Evaluation of various head flexion angles in hippocampal-avoidance whole-brain radiotherapy using volumetric modulated arc therapy

2020 ◽  
Vol 173 ◽  
pp. 108884 ◽  
Author(s):  
Y.F. Lin ◽  
P.H. Chen ◽  
P.W. Shueng ◽  
H.H. Lin ◽  
L.H. Lai
2019 ◽  
Vol 1 (Supplement_1) ◽  
pp. i26-i27
Author(s):  
Diana Julie ◽  
Sean Mahase ◽  
Diana No ◽  
Khaled Salah ◽  
Jonathan Knisely

Abstract OBJECTIVE: Whole brain radiotherapy (WBRT) causes neurocognitive decline. Hippocampal avoidance WBRT (HA-WBRT) reduces hippocampal irradiation, potentially mitigating neurocognitive sequelae. We compared hippocampal and brain dosimetry with HA-WBRT with 6 megavoltage (MV) versus 10 MV photon energies. METHODS: Twenty consecutive patients treated with WBRT were retrospectively replanned with HA-WBRT techniques using 6 MV and 10 MV photons. Coplanar volumetric modulated arc therapy was employed, with a prescription dose of 3000 cGy in 10 fractions. Planning was done with Eclipse version 13.6 or 15.6. Nine patients were planned with 2.5 mm multileaf collimator leaves, with the remainder planned with 5 mm leaves. The hippocampi were contoured and a HA structure was generated using a uniform 5 mm expansion. A planning target volume (PTV) was defined as the brain parenchyma minus the HA structure. NRG-CC001 dose constraints were used. For each variable, descriptive statistics were calculated. Comparisons were made using two-tailed Wilcoxon signed rank tests or paired t-tests. RESULTS: The minimum hippocampal dose (D100%) was improved with 6 MV plans, 841 cGy compared to 914 cGy with 10 MV (p< 0.005). The maximum hippocampal dose (D0.03cc) was reduced with 6 MV planning, 1614 cGy versus 1676 cGy for 10 MV (p< 0.0001). With 6 MV photons, a greater number of plans met NRG-CC001 constraints without deviations. 6 MV photons improved PTV coverage by the 95% isodose line, 96.6% compared to 95.9% for 10 MV (p=0.021). 6 MV photon plans decreased the volume of PTV receiving ≥105% of the prescription, 84.2% versus 87.9% for 10 MV (p=0.006). The mean dose, hot spots, and cold spots did not differ by photon energy. PTV dose constraints were always met. CONCLUSION: 6 MV photon HA-WBRT plans are dosimetrically superior to 10 MV, reducing hippocampal radiation dose, without compromise in brain coverage and improved target dose homogeneity.


2017 ◽  
Vol 64 (8) ◽  
pp. e26434 ◽  
Author(s):  
Atsushi Iwai ◽  
Katsutsugu Umeda ◽  
Megumi Uto ◽  
Hiroshi Nihira ◽  
Koji Kawaguchi ◽  
...  

2012 ◽  
Vol 103 ◽  
pp. S482-S483
Author(s):  
D. Russo ◽  
A. Paladini ◽  
C.D. Gianfreda ◽  
C. Accettura ◽  
C. Capomolla ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document