A Biomechanical Comparison of 2 Techniques of Footprint Reconstruction for Rotator Cuff Repair: The SwiveLock-FiberChain Construct Versus Standard Double-Row Repair

2009 ◽  
Vol 25 (3) ◽  
pp. 274-281 ◽  
Author(s):  
Stephen S. Burkhart ◽  
Christopher R. Adams ◽  
Sarah S. Burkhart ◽  
John D. Schoolfield
2005 ◽  
Vol 33 (12) ◽  
pp. 1861-1868 ◽  
Author(s):  
Augustus D. Mazzocca ◽  
Peter J. Millett ◽  
Carlos A. Guanche ◽  
Stephen A. Santangelo ◽  
Robert A. Arciero

Background Recurrent defects after open and arthroscopic rotator cuff repair are common. Double-row repair techniques may improve initial fixation and quality of rotator cuff repair. Purpose To evaluate the load to failure, cyclic displacement, and anatomical footprint of 4 arthroscopic rotator cuff repair techniques. Hypothesis Double-row suture anchor repair would have superior structural properties and would create a larger footprint compared to single-row repair. Study Design Controlled laboratory study. Methods Twenty fresh-frozen cadaveric shoulders were randomly assigned to 4 arthroscopic repair techniques. The repair was performed as either a single-row technique or 1 of 3 double-row techniques: diamond, mattress double anchor, or modified mattress double anchor. Angle of loading, anchor type, bone mineral density, anchor distribution, angle of anchor insertion, arthroscopic technique, and suture type and size were all controlled. Footprint length and width were quantified before and after repair. Displacement with cyclic loading and load to failure were determined. Results There were no differences in load to failure and displacement with cyclic loading between the single-row repair and each double-row repair. All repair groups demonstrated load to failure greater than 250 N. A significantly greater supraspinatus footprint width was seen with double-row techniques compared to single-row repair. Conclusions The single-row repair technique was similar to the double-row techniques in load to failure, cyclic displacement, and gap formation. The double-row anchor repairs consistently restored a larger footprint than did the single-row method. Clinical Relevance The arthroscopic techniques studied have strong structural properties that approached the reported performance of open repair techniques. Double-row techniques provide a larger footprint width; although not addressed by this study, such a factor may improve the biological quality of repair.


2007 ◽  
Vol 16 (4) ◽  
pp. 461-468 ◽  
Author(s):  
Maxwell C. Park ◽  
Neal S. ElAttrache ◽  
James E. Tibone ◽  
Christopher S. Ahmad ◽  
Bong-Jae Jun ◽  
...  

2007 ◽  
Vol 16 (4) ◽  
pp. 469-476 ◽  
Author(s):  
Maxwell C. Park ◽  
James E. Tibone ◽  
Neal S. ElAttrache ◽  
Christopher S. Ahmad ◽  
Bong-Jae Jun ◽  
...  

Author(s):  
Theodore F. Schlegel ◽  
Karimdad Amir Otarodifard ◽  
Richard J. Hawkins ◽  
Thomas Vangsness ◽  
Christopher Bui ◽  
...  

A transosseous-equivalent rotator cuff repair has shown improved biomechanical characteristics compared to other more cumbersome arthroscopic double row repairs. However, the transosseous equivalent repair, which requires knot tying, still can be challenging when tensioning the repair construct. We hypothesized that a knotless dual row loop repair has similar biomechanical characteristics to the transosseous-equivalent rotator cuff repair. Therefore, the objective of this study was to quantify and compare the biomechanical characteristics of a knotless double row repair and transosseous equivalent rotator cuff repair using matched pair shoulders.