Open hemiarch versus clamped ascending aorta replacement for aortopathy during initial bicuspid aortic valve replacement

2021 ◽  
Vol 161 (1) ◽  
pp. 12-20.e2 ◽  
Author(s):  
Kevin L. Greason ◽  
Juan A. Crestanello ◽  
Katherine S. King ◽  
Gabor Bagameri ◽  
Sertac M. Cicek ◽  
...  
2021 ◽  
Vol 13 (3) ◽  
pp. 1531-1542
Author(s):  
Yaojun Dun ◽  
Yi Shi ◽  
Hongwei Guo ◽  
Yanxiang Liu ◽  
Xiangyang Qian ◽  
...  

Author(s):  
Antonio Lio ◽  
Matteo Ferrarini ◽  
Antonio Miceli ◽  
Mattia Glauber

A significant proportion of patients undergoing aortic valve replacement have a dilated ascending aorta; presence of an ascending aorta aneurysm is viewed as a contraindication for sutureless valve implantation for the potential risk of prosthesis dislodgment. We describe our technique of sutureless prosthesis implantation and concomitant ascending aorta replacement through an upper ministernotomy. Seven patients underwent aortic valve replacement with a sutureless prosthesis and concomitant ascending aorta replacement between November 2014 and October 2016. A J-shaped upper ministernotomy was performed in all patients. Diameter of vascular graft for the replacement of the dilated ascending aorta was chosen according to the size of the selected prosthesis, to recreate a ratio between diameters of the new sinotubular junction and the aortic annulus that should be less than 1.3. Postoperatively. no patient died in hospital. No paravalvular leakage or prosthesis dislodgment was reported. Mean ± SD cardiopulmonary bypass and cross-clamp times were 142 ± 52 minutes and 85 ± 18 minutes, respectively. In patients undergoing aortic valve replacement and ascending aorta replacement, sutureless valve implantation is a safe and reproducible procedure associated with good postoperative results.


Author(s):  
Alessandro Verzini ◽  
Marta Bargagna ◽  
Guido Ascione ◽  
Alessandra Sala ◽  
Davide Carino ◽  
...  

Background: Bicuspid aortic valve (BAV) is the most common congenital heart defect and it is responsible for an increased risk of developing aortic valve and ascending aorta complications. In case of mild to moderate BAV disease in patients undergoing supracoronary ascending aorta replacement, it is unclear whether a concomitant aortic valve replacement should be performed. Methods: From June 2002 to January 2020, 75 patients with mild-to-moderate BAV regurgitation (± mild-to-moderate stenosis) who underwent isolated supracoronary ascending aorta replacement were retrospectively analyze. Clinical and echocardiographic follow-up was 100% complete (mean: 7.4±3.9 years, max 16.4). Kaplan Meier estimates were employed to analyze long-term survival. Cumulative incidence function for time to re-operation, recurrence of aortic regurgitation (AR)≥3+ and aortic stenosis (AS) greater than moderate, with death as competing risk, were computed. Results: There was no hospital mortality and no cardiac death occurred. Overall survival at 12 years was 97.4±2.5%, 95% CI [83.16-99.63]. At follow-up there were no cases of aortic root surgery whereas 3 patients underwent AV replacement. At 12 years the CIF of reoperation was 2.6±2.5%, 95% CI [0.20-11.53]. At follow up, AR 3+/4+ was present in 1 pt and AS greater than moderate in 3. At 12 years the CIF of AR>2+/4+ was 5.1±4.98% and of AS>moderate 6.9±3.8%. Conclusions: In our study mild to moderate regurgitation of a BAV did not significantly worse at least up to 10 years after isolated supracoronary ascending aorta replacement.


2013 ◽  
Vol 2013 ◽  
pp. 1-6 ◽  
Author(s):  
Massimiliano Sperandio ◽  
Chiara Arganini ◽  
Alessio Bindi ◽  
Armando Fusco ◽  
Carlo Olevano ◽  
...  

The aim of our study was to compare the results of the TTE (transthoracic echocardiography) with the results obtained by the ECG-gated 64 slices CT during the followup of patients with bicuspid aortic valve (BAV), after aortic valve replacement; in particular we evaluated the aortic root and the ascending aorta looking for a new algorithm in the followup of these patients. From January 1999 to December 2009 our attention was focused on 67 patients with isolated surgical substitution of aortic valve; after dismissal they were strictly observed. During the period between May and September 2010, these patients underwent their last evaluation, and clinical exams, ECG, TTE, and an ECG-gated-MDCT were performed. At followup TTE results showed an aortic root of 36.7±4 mm and an ascending aorta of 39.6±4.8 mm. ECG- gated CT showed an aortic root of 37.9±5.5 mm and an ascending aorta of 43.1±5.2. The comparison between preoperative and postoperative TTE shows a significant long-term dilatation of the ascending aorta while the aortic root diameter seems to be stable. ECG-gated CT confirms the stability of the aortic root diameter (38.2±5.3 mm versus 37.9±5.5  mm; <0.0001) and the increasing diameter value of the ascending aorta (40.2±3.9 mm versus 43.1±5.2 mm; P=0.0156). Due to the different findings between CT and TTE studies, ECG-gated CT should no longer be considered as a complementary exam in the followup of patients with BAV, but as a fundamental role since it is a real necessity.


2017 ◽  
Vol 53 (3) ◽  
pp. 560-568 ◽  
Author(s):  
Tsuyoshi Kaneko ◽  
Prem Shekar ◽  
Vladimir Ivkovic ◽  
Nicholas T Longford ◽  
Chuan-Chin Huang ◽  
...  