Clinical outcomes and rotational stability of a 4-haptic toric intraocular lens in myopic eyes

2014 ◽  
Vol 40 (9) ◽  
pp. 1479-1487 ◽  
Author(s):  
Rita Mencucci ◽  
Eleonora Favuzza ◽  
Francesca Guerra ◽  
Giovanni Giacomelli ◽  
Ugo Menchini
2021 ◽  
pp. 112067212110464
Author(s):  
Oya Donmez ◽  
Bilgehan Sezgin Asena ◽  
Yonca Aydin Akova

Purpose: To evaluate the clinical outcomes and quality of life following implantation of PanOptix toric intraocular lens (IOL) and to compare the outcomes following femtosecond laser assisted cataract surgery (FLACS) and standard cataract surgery (SCS). Methods: This comparative retrospective study included 79 eyes of 55 patients underwent cataract or refractive lens exchange surgery between April 2017 and January 2020 in Bayindir Hospital and Kaskaloglu Eye Hospital. Corneal (CA) and refractive astigmatism (RA), uncorrected visual acuities for distant, intermediate, and near (UDVA, UIVA, and UNVA), low contrast distance visual acuity, rotational stability, defocus curves, photopic and mesopic contrast sensitivity (CS), visual function-14 (VF-14) test, presence of dysphotopsia, and need for spectacles were evaluated at postoperative third month. Outcomes were compared between FLACS and SCS group. Results: The mean UDVA, UIVA, and UNVA were 0.05 ± 0.07, 0.08 ± 0.08, and 0.06 ± 0.07 logMAR, respectively. All patients achieved ⩾0.3 logMAR uncorrected visual acuity for all distances. UDVA was found significantly better in FLACS group ( p = 0.03). All eyes had ⩽1 D of subjective postoperative RA. Defocus curve had two peaks at 0 and −1.50 D. Spectacle independence was achieved in 88.7% of patients. Photopic and mesopic CS was within normal range in all patients. The mean VF-14 score was 98 ± 2. The mean IOL axis rotation was 2.1° ± 2.3°. Only one patient reported seeing disturbing halos. Conclusions: This trifocal toric IOL effectively reduced refractive astigmatism and provided excellent visual outcomes with high spectacle independence, patients’ satisfaction, and good rotational stability. FLACS might have an impact on optimal postoperative results.


2017 ◽  
Vol 102 (3) ◽  
pp. 313-316 ◽  
Author(s):  
Bettina C Thomas ◽  
Ramin Khoramnia ◽  
Gerd U Auffarth ◽  
Mike P Holzer

PurposeTo evaluate the postoperative outcomes after implantation of a hydrophilic toric intraocular lens (tIOL) with a transitional conic toric surface in patients with astigmatism undergoing refractive lens exchange (RLE) or cataract surgery.MethodsIn this monocentric study, clinical outcomes following implantation of the hydrophilic Precizon toric IOL model 565 (Ophtec) were analysed. For intraoperative axis alignment, the Verion Image Guided System was used. Intended versus achieved refraction, IOL position, visual acuity outcomes and power vector analyses were evaluated 3 months postoperatively.ResultsForty-three eyes of 28 patients (40 eyes cataract, 3 eyes RLE) received a Precizon toric IOL with a cylindrical power between 1.0 and 7.5 D. Target refraction was emmetropia except for four eyes that had a myopic target. The median postoperative IOL rotation at slit lamp was 3° with a range from 0° to 16°. Uncorrected distance visual acuity (UDVA) increased from median 0.5 logMAR preoperatively to median 0.06 logMAR at 3 months postoperatively. Corrected distance visual acuity increased from 0.20 to −0.02 logMAR. Median preoperative subjective cylinder was 1.5 D and 3 months postoperatively 0.25 D.ConclusionPreoperative diagnostics, IOL selection and correct intraoperative positioning of tIOLs are essential for good outcomes and postoperative spectacle independence following cataract or RLE surgery. Visual acuities and rotational stability of the Precizon toric IOL showed very good outcomes and the subjective postoperative astigmatism could be reduced significantly.


2016 ◽  
Vol 32 (7) ◽  
pp. 444-450 ◽  
Author(s):  
Eduardo F. Marques ◽  
Tiago B. Ferreira ◽  
Pedro Simões

2020 ◽  
Vol 36 (3) ◽  
pp. 186-192 ◽  
Author(s):  
Magdaléna Vokrojová ◽  
Lenka Havlíčková ◽  
Markéta Brožková ◽  
Zuzana Hlinomazová

2014 ◽  
Vol 99 (3) ◽  
pp. 405-411 ◽  
Author(s):  
Florian T A Kretz ◽  
Antoine Bastelica ◽  
Humberto Carreras ◽  
Tiago Ferreira ◽  
Matthias Müller ◽  
...  

2020 ◽  
Vol Publish Ahead of Print ◽  
Author(s):  
Koh Sasaki ◽  
Shuichiro Eguchi ◽  
Akira Miyata ◽  
Tomohisa Nishimura ◽  
Kazunori Miyata ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document