The Effect of Distal Radius Fractures on 3-Dimensional Joint Congruency

2021 ◽  
Vol 46 (1) ◽  
pp. 66.e1-66.e10
Author(s):  
Emily A. Lalone ◽  
Joy MacDermid ◽  
Graham King ◽  
Ruby Grewal
1996 ◽  
Vol 21 (1) ◽  
pp. 40-47 ◽  
Author(s):  
Hitoshi Kihara ◽  
Andrew K. Palmer ◽  
Frederick W. Werner ◽  
Walter H. Short ◽  
Maria D. Fortino

2020 ◽  
Vol 45 (3) ◽  
pp. 189-195
Author(s):  
C.A. Selles ◽  
M.S.H. Beerekamp ◽  
P.A. Leenhouts ◽  
M.J.M. Segers ◽  
J.C. Goslings ◽  
...  

Author(s):  
Laura A. Hruby ◽  
Thomas Haider ◽  
Roberta Laggner ◽  
Claudia Gahleitner ◽  
Jochen Erhart ◽  
...  

Abstract Introduction Distal radius fractures account for one-fifth of all fractures in the emergency department. Their classification based on standard radiographs is common practice although low inter-observer reliabilities and superiority of computer tomography (CT) scanning in evaluation of joint congruency have been reported. Materials and methods We retrospectively analyzed 96 displaced distal radius fractures scheduled for open reduction and internal fixation using standard radiographic assessment. The radiographs were classified with the Arbeitsgemeinschaft für Osteosynthesefragen/Orthopaedic Trauma Association (AO/OTA), Fernandez and Frykman classifications by three observers and inter-rater reliabilities were calculated. Additional CT scanning was performed in all cases and the following parameters were assessed: radiocarpal joint involvement, fracture extent into the radial sigmoid notch, i.e. the distal radio-ulnar joint, comminution of the metaphysis, and concomitant ulnar styloid fracture. The CT scans were used as a reference standard to determine sensitivity and accuracy of standard radiographic assessment in evaluation of distal radius fractures. Results The inter-rater agreement for the AO classification was 35.4%, 68.8% for the Fernandez and 38.5% for the Frykman classification. Fracture extension into the radiocarpal joint was present in 81 cases (84.4%). Sigmoid notch involvement was found in 81 fractures (84.4%). Involvement of both joints was present in 72 cases (75%). The sensitivity of standard radiographs regarding radiocarpal joint involvement was 93.8%. Considering involvement of the distal radio-ulnar joint the false-negative rate using standard radiographs was 61.7% and the test’s accuracy for sigmoid notch involvement was 45.8%. Conclusion This study demonstrates that involvement of the sigmoid notch is frequently missed in standard radiographs. The presented data support the frequent use of CT imaging to allow the holistic illustration of a fracture’s complexion and to ensure optimal pre-operative planning.


2015 ◽  
Vol 04 (S 01) ◽  
Author(s):  
Masao Nishiwaki ◽  
Mark Welsh ◽  
Louis Ferreira ◽  
James Johnson ◽  
Graham King ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document