On measuring the 3D dose distribution for notched and circular Ru-106 plaque shapes through Gafchromic film dosimetry approach

2022 ◽  
Vol 190 ◽  
pp. 109792
Author(s):  
Taha Eidi ◽  
Seyed Mahmoud Reza Aghamiri ◽  
Ramin Jaberi ◽  
Hamid Reza Baghani
2019 ◽  
Vol 121 ◽  
pp. 69-76 ◽  
Author(s):  
Somayeh Gholami ◽  
Hassan Ali Nedaie ◽  
Ali S. Meigooni

2018 ◽  
Vol 45 (5) ◽  
pp. 2329-2336 ◽  
Author(s):  
Neda Gholizadeh Sendani ◽  
Alireza Karimian ◽  
Clara Ferreira ◽  
Parham Alaei

2004 ◽  
Vol 31 (5) ◽  
pp. 1243-1248 ◽  
Author(s):  
M. Yamauchi ◽  
T. Tominaga ◽  
O. Nakamura ◽  
R. Ueda ◽  
M. Hoshi

2017 ◽  
Vol 51 (4) ◽  
pp. 469-474 ◽  
Author(s):  
Grzegorz Zwierzchowski ◽  
Grzegorz Bieleda ◽  
Janusz Skowronek

Abstract Background Fast and easily repeatable methods for commissioning procedures for brachytherapy (BT) treatment planning systems (TPS) are needed. Radiochromic film dosimetry with gamma analysis is widely used in external beam quality assurance (QA) procedures and planar film dosimetry is also increasingly used for verification of the dose distribution in BT applications. Using the gamma analysis method for comparing calculated and measured dose data could be used for commissioning procedures of the newly developed TG-186 and MBDCA calculation algorithms. The aim of this study was dosimetric verification of the calculation algorithm used in TPS when the CT/MRI ring applicator is used. Materials and methods Ring applicators with 26 and 30 mm diameters and a 60 mm intra-uterine tube with 60° angle were used for verification. Gafchromic® EBT films were used as dosimetric media. Dose grids, corresponding to each plane (dosimetric film location), were exported from the TPS as a raw data. Gafchromic® films were digitized after irradiation. gamma analysis of the data were performed using the OMNI Pro I’mRT® system, as recommended by the AAPM TG-119 rapport criterion for gamma analysis of 3%, 3 mm and a level of 95%. Results For the 26 mm and 30 mm rings, the average gamma ranged, respectively, from 0.1 to 0.44 and from 0.1 to 0.27. In both cases, 99% of the measured points corresponded with the calculated data. Conclusions This analysis showed excellent agreement between the dose distribution calculated with the TPS and the doses measured by Gafchromic films. This finding confirms the viability of using film dosimetry in BT.


2015 ◽  
Vol 16 (6) ◽  
pp. 325-332 ◽  
Author(s):  
Meral L. Reyhan ◽  
Ting Chen ◽  
Miao Zhang

Sign in / Sign up

Export Citation Format

Share Document