scholarly journals TCT-601 Focused Balloon Pulmonary Angioplasty for Truly Non-surgical Chronic Thromboembolic Pulmonary Hypertension – the UK experience

2017 ◽  
Vol 70 (18) ◽  
pp. B248
Author(s):  
Stephen Hoole ◽  
Gerry Coghlan ◽  
John Cannon ◽  
Joanna Pepke-Zaba
Open Heart ◽  
2020 ◽  
Vol 7 (1) ◽  
pp. e001144 ◽  
Author(s):  
Stephen P Hoole ◽  
John G Coghlan ◽  
John E Cannon ◽  
Dolores Taboada ◽  
Mark Toshner ◽  
...  

ObjectiveInoperable chronic thromboembolic pulmonary hypertension (CTEPH) managed medically has a poor prognosis. Balloon pulmonary angioplasty (BPA) offers a new treatment for inoperable patients. The national BPA service for the UK opened in October 2015 and we now describe the treatment of our initial patient cohort.MethodsThirty consecutive, inoperable, anatomically suitable, symptomatic patients on stable medical therapy for CTEPH were identified and offered BPA. They initially underwent baseline investigations including Cambridge Pulmonary Hypertension Outcome Review (CAMPHOR) quality of life (QoL) questionnaire, cardiopulmonary exercise test, 6 min walk distance (6MWD), transthoracic echocardiography, N-terminal probrain natriuretic peptide (NT pro-BNP) and right heart catheterisation. Serial BPA sessions were then performed and after completion, the treatment effect was gauged by comparing the same investigations at 3 months follow-up.ResultsA median of 3 (IQR 1–6) BPA sessions per patient resulted in a significant improvement in functional status (WHO functional class ≥3: 24 vs 4, p<0.0001) and QoL (CAMPHOR symptom score: 8.7±5.4 vs 5.6±6.1, p=0.0005) with reductions in pulmonary pressures (mean pulmonary artery pressure: 44.7±11.0 vs 34.4±8.3 mm Hg, p<0.0001) and resistance (pulmonary vascular resistance: 663±281 vs 436±196 dyn.s.cm-5, p<0.0001). Exercise capacity improved (minute ventilation/carbon dioxide production: 55.3±12.2 vs 45.0±7.8, p=0.03 and 6MWD: 366±107 vs 440±94 m, p<0.0001) and there was reduction in right ventricular (RV) stretch (NT pro-BNP: 442 (IQR 168–1607) vs 202 (IQR 105–447) pg/mL, p<0.0001) and dimensions (mid RV diameter: 4.4±1.0 vs 3.8±0.7 cm, p=0.002). There were no deaths or life-threatening complications and the mild-moderate per-procedure complication rate was 10.5%.ConclusionsBPA is safe and improves the functional status, QoL, pulmonary haemodynamics and RV dimensions of patients with inoperable CTEPH.


Diagnostics ◽  
2021 ◽  
Vol 11 (1) ◽  
pp. 133
Author(s):  
Marta Banaszkiewicz ◽  
Arkadiusz Pietrasik ◽  
Michał Florczyk ◽  
Piotr Kędzierski ◽  
Michał Piłka ◽  
...  

Background: The aim of the study was to assess soluble ST2 (sST2) concentration and its dynamic changes in the periprocedural period in patients with chronic thromboembolic pulmonary hypertension (CTEPH) treated with balloon pulmonary angioplasty (BPA). Methods: We prospectively analyzed 57 procedures of BPA performed in 37 patients with CTEPH. Biomarkers, such as N-terminal pro B-type natriuretic peptide (NT-proBNP), troponin T (TnT), and sST2 were assessed at four time points: Before the BPA procedure, 24 h and 48 h after the procedure, and at the discharge from hospital. Each postprocedural period was assessed for complications. Results: Before the BPA procedure, median sST2 concentration was 26.56 ng/mL (IQR: 16.66–40.83 ng/mL). sST2 concentration was significantly higher 24 h and 48 h after the BPA compared to the baseline measurements (33.31 ng/mL (IQR: 20.81–62.56), p = 0.000 and 27.45 ng/mL (IQR: 17.66–54.45), p = 0.028, respectively). sST2 level 24 h after the BPA procedure was significantly higher in the group with complications compared to the group without complications in the postprocedural period (97.66 ng/mL (IQR: 53.07–126.18) vs. 26.86 ng/mL (IQR: 19.10–40.12), p = 0.000). Conclusions: sST2 concentration in patients with CTEPH treated with BPA changes significantly in the postprocedural period and is significantly higher in the group with complications in postprocedural period.


Sign in / Sign up

Export Citation Format

Share Document