rate of achievement of adequate compression depth during the CPR performed was significantly higher without metronome feedback than that with metronome feedback (CPR with vs. without feedback: 95.0% (23.5, 99.5) vs. 98.5% (77.5, 100.0), p = 0.004, for OHCC, and 99.0% (95.5, 100.0) vs. 100.0% (99.0, 100.0), p = 0.003, for THCC). Although metronome feedback during pediatric CPR could increase the rate of achievement of adequate compression rates, it could cause decreased compression depth.


2012 ◽  
Vol 29 ◽  
pp. 190 ◽  
Author(s):  
P. Schober ◽  
R. Krage ◽  
V. Lagerburg ◽  
D. van Groeningen ◽  
S. A. Loer ◽  
...  

2000 ◽  
Vol 342 (21) ◽  
pp. 1546-1553 ◽  
Author(s):  
Alfred Hallstrom ◽  
Leonard Cobb ◽  
Elise Johnson ◽  
Michael Copass

2013 ◽  
Vol 31 (6) ◽  
pp. 910-915 ◽  
Author(s):  
Jesús Ruiz ◽  
Unai Ayala ◽  
Sofía Ruiz de Gauna ◽  
Unai Irusta ◽  
Digna González-Otero ◽  
...  

2021 ◽  
Vol 13 (11) ◽  
pp. 448-455
Author(s):  
Tiffany Wai Shan Lau ◽  
Anthony Robert Lim ◽  
Kyra Anne Len ◽  
Loren Gene Yamamoto

Background: Chest compression efficacy determines blood flow in cardiopulmonary resuscitation (CPR) and relies on body mechanics, so resuscitator weight matters. Individuals of insufficient weight are incapable of generating a sufficient downward chest compression force using traditional methods. Aims: This study investigated how a resuscitator's weight affects chest compression efficacy, determined the minimum weight required to perform chest compressions and, for children and adults below this minimum weight, examine alternate means to perform chest compressions. Methods: Volunteers aged 8 years and above were enrolled to perform video-recorded, music-facilitated, compression-only CPR on an audible click-confirming manikin for 2 minutes, following brief training. Subjects who failed this proceeded to alternate modalities: chest compressions by jumping on the lower sternum; and squat-bouncing (bouncing the buttocks on the chest). These methods were assessed via video review. Findings: There were 57 subjects. The 30 subjects above 40kg were all able to complete nearly 200 compressions in 2 minutes. Success rates declined in those who weighed less than 40kg. Below 30 kg, only one subject (29.9 kg weight) out of 14 could achieve 200 effective compressions. Nearly all of the 23 subjects who could not perform conventional chest compressions were able to achieve effective chest compressions using alternate methods. Conclusion: A weight below 40kg resulted in a declining ability to perform standard chest compressions effectively. For small resuscitators, the jumping and squat-bouncing methods resulted in sufficient compressions most of the time; however, chest recoil and injuries are concerns.


Sign in / Sign up

Export Citation Format

Share Document