Tomographic analysis of anterior and posterior surgically induced astigmatism after 2.2 mm temporal clear corneal incisions in femtosecond laser–assisted cataract surgery

2019 ◽  
Vol 45 (11) ◽  
pp. 1602-1611
Author(s):  
Thomas Kohnen ◽  
Franziska Löffler ◽  
Michael Herzog ◽  
Kerstin Petermann ◽  
Myriam Böhm
2020 ◽  
Vol 13 (12) ◽  
pp. 1895-1900
Author(s):  
Wei Chen ◽  
Jian Wu ◽  
Yong Wang ◽  
Jing Zhou ◽  
Rong-Rong Zhu ◽  
...  

AIM: To investigate the clinical efficacy and safety of femtosecond laser-assisted steepest-meridian clear corneal incisions for correcting preexisting corneal astigmatism performed at the time of cataract surgery. METHODS: This prospective case series study comprised consecutive age-related cataract patients with corneal regular astigmatism (range: +0.75 to +2.50 D) who had femtosecond laser-assisted steepest-meridian clear corneal incisions (single or paired). Corneal astigmatism was performed with the Pentacam preoperatively and 3mo postoperatively. Total corneal astigmatism and steepest-meridian measured in the 3-mm central zone were used to guide the location, size and number of clear corneal incision. The vector analysis of astigmatic change was performed using the Alpins method. RESULTS: Totally 138 eyes of 138 patients were included. The mean preoperative corneal astigmatism was 1.31±0.41 D, and was significantly reduced to 0.69±0.34 D (equivalent to difference vector) after surgery (P<0.01). The surgically-induced astigmatism was 1.02±0.54 D. The correction index (ratio of target induced astigmatism and surgically-induced astigmatism: 0.72±0.36) as well as the magnitude of error (difference between surgically-induced astigmatism and target induced astigmatism: -0.29±0.51) represented a slight under correction. For angle of error, the arithmetic mean was 1.11±13.70, indicating no significant systematic alignment errors. CONCLUSION: Femtosecond-assisted steepest-meridian clear corneal incision is a fast, customizable, adjustable, precise, and safe technique for the reduction of low to moderate corneal astigmatism during cataract surgery.


2015 ◽  
Vol 41 (10) ◽  
pp. 2075-2080 ◽  
Author(s):  
Vasilios F. Diakonis ◽  
Nilufer Yesilirmak ◽  
Florence Cabot ◽  
Vardhaman P. Kankariya ◽  
George A. Kounis ◽  
...  

2018 ◽  
Vol 28 (4) ◽  
pp. 398-405 ◽  
Author(s):  
Joaquín Fernández ◽  
Manuel Rodríguez-Vallejo ◽  
Javier Martínez ◽  
Ana Tauste ◽  
David P Piñero

Purpose: To assess the surgically induced astigmatism with femtosecond laser-assisted and manual temporal clear corneal incisions and to evaluate the performance of a model for prediction of the surgically induced astigmatism based on the preoperative corneal astigmatism. Methods: Clinical data of 104 right eyes and 104 left eyes undergoing cataract surgery, 52 with manual incisions and 52 with femtosecond laser-assisted incisions in each eye group, were extracted and revised retrospectively. In all cases, manual incisions were 2.2 mm width and femtosecond incisions were 2.5 mm width, both at temporal location. A predictive model of the surgically induced astigmatism was obtained by means of simple linear regression analyses. Results: Mean surgically induced astigmatisms for right eyes were 0.14D@65° (manual) and 0.24D@92° (femtosecond) (p > 0.05) and for left eyes, 0.15D@101° (manual) and 0.19D@104° (femtosecond) (p > 0.05). The orthogonal components of the surgically induced astigmatism (XSIA, YSIA) were significantly correlated (p < 0.05) with the preoperative orthogonal components of corneal astigmatism (Xpreop, Ypreop) (r = −0.29 for X and r = −0.1 for Y). The preoperative astigmatism explained 8% of the variability of the XSIA and 3% of the variability of YSIA. The postoperative corneal astigmatism prediction was not improved by the surgically induced astigmatism obtained from the model in comparison with the simple vector subtraction of the mean surgically induced astigmatism. Conclusion: Temporal incisions induce similar astigmatism either for manual or for femtosecond procedures. This can be clinically negligible for being considered for toric intraocular lens calculation due to the great standard deviation in comparison with the mean. The usefulness of the prediction model should be confirmed in patients with high preoperative corneal astigmatism.


2011 ◽  
Vol 2011 ◽  
pp. 1-4 ◽  
Author(s):  
Paul Ernest ◽  
Warren Hill ◽  
Richard Potvin

Purpose. To compare the surgically induced astigmatism from clear corneal and square posterior limbal incisions at the time of cataract surgery.Methods. Surgically induced astigmatism was calculated for a set of eyes after cataract surgery using a temporal 2.2 mm square posterior limbal incision. Results were compared to similar available data from surgeons using clear corneal incisions of similar size.Results. Preoperative corneal astigmatism averaged 1.0 D and was not significantly different between the incision types. Surgically induced astigmatism with the 2.2 mm posterior limbal incision averaged0.25±0.14 D, significantly lower in magnitude than the aggregate surgically induced astigmatism produced by the 2.2 mm clear corneal incision (0.68±0.49 D).Conclusion. The 2.2 mm square posterior limbal incision induced significantly less, and significantly less variable, surgically induced astigmatism relative to a similar-sized clear corneal incision. This is likely to improve refractive outcomes, particularly important with regard to premium intraocular lenses.


Sign in / Sign up

Export Citation Format

Share Document