Spatial calibration via imaging techniques of a novel scanning system for the pulse shape characterisation of position sensitive HPGe detectors

Author(s):  
N. Goel ◽  
C. Domingo-Pardo ◽  
T. Engert ◽  
J. Gerl ◽  
I. Kojouharov ◽  
...  
2021 ◽  
Vol 253 ◽  
pp. 11009
Author(s):  
Arzoo Sharma ◽  
R. Palit ◽  
I. Kojouharov ◽  
J. Gerl ◽  
M. Gorska-Ott ◽  
...  

This work presents the results from the characterization of a Position-Sensitive Planar Germanium (PSPGe) detector. The PSPGe detector is a double-sided orthogonal strip detector consisting of 10x10 electrical segmentation along the horizontal and vertical directions. The characterization was performed using the coincidence setup between the PSPGe detector and the well-characterized scanning system employing the positron annihilation correlation principle. The scanning system consists of a Position Sensitive Detector (PSD) and 22Na positron source. The main objective of this study is to deploy PSPGe detector for future decay experiments at the Facility for Antiproton and Ion Research (FAIR), Germany. The measurements have been performed to find the depth of gamma-ray interaction in the planar segmented detector. The 2-Dimensional image obtained from the PSD has been used to find the depth of gamma-ray interaction in the planar strip detector using pulse shape analysis. In addition, the sensitivity of PSPGe detector has been investigated by calculating the rise-time from pulse shapes for the front and back strips of the detector.


Author(s):  
F.C.L. Crespi ◽  
V. Vandone ◽  
S. Brambilla ◽  
F. Camera ◽  
B. Million ◽  
...  

2000 ◽  
Vol 33 (5) ◽  
pp. 1253-1261 ◽  
Author(s):  
Y. T. Cheng ◽  
D. F. R. Mildner ◽  
H. H. Chen-Mayer ◽  
V. A. Sharov ◽  
C. J. Glinka

Small-angle neutron scattering (SANS) measurements have been performed on long-flight-path pinhole-collimation SANS instruments using, as a two-dimensional position-sensitive detector, both a neutron imaging plate, incorporating gadolinium, and a two-step transfer method, with dysprosium foil as the image transfer medium. The measurements are compared with corresponding data taken using conventional position-sensitive gas proportional counters on the SANS instruments in order to assess the viability of the imaging techniques. The imaging plates have pixel sizes of about two orders of magnitude smaller than those of the gas proportional counter. The reduced pixel size provides definite advantages over the gas counter in certain specific situations, namely when limited space necessitates a short sample-to-detector distance, when only small samples (comparable in size to the detector pixels) are available, or when used in conjunction with focusing beam optics.


2014 ◽  
Vol 59 ◽  
pp. 119-124 ◽  
Author(s):  
P. Reiter ◽  
B. Birkenbach ◽  
T. Kotthaus