scholarly journals Three Year Patency and Recurrence Rates of Revision Using Distal Inflow with a Venous Interposition Graft for High Flow Brachial Artery Based Arteriovenous Fistula

2018 ◽  
Vol 55 (6) ◽  
pp. 874-881 ◽  
Author(s):  
Michael W.M. Gerrickens ◽  
Roel H.D. Vaes ◽  
Bastiaan Govaert ◽  
Magda van Loon ◽  
Jan H.M. Tordoir ◽  
...  
2019 ◽  
Vol 58 (6) ◽  
pp. e95
Author(s):  
Michael Gerrickens ◽  
Magda van Loon ◽  
Jan Tordoir ◽  
Frank van Hoek ◽  
Joep Teijink ◽  
...  

2014 ◽  
Vol 28 (5) ◽  
pp. 1315.e11-1315.e15 ◽  
Author(s):  
Francesco De Santis ◽  
Guido Martini ◽  
Gabriele Mani ◽  
Othmar Bernhard

Author(s):  
Sulav Bastola ◽  
William D Paulson ◽  
Steven A Jones

The native arteriovenous fistula creates a shunt that provides the high blood flow that is needed for dialysis. Lumped parameter hemodynamic models of the arteriovenous fistula can be used to predict shear stresses and pressure losses and can be applied to help understand unsolved problems such as the high rate of arteriovenous fistula maturation failure. These models combine together flow components, such as arteries, stenosis, anastomoses, arterial compliance, and blood inertia, and each component must be modeled with an appropriate pressure–flow relationship. Poiseuille flow is generally assumed for straight vessels, but the unique high flow rates within the brachial artery of an arteriovenous fistula are expected to induce entry flow effects that are neglected in this model. To estimate the importance of these effects, brachial artery flow was modeled in a low-resistance network, such as the one that occurs when an arteriovenous fistula is constructed, through the lumped parameter model, and the predicted flow rates and pressures were compared to those predicted by computational fluid dynamics. When Poiseuille flow was assumed, the flow rate from the lumped parameter model was consistently larger than that from computational fluid dynamics, with a cycle-averaged error of 36.8%. When an entry flow model (Shah) was assumed, the lumped parameter–based flow was 6% lower than the computational fluid dynamics model at the peak of the flow waveform, and the cycle-averaged error was reduced to 7.8%. Thus, in a low-resistance (high flow) arteriovenous fistula circuit, an entry flow model can account for steeper near-wall velocity gradients. This result can provide a useful guide for designing engineering models of the arteriovenous fistula.


2021 ◽  
pp. 112972982199398
Author(s):  
Miju Bae ◽  
Sung Woon Chung ◽  
Chung Won Lee ◽  
Up Huh ◽  
Moran Jin ◽  
...  

Background: Access-related hand ischemia (ARHI) is a major complication of arteriovenous fistula (AVF). This study aimed to assess the predictive efficacy of skin perfusion pressure (SPP) measurement for ARHI by examining the relationship between SPP and ARHI development and progression after AVF surgery. Methods: Twenty-five patients (16 men and 9 women) who underwent AVF surgery based on the brachial artery between January 2018 and December 2018 were included. The pre- and postoperative SPP values were measured on the day of surgery. ARHI occurrence and severity were measured within 3 days and at 6 months after surgery. Receiver operating characteristic curve analysis was used to evaluate the prediction model of ARHI, and the cutoff points for the calculated coefficients were determined. Results: There was a significant correlation between the occurrence of immediate ARHI and the SPP gradient ( p = 0.024). An SPP gradient value >50 mmHg had sensitivity and specificity values of 53.85% and 91.67%, respectively, in predicting the occurrence of immediate ARHI. A postoperative SPP <48 mmHg was significantly correlated with the occurrence of 6-month ARHI ( p = 0.005), with sensitivity and specificity values of 71.43% and 83.33%, respectively. Conclusion: The SPP gradient and postoperative SPP values may be effective clinical predictors of ARHI occurring immediately and 6 months after surgery, respectively, with high specificity. These findings could allow clinicians to diagnose and begin early interventions to help prevent ischemic tissue damage in hemodialysis patients following AVF surgery.


2019 ◽  
Vol 54 (1) ◽  
pp. 75-79
Author(s):  
Curtis Woodford ◽  
Elizabeth Tai ◽  
Sebastian Mafeld ◽  
Husain A. Al-Mubarak ◽  
Arash Jaberi ◽  
...  

Brachial artery aneurysms and arteriovenous malformations (AVM) are limb-threatening vascular anomalies. This patient presented with a bilobed brachial artery aneurysm in the antecubital fossa proximally to an AVM arising from the dorsal interosseous and ulnar arteries that had been treated with endovascular embolization, leaving the hand solely supplied by the radial artery. The aneurysm continued to increase in size and imaging revealed concomitant thrombus. A femoral vein interposition graft was used to repair the aneurysm, and postoperatively, the patient retained full left arm function.


2022 ◽  
pp. 112972982110676
Author(s):  
Rita Vicente ◽  
Laura Rodriguez ◽  
Joaquim Vallespín ◽  
Carolina Rubiella ◽  
Jose Ibeas

Vascular access thrombosis is an important complication with great impact on access patency and, consequently, on a patient’s quality of life and survival. We report the case of a 73-year-old woman with chronic kidney disease on hemodialysis with a radiocephalic arteriovenous fistula on the right arm that was brought to the emergency department with decreased strength in her right arm, ipsilateral hypoesthesia and facial hemi-hypoesthesia. The patient was given a brain computed tomographic scan that did not confirm suspicion of stroke. On re-examination, the patient had new-onset pain at arteriovenous fistula level, and her right arm was cold and pale. The nephrology department was called for arteriovenous fistula evaluation. On physical examination, her forearm fistula had a decreased thrill and arm elevation exacerbated its paleness. A bedside ultrasound was performed for arteriovenous fistula assessment. Doppler ultrasound revealed: partial thrombosis at brachial bifurcation, a flow of 80–105 mL/min at brachial artery level and a radial artery with a damped waveform. Anastomosis and draining vein were permeable. In this case, the diagnosis of acute embolic brachial artery occlusion was made by a fast bedside ultrasound evaluation. The patient underwent thromboembolectomy with Fogarty technique, recovering fistula thrill, radial and cubital pulses. Thromboembolism of the fistula feeding artery is a rare cause of vascular access thrombosis and it is rarely mentioned in the literature. In this report, failure to recognize the upper limb ischemia would have led to delayed treatment, potentially resulting in the fistula’s complete thrombosis and further limb ischemia. We highlight the importance of a diagnosis method like Doppler ultrasound, which allows for rapid evaluation at the patient’s bedside.


2003 ◽  
Vol 4 (1) ◽  
pp. 21-24 ◽  
Author(s):  
M. Onaran ◽  
D. Erer ◽  
I. Şen ◽  
E.E. Elnur ◽  
E. Iriz ◽  
...  

Background Although the best type of vascular access for chronic hemodialysis patients is a native arteriovenous fistula, in an increasing number of patients all the superficial veins have been used and only the placement of vascular grafts or permanent catheters is left. Superficialization of the basilic vein is a possible alternative. Materials and Methods In 49 chronic hemodialysis patients who had no possibilities to have a native arteriovenous fistula created, we performed a basilic vein- brachial artery fistula in the arm. During the same operation the basilic vein was then superficialized for easier access for hemodialysis. Results Mean follow-up was 22.36±15.56 months. Forty-eight patients are still undergoing hemodialysis with their superficialized basilic vein native A-V fistula without any complications. Only one fistula was thrombosed just after the procedure because of poor vessel quality. Conclusion For hemodialysis patients who have no suitable superficial veins at the wrist or elbow, performing a basilic vein - brachial artery fistula and superficializing the vein to the subcutaneous tissue is an acceptable choice before deciding to use more complicated procedures like vascular grafts.


2002 ◽  
Vol 8 (1) ◽  
pp. 55-60 ◽  
Author(s):  
C. Campos ◽  
R. Piske ◽  
J. Nunes ◽  
S.B. Soares ◽  
J.A. Castro ◽  
...  

A high flow pial arteriovenous fistula in a twenty-years-old girl is described. The arteriovenous communication corresponds to a single hole fistula on the right rolandic area, with a giant venous ectasia. The patient presented seizures and left hemiparesis as symptoms. The fistula was embolized with glue obtaining total occlusion of the shunt. Hypotension was induced and valsalva manoeuver was done during the glue injection to reduce the flow into the fistula, however 26 hours after the procedure the patient bled resulting in a fatal outcome. The purpose of this paper is discuss the presentation of Rendu-Osler-Weber (ROW) in children and the therapeutic guidelines.


2018 ◽  
Vol 58 (10) ◽  
pp. 211-214
Author(s):  
Ippei Kato ◽  
Tomohiro Iwakura ◽  
Koji Toguchi ◽  
Noriko Asakawa

Sign in / Sign up

Export Citation Format

Share Document