A retrospective review of Naso-jejunal tube placement comparing endoscopically-placed versus radiologically-placed tubes; do those placed with imaging at the time of insertion last longer?

Nutrition ◽  
2008 ◽  
Vol 24 (5) ◽  
pp. 497
Author(s):  
M. McCarthy ◽  
A. Ansari ◽  
A. de Jabrun ◽  
M. Small ◽  
R. Salter ◽  
...  
Critical Care ◽  
2021 ◽  
Vol 25 (1) ◽  
Author(s):  
Patrick M. Honore ◽  
Sebastien Redant ◽  
Thierry Preseau ◽  
Sofie Moorthamers ◽  
Keitiane Kaefer ◽  
...  

2002 ◽  
Vol 126 (6) ◽  
pp. 653-656 ◽  
Author(s):  
Soo H. Kim ◽  
James J. Kearney ◽  
Joseph P. Atkins

OBJECTIVE: Our goal was to determine whether percutaneous laryngeal collagen augmentation improves hypophonia in parkinsonian patients. STUDY DESIGN AND SETTING: A retrospective review of 18 patients was performed. Patients and/or caretakers were called on the telephone and asked about their response to the procedure, if any. Videostroboscopic examinations for all patients were reviewed. RESULTS: Of 18 patients, 11 (61%) reported improvement in their hypophonia for a period of at least 2 months. Five of 7 patients without improvement were relatively aphonic both before and after the procedure. Five of 7 patients without improvement had severe dysphagia, which in 3 necessitated gastrostomy tube placement. Four of 7 patients without improvement were not ambulatory at the time of the procedure. CONCLUSIONS: Percutaneous laryngeal collagen augmentation is an effective treatment for parkinsonian hypophonia in a majority of patients. Patients with advanced neurologic disease with aphonia, difficulty with speech initiation, dysphagia, or ambulatory difficulty are less likely to respond to this procedure and should be so informed.


2021 ◽  
Vol 4 (Supplement_1) ◽  
pp. 30-31
Author(s):  
O Akman ◽  
D Duerksen

Abstract Background Continuous intestinal infusion of levodopa/carbidopa intestinal gel (LCIG) for the treatment of advanced Parkinson’s Disease (PD) leads to less variability in plasma drug levels and improved symptom control. Percutaneous Gastrojejunostomy (PEG-J) tube placement has a high placement success rate; however, delayed tube malfunctions occur in approximately 58% of cases within two years. A rare complication is bezoar formation at the jejunal tube tip. Aims To present a case of bezoar formation at the jejunal tip of a PEG-J tube that caused distal migration of the tube with gastroduodenal ulceration and required surgical extraction. Methods Full chart review was conducted including clinical notes, laboratory results, radiographic imaging, endoscopy reports, and surgical reports. A relevant literature review was conducted. Results A 57-year-old male with severe PD underwent endoscopic guided PEG-J tube insertion for continuous infusion of LCIG; intestinal administration was effective for symptom control. Two years later, he noted that the gastric tube had retracted approximately 15 cm into the stoma without external manipulation of the apparatus. Attempts to externally pull the tube back into position were unsuccessful. The patient underwent Gastroscopy (EGD) with fluoroscopy. Contrast was used to confirm placement of the jejunal tip within the jejunum, but also showed migration of the gastric tip into the duodenum. A gastroscope was used to reposition the gastric tube in the stomach; the jejunal tube was visualized to be under traction. The bumper on the apparatus was re-positioned and external tape was used to further secure the apparatus and prevent migration. A month later the tube had migrated again; repeat EGD showed the jejunal tube to be under traction with some resultant ulceration of the pyloric channel and duodenal bulb where the tube had been pressing against the mucosa. The jejunal tube could not be pulled back and appeared to be fixed distally. A CT scan was obtained to assess for complications and a coiled tip was seen in the proximal jejunum. Surgical extraction of the malfunctioning tube was required. At laparotomy, the coiled tip of the feeding tube was successfully removed via enterotomy. The tube tip had coiled around itself and was encased with food materials, creating a large bezoar that was being pulled distally by peristalsis. The patient subsequently underwent insertion of a new GJ tube for ongoing administration of LCIG and has been doing well since. Conclusions Bezoar formation at the jejunal tip of LCIG PEG-J tubes is a rare complication and can lead to distal migration and traction related gastroduodenal ulceration. Surgical removal may be required. Funding Agencies None


Author(s):  
Yasushi Iinuma ◽  
Yutaka Hirayama ◽  
Kengo Nakaya ◽  
Yu Sugai ◽  
hotaro Taki ◽  
...  

2014 ◽  
Vol 25 (1) ◽  
pp. 55-63 ◽  
Author(s):  
Fàtima Sabench Pereferrer ◽  
Margarida Vives Espelta ◽  
Arantxa Cabrera Vilanova ◽  
Mercè Hernández González ◽  
Albert Feliu Rovira ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document