Left ventricular assist device in Duchenne Cardiomyopathy: Can we change the natural history of cardiac disease?

2012 ◽  
Vol 161 (3) ◽  
pp. e43 ◽  
Author(s):  
Antonio Amodeo ◽  
Rachele Adorisio
2020 ◽  
pp. 089719002093053 ◽  
Author(s):  
Hasan Kazmi ◽  
Ashley E. Milkovits

The use of systemic bivalirudin and an anticoagulant-free purge solution in a percutaneous left ventricular assist device (pVAD) is described in a patient with a history of heparin-induced thrombocytopenia (HIT). An 80-year-old man with a past medical history of severe aortic stenosis and HIT was transferred to our facility for cardiogenic shock. The patient was emergently taken to the cardiac catheterization laboratory for balloon valvuloplasty and Impella pVAD (Abiomed, Inc) implantation. Due to the history of HIT, bivalirudin was chosen as an alternative anticoagulant. The device representative suggested adding bivalirudin 20 mg/500 mL to the Impella purge solution. However, due to the negligible amount of bivalirudin this would provide in comparison to patient’s systemic intravenous bivalirudin dose, we elected not to add bivalirudin to the purge solution. The patient remained on the Impella for 72 hours with intravenous bivalirudin without any evidence of pump thrombosis as evidenced by unchanging flows and stable purge pressures. Unfortunately, despite functional Impella pVAD support, care was withdrawn due to ongoing multi-organ failure. This patient case demonstrated the safe, effective, and practical use of an anticoagulant-free purge solution with systemic bivalirudin in a patient with 72 hours of Impella support.


2020 ◽  
Vol 35 (9) ◽  
pp. 2224-2231 ◽  
Author(s):  
Yeahwa Hong ◽  
Laura Seese ◽  
Gavin Hickey ◽  
Shangzhen Chen ◽  
Michael A. Mathier ◽  
...  

2020 ◽  
Vol 31 (1) ◽  
pp. 1-8
Author(s):  
Brian C Ayers ◽  
Katherine Wood ◽  
Scott McNitt ◽  
Ilan Goldenberg ◽  
Leway Chen ◽  
...  

Abstract OBJECTIVES History of prior cardiac surgery has traditionally been considered a risk factor for subsequent cardiac procedures. The aim of this study was to investigate the outcomes of patients implanted with a left ventricular assist device via redo sternotomy. METHODS Prospectively collected data were reviewed for all patients implanted with a continuous-flow left ventricular assist device at a single institution from December 2006 through June 2018. Patients were separated into 2 cohorts: those with a history of prior cardiac surgery (redo sternotomy) and those undergoing primary sternotomy at the time of left ventricular assist device implantation. The primary outcome was overall survival. RESULTS Of the 321 patients included in the study, 77 (24%) were implanted via redo sternotomy and 244 (76%) via primary sternotomy. The redo sternotomy cohort was generally older (59 ± 10 vs 57 ± 12 years, P = 0.050) and had a higher incidence of ischaemic disease (70% vs 49%, P = 0.002). The Kaplan–Meier survival analysis demonstrated that overall survival was not significantly different between the redo sternotomy and primary sternotomy groups (6-month survival: 86% vs 92%; 5-year survival: 53% vs 51%; log-rank P = 0.590 for overall difference during follow-up). The propensity score analysis consistently showed that redo sternotomy was not significantly associated with mortality risk (hazard ratio 1.19, 95% confidence interval 0.73–1.93; P = 0.488). Redo sternotomy patients were more likely to require rehospitalization during their first year postoperatively (P = 0.020) and spent less time out of the hospital during the first year (P = 0.046). CONCLUSIONS The redo sternotomy cohort represents a more technically challenging patient population, but overall survival similar to that of primary sternotomy patients can be achieved.


Author(s):  
Brian Ayers ◽  
Fabio Sagebin ◽  
Katherine Wood ◽  
Bryan Barrus ◽  
Sabu Thomas ◽  
...  

Objective Early reports of less invasive techniques for left ventricular assist device (LVAD) implantation have demonstrated promising results. We sought to investigate the safety and feasibility of implementing the complete sternal-sparing (CSS) approach for LVAD implantation in patients with a history of prior cardiac operation. Methods This was a retrospective review of prospectively collected data for all patients implanted with a fully magnetically levitated LVAD from April 2017 through December 2018. Patients were dichotomized based on surgical approach: CSS or full median sternotomy (FS). Perioperative complications and overall survival were compared between cohorts. Results Of the 29 eligible patients, 15 (52%) were implanted via the CSS approach and 14 (48%) via FS. Preoperative characteristics were similar between cohorts. Overall survival to discharge was 93% for CSS compared to 71% for FS ( P = 0.169). The CSS cohort demonstrated fewer postoperative complications, including fewer cases of severe right ventricular failure ( P = 0.006) and less blood product utilization ( P = 0.015). Median hospital length of stay was significantly shorter for the CSS cohort (median 13 vs 32.5 days, P = 0.016). Neither cohort had any 30-day readmissions. Conclusions Early data suggest that the CSS technique is a safe and effective technique for patients with a history of prior sternotomy. Further studies are needed to validate this single-center experience.