Generation and characterization of nano tungsten oxide particles by wire explosion process

2011 ◽  
Vol 62 (2) ◽  
pp. 248-255 ◽  
Author(s):  
S. Aravinth ◽  
Binu Sankar ◽  
S.R. Chakravarthi ◽  
R. Sarathi
2016 ◽  
Vol 5 (3) ◽  
pp. 229-233
Author(s):  
Qiang Wang ◽  
Jigang Wang ◽  
Mingming Sun ◽  
Ming Guo ◽  
Huifeng Li ◽  
...  

2012 ◽  
Vol 38 (7) ◽  
pp. 5507-5512 ◽  
Author(s):  
R. Sugunakar Reddy ◽  
M. Kamaraj ◽  
U. Kamachi Mudali ◽  
S.R. Chakravarthy ◽  
R. Sarathi

2007 ◽  
Vol 30 (2) ◽  
pp. 187-195 ◽  
Author(s):  
T. K. Sindhu ◽  
R. Sarathi ◽  
S. R. Chakravarthy

2017 ◽  
Vol 10 (6) ◽  
pp. 2271-2281 ◽  
Author(s):  
Juha Kangasluoma ◽  
Susanne Hering ◽  
David Picard ◽  
Gregory Lewis ◽  
Joonas Enroth ◽  
...  

Abstract. In this study we characterized the performance of three new particle counters able to detect particles smaller than 3 nm during the Helsinki condensation particle counter (CPC) workshop in summer 2016: the Aerosol Dynamics Inc. (ADI; Berkeley, USA) versatile water condensation particle counter (vWCPC), TSI 3777 nano enhancer (TSI Inc., Shoreview, USA) and modified and boosted TSI 3010-type CPC from Université Blaise Pascal called a B3010. The performance of all CPCs was first measured with charged tungsten oxide test particles at temperature settings which resulted in supersaturation low enough to not detect any ions produced by a radioactive source. Due to similar measured detection efficiencies, additional comparison between the 3777 and vWCPC were conducted using electrically neutral tungsten oxide test particles and with positively charged tetradodecylammonium bromide. Furthermore, the detection efficiencies of the 3777 and vWCPC were measured with boosted temperature settings yielding supersaturation which was at the onset of homogeneous nucleation for the 3777 or confined within the range of liquid water for the ADI vWCPC. Finally, CPC-specific tests were conducted to probe the response of the 3777 to various inlet flow relative humidities, of the B3010 to various inlet flow rates and of the vWCPC to various particle concentrations. For the 3777 and vWCPC the measured 50 % detection diameters (d50s) were in the range of 1.3–2.4 nm for the tungsten oxide particles, depending on the particle charging state and CPC temperature settings, between 2.5 and 3.3 nm for the organic test aerosol, and in the range of 3.2–3.4 nm for tungsten oxide for the B3010.


2017 ◽  
Author(s):  
Juha Kangasluoma ◽  
Susanne Hering ◽  
David Picard ◽  
Gregory Lewis ◽  
Joonas Enroth ◽  
...  

Abstract. The scientific need to understand nanoparticle dynamics at sizes below 3 nm has pushed companies to develop commercial solutions to measure particles down to 1 nm. In this study we characterize the performance of three new particle counters able to detect particles smaller than 3 nm: Aerosol Dynamics Inc versatile water condensation particle counter (v-WCPC, ADI, Berkeley, USA), TSI 3777 nano enhancer (TSI Inc., Shoreview, USA) and modified and boosted 3010 type CPC from Clermont Ferrand University called as B3010. The 3777 and v-WCPC were characterized using tungsten oxide test particles with all charging states: negative, positive and neutral, and with positively charged tetradodecylammonium bromide. The detection efficiencies of the particle counters were measured with two different temperature settings: low temperature difference settings so that the CPCs did not detect any ions from a radioactive source; and high temperature difference settings so that the supersaturation was at the onset of homogeneous nucleation for the 3777, or confined within the range of liquid water for the ADI v-WCPC. The measured 50 % detection diameters (d50) were in the range of 1.3–2.4 nm for the tungsten oxide particles depending on the particle charging state and CPC temperature settings, and between 2.5 and 3.3 nm for the organic test aerosol for the 3777 and v-WCPC. The d50s were measured for the B3010 with negatively charged tungsten oxide particles with four different inlet flow rates. The v-WCPC and 3777 were also compared side by side by measuring atmospheric aerosol, exhibiting an excellent agreement.


2009 ◽  
Vol 475 (1-2) ◽  
pp. 658-663 ◽  
Author(s):  
R. Sarathi ◽  
T.K. Sindhu ◽  
S.R. Chakravarthy ◽  
Archana Sharma ◽  
K.V. Nagesh

2012 ◽  
Vol 53 (8) ◽  
pp. 1420-1424 ◽  
Author(s):  
R. Sugunakar Reddy ◽  
M. Kamaraj ◽  
U. Kamachi Mudali ◽  
S. R. Chakravarthy ◽  
R. Sarathi

2010 ◽  
Vol 496 (1-2) ◽  
pp. 122-128 ◽  
Author(s):  
B. Debalina ◽  
M. Kamaraj ◽  
B.S. Murthy ◽  
S.R. Chakravarthi ◽  
R. Sarathi

2015 ◽  
Vol 648 ◽  
pp. 297-306 ◽  
Author(s):  
Tzu Hsuan Chiang ◽  
Chia-Chun Hsu ◽  
Tso-Ming Chen ◽  
Bing-Sheng Yu

Sign in / Sign up

Export Citation Format

Share Document