Two-phase modeling of gas purge in a polymer electrolyte fuel cell

2008 ◽  
Vol 183 (2) ◽  
pp. 609-618 ◽  
Author(s):  
Puneet K. Sinha ◽  
Chao-Yang Wang
2007 ◽  
Vol 154 (11) ◽  
pp. B1158 ◽  
Author(s):  
Puneet K. Sinha ◽  
Chao-Yang Wang

Author(s):  
Agus P. Sasmito ◽  
Tariq Shamim ◽  
Erik Birgersson ◽  
Arun S. Mujumdar

In open-cathode polymer electrolyte fuel cell (PEFC) stacks, a significant temperature rise can exist due to insufficient cooling, especially at higher current densities. To improve stack thermal management while reducing the cost of cooling, we propose a forced air-convection open-cathode fuel cell stack with edge cooling (fins). The impact of the edge cooling is studied via a mathematical model of the three-dimensional two-phase flow and the associated conservation equations of mass, momentum, species, energy, and charge. The model includes the stack, ambient, fan, and fins used for cooling. The model results predict better thermal management and stack performance for the proposed design as compared to the conventional open-cathode stack design, which shows potential for practical applications. Several key design parameters—fin material and fin geometry—are also investigated with regard to the stack performance and thermal management.


Author(s):  
M. Vynnycky ◽  
A. Gordon

An anomaly in the modelling of two-phase flow in the porous cathode gas diffusion layer (GDL) of a polymer electrolyte fuel cell is investigated asymptotically and numerically. Although not commented on previously in literature, the generalized Darcy model used most commonly leads to the surprising prediction that a hydrophilic GDL can lead to better cell performance, in terms of current density, than a hydrophobic one. By analysing a reduced one-dimensional steady-state model and identifying the capillary number as a small dimensionless parameter, we find a potential flaw in the original model, associated with the constitutive relation linking the capillary pressure and the pressures of the wetting and non-wetting phases. Correcting this, we find that, whereas a hydrophilic GDL can sustain a two-phase (gas/liquid) region near the water-producing catalytic layer and gas phase only region further away, a hydrophobic GDL cannot; furthermore, hydrophobic GDLs are found to lead to better cell performance than hydrophilic GDLs, as is indeed experimentally the case.


Author(s):  
Yun Wang ◽  
Ken S. Chen

A multi-dimensional mathematical model is formulated for simulating the transport and electrochemical reaction phenomena in a polymer electrolyte fuel cell (PEFC). The model describes the two-phase flows, electrochemical reaction kinetics, species transport, and heat transfer, as well as their intrinsic couplings within a PEFC. Two-dimensional model predictions are computed for the two typical operating temperatures at 40 and 80 °C. Computed results reveal that liquid water level may be lower at the higher temperature operation due to water vapor phase diffusion. Detailed water and temperature distributions are displayed to explain the water and heat transport and their interaction. The computed water-content profiles are compared with available experimental data obtained by neutron imaging.


2019 ◽  
Vol 11 (1) ◽  
pp. 1535-1544 ◽  
Author(s):  
Puneet Sinha ◽  
Chao-Yang Wang

Author(s):  
Agus Pulung Sasmito ◽  
Tariq Shamim ◽  
Erik Birgersson ◽  
Arun Sadashiv Mujumdar

In open-cathode polymer electrolyte fuel cell (PEFC) stacks, a significant temperature rise can exist due to insufficient cooling, especially at higher current densities. To improve stack thermal management whilst reducing the cost for cooling, we propose a forced air-convection open-cathode fuel cell stack with edge cooling (fins). The impact of the edge cooling is studied via mathematical model of the three-dimensional two-phase flow and associated conservation equations of mass, momentum, species, energy and charge. The model includes stack, ambient, fan and fins used for cooling. The model results predict better thermal management and stack performance for the proposed design as compared to the conventional open-cathode stack design, which shows potential for practical application. Several key design parameters — fin material and fin geometry — are also investigated with regards to the stack performance and thermal management.


Sign in / Sign up

Export Citation Format

Share Document