Reconstruction of Digit Soft Tissue Defects With the Fourth Common Digital Artery Perforator Flap

Author(s):  
Bauback Safa ◽  
Dong Chul Lee ◽  
Jinha Park ◽  
Sung Hoon Koh ◽  
Jin Soo Kim ◽  
...  
BMC Surgery ◽  
2019 ◽  
Vol 19 (1) ◽  
Author(s):  
Haoliang Hu ◽  
Hong Chen ◽  
Jinjiong Hong ◽  
Weisheng Mao ◽  
Mintao Tian ◽  
...  

Abstract Background When restoring the appearance and function of the fingers, hand surgeons face a challenge in choosing a suitable surgical method to repair finger skin defects. Methods In this study, we designed a long elliptical flap based on a propeller perforator flap and located slightly toward the dorsal lateral aspect of the finger. The flap with a pedicle consisting of the dorsal perforator of the distal digital artery and dorsal digital artery perforator chain is rotated to cover a large wound on the distal end. From December 2014 to December 2017, 10 patients with finger soft tissue defects were treated with the propeller perforator flap described in this study. Results All flaps survived after surgery, and 2 had a transient venous congestion. After a follow-up period of 3 to 12 months, the static two-point discrimination of the flap was 8.06 ± 1.75 mm, and the range of motion was 149.4 ± 12.9°. This designed flap can span several angiosomes supplied by the perforators. Due to the inclusion of a vessel chain between the dorsal digital artery perforators, the length-to-width ratio of the flap can be up to 3:1. Conclusions This technique increases the size of flap that can be harvested safely while retaining a reliable blood supply. The present study describes a new method for repairing soft tissue defects of the finger by using the technique of propeller perforator flaps based on dorsal digital artery perforator chains. Trial registration The registration number of this study is ChiCTR1800014588; it has been retrospectively registered with Chinese Clinical Trial Registry (chictr.org.cn), 18/11/2019.


2020 ◽  
Vol Publish Ahead of Print ◽  
Author(s):  
Qiang Xu ◽  
Shou-Cheng Yin ◽  
Xing-Zhou Su ◽  
Si-Min Wang ◽  
Yi-Hao Liu ◽  
...  

2007 ◽  
Vol 32 (5) ◽  
pp. 512-517 ◽  
Author(s):  
R. G. XIE ◽  
J. H. GU ◽  
Y. P. GONG ◽  
J. B. TANG

We report our experience of using the medial sural artery perforator flap in the reconstruction of soft tissue defects in the hand in seven cases with 1 to 2 year follow-up. The flap is harvested from the posteromedial aspect of the leg, just below the knee and superficial to the medial head of the gastrocnemius muscle. It is based on the perforator arteries and veins supplied by the medial sural artery. The flaps ranged in size from 14 × 10 cm to 8 × 6 cm. The donor area was closed directly or by a skin graft. All but one flap survived. The cosmetic results were satisfactory and without apparent bulkiness. Similarity of colour and thickness of the donor and recipient sites are advantages. We feel that this new flap is a satisfactory option for use in the hand, particularly for extended soft tissue defects on the dorsal hand.


Sign in / Sign up

Export Citation Format

Share Document