Hygroscopic growth of atmospheric aerosol particles based on lidar, radiosonde, and in situ measurements: Case studies from the Xinzhou field campaign

Author(s):  
Min Lv ◽  
Dong Liu ◽  
Zhanqing Li ◽  
Jietai Mao ◽  
Yele Sun ◽  
...  
2006 ◽  
Vol 6 (12) ◽  
pp. 4519-4527 ◽  
Author(s):  
H. Wex ◽  
A. Kiselev ◽  
M. Ziese ◽  
F. Stratmann

Abstract. A calibration for LACIS (Leipzig Aerosol Cloud Interaction Simulator) for its use as a CCN (cloud condensation nuclei) detector has been developed. For this purpose, sodium chloride and ammonium sulfate particles of known sizes were generated and their grown sizes were detected at the LACIS outlet. From these signals, the effective critical super-saturation was derived as a function of the LACIS wall temperature. With this, LACIS is calibrated for its use as a CCN detector. The applicability of LACIS for measurements of the droplet activation, and also of the hygroscopic growth of atmospheric aerosol particles was tested. The activation of the urban aerosol particles used in the measurements was found to occur at a critical super-saturation of 0.46% for particles with a dry diameter of 75 nm, and at 0.42% for 85 nm, respectively. Hygroscopic growth was measured for atmospheric aerosol particles with dry diameters of 150, 300 and 350 nm at relative humidities of 98 and 99%, and it was found that the larger dry particles contained a larger soluble volume fraction of about 0.85, compared to about 0.6 for the 150 nm particles.


2009 ◽  
Vol 2 (2) ◽  
pp. 1057-1073
Author(s):  
E. Nilsson ◽  
E. Swietlicki ◽  
S. Sjogren ◽  
J. Löndahl ◽  
M. Nyman ◽  
...  

Abstract. A new hygroscopic tandem differential mobility analyzer (H-TDMA) has been constructed at Lund University within the frameworks of the EU FP6 Infrastructure Project EUSAAR (http://www.eusaar.org/). The aim of this coordinated H-TDMA development is to design and evaluate a new generation of H-TDMAs that are capable of conducting long term measurements of the hygroscopic growth and state of mixing of sub-micrometer atmospheric aerosol particles at the EUSAAR aerosol super-sites across Europe. The H-TDMA constructed for this project has been validated with respect to hygroscopic growth factor, stability of relative humidity (RH), temperature stability and its ability to operate unattended for longer periods of time. When measuring growth factors of ammonium sulphate, the new H-TDMA system was found to measure within a growth factor deviation of ±0.05 compared to previously recorded data by Tang et al. (1994). The long term RH of the system has been found stable at 90.0% with a standard deviation of ±0.23% and an average temperature variability of the second DMA less than ±0.1 K. Daily automated ammonium sulphate measurements have validated the ambient measurements. The instrument is operated at the EMEP/EUSAAR background station Vavihill in the southern part of Sweden.


2009 ◽  
Vol 2 (1) ◽  
pp. 313-318 ◽  
Author(s):  
E. Nilsson ◽  
E. Swietlicki ◽  
S. Sjogren ◽  
J. Löndahl ◽  
M. Nyman ◽  
...  

Abstract. A new hygroscopic tandem differential mobility analyzer (H-TDMA) has been constructed at Lund University within the frameworks of the EU FP6 Infrastructure Project EUSAAR (http://www.eusaar.org/). The aim of this coordinated H-TDMA development is to design and evaluate a new generation of H-TDMAs that are capable of conducting long term measurements of the hygroscopic growth and state of mixing of sub-micrometer atmospheric aerosol particles at the EUSAAR aerosol super-sites across Europe. The H-TDMA constructed for this project has been validated with respect to hygroscopic growth factor, stability of relative humidity (RH), temperature stability and its ability to operate unattended for longer periods of time. When measuring growth factors of ammonium sulphate, the new H-TDMA system was found to measure within a growth factor deviation of ±0.05 compared to previously recorded data by Tang et al. (1994). The long term RH of the system has been found stable at 90.0% with a standard deviation of ±0.23% and an average temperature variability of the second DMA less than ±0.1 K. Daily automated ammonium sulphate measurements have validated the ambient measurements. The instrument is operated at the EMEP/EUSAAR background station Vavihill in the southern part of Sweden.


2006 ◽  
Vol 6 (4) ◽  
pp. 5877-5904
Author(s):  
H. Wex ◽  
A. Kiselev ◽  
M. Ziese ◽  
F. Stratmann

Abstract. A calibration for LACIS (Leipzig Aerosol Cloud Interaction Simulator) for its use as a CCN (cloud condensation nuclei) detector has been developed. For this purpose, sodium chloride and ammonium sulfate particles of known sizes were generated and their grown sizes were detected at the LACIS outlet. From these signals, the effective critical super-saturation was derived as a function of the LACIS wall temperature. With this, LACIS is calibrated for its use as a CCN detector. The applicability of LACIS for measurements of the droplet activation, and also of the hygroscopic growth of atmospheric aerosol particles was tested. The activation of the urban aerosol particles used in the measurements was found to occur at a critical super-saturation of 0.46% for particles with a dry diameter of 75 nm, and at 0.42% for 85 nm, respectively. Hygroscopic growth was measured for atmospheric aerosol particles with dry diameters of 150, 300 and 350 nm at relative humidities of 98 and 99%, and it was found that the larger dry particles contained a larger soluble volume fraction of about 0.85, compared to about 0.6 for the 150 nm particles.


Sign in / Sign up

Export Citation Format

Share Document