A comparison of the I-gel supraglottic airway as a conduit for tracheal intubation with the intubating laryngeal mask airway: A manikin study

Resuscitation ◽  
2010 ◽  
Vol 81 (1) ◽  
pp. 74-77 ◽  
Author(s):  
P. Michalek ◽  
W. Donaldson ◽  
C. Graham ◽  
J.D. Hinds
2016 ◽  
Vol 10 (1) ◽  
pp. 18-24
Author(s):  
Bharat Choudhary ◽  
Rakesh Karnawat ◽  
Sadik Mohammed ◽  
Monika Gupta ◽  
Bharath Srinivasan ◽  
...  

Background: Supraglottic airway devices (SADs) are very useful airway adjunct in managing anticipated and unanticipated difficult airway and can be used as a ventilating aid and as a conduit for tracheal intubation. The new versions of SADs like i-gel and intubating laryngeal mask airway (ILMA), have advantage of hands-free airway maintenance without the need for tracheal intubation, they can be placed easily without direct visualization of the larynx, ensure predictable ventilation and can be used as conduit for tracheal intubation. Objective: To compare ease and success of placement of both SADs and ease and success of endotracheal (ET) intubation through both SADs. Method: Eighty patients of both sexes, aged between 18-60 years and belonging to ASA grade I and II undergoing surgical procedure under general anaesthesia (GA) were randomly divided into two group (i-gel and ILMA) of equal number. Following induction the allocated device was inserted and after confirming adequate ventilation, blind ET intubation was attempted through the device. First attempt and overall success rate of SAD insertion and ET intubation through SAD; time taken for SAD insertion and ET intubation through SAD; hemodynamic changes and postoperative complications were recorded and compared between groups. Result: Demographic profile, success rate of SAD insertion, haemodynamic changes and adverse effects were similar between groups (p>0.05).Overall time needed for successful SAD insertion was significantly shorter in group i-gel (22.52±5.64 sec) than group ILMA (31.15±5.52 sec) (p value <0.0001). Overall success rate of blind ET intubation was higher in group i-gel (75%) in comparison to group ILMA (65%). I-gel required significantly less time to achieve successful ET intubation than ILMA (26.30±11.35 sec vs. 33.53±13.13 sec)(p<0.0001). Conclusion: Both the SADs were proved to be useful alternative to conventional laryngoscope for ET intubation, although i-gel required lesser time and had better success rate of ET intubation as compared to ILMA.


2016 ◽  
Vol 117 (4) ◽  
pp. 164-175 ◽  
Author(s):  
Pavel Michálek ◽  
Will Donaldson ◽  
Francis McAleavey ◽  
Alexander Abraham ◽  
Rachel J. Mathers ◽  
...  

Fibreoptic intubation through a supraglottic airway is an alternative plan for airway management in difficult or failed laryngoscopy. The aim of this study was to compare three supraglottic airways as conduits in patients with at least one predictor for difficult laryngoscopy. The i-gel was compared with the single-use intubating laryngeal mask airway (sILMA) and CTrach laryngeal mask in 120 adult patients scheduled for elective surgeries under general anaesthesia using a prospective, randomized and single-blinded design. Primary outcome was success rate of tracheal intubation through the device, while secondary outcomes were times required for device insertion and tracheal tube placement, fibreoptic scores and the incidence of perioperative complications and postoperative complaints. The success rates showed no statistical difference between devices (i-gel 100%, CTrach 97.5%, ILMA 95%). Insertion time was shortest for the i-gel (12.4 s) compared with ILMA (19.3 s) and CTrach (24.4 s). Intubation time was shorter in the i-gel group (29.4 s) in comparison with the CTrach (39.8 s, p<0.05) and sILMA (51.9 s, p<0.001) groups. Best fibreoptic scores were observed also in the i-gel group. In total, 24 patients (20%) presented with difficult laryngoscopy. The i-gel showed significantly shorter times for insertion and fibreoptic intubation than the other two devices in this group. No difference was observed in the incidence of postoperative complaints. The i-gel is a suitable alternative to the sILMA and CTrach for fibrescope-guided tracheal intubation. Shorter insertion and intubation times with the i-gel may provide advantage in case of difficult oxygenation.


2001 ◽  
Vol 94 (6) ◽  
pp. 968-972 ◽  
Author(s):  
Olivier Langeron ◽  
François Semjen ◽  
Jean-Louis Bourgain ◽  
Alain Marsac ◽  
Anne-Marie Cros

Background The intubating laryngeal mask airway (ILMA; Fastrach; Laryngeal Mask Company, Henley-on-Thames, UK) may provide an alternative technique to fiberoptic intubation (FIB) to facilitate the management of the anticipated difficult airway. The authors therefore compared the effectiveness of the ILMA with FIB in patients with anticipated difficult intubation. Methods One hundred patients, with at least one difficult intubation criteria (Mallampati class III or IV, thyromental distance &lt; 65 mm, interincisor distance &lt; 35 mm) were enrolled (FIB group, n = 49; ILMA group, n = 51) in this prospective randomized study. Anesthesia was induced with propofol and maintained with alfentanil and propofol after an efficient mask ventilation has been demonstrated. The success of the technique (within three attempts), the number of attempts, duration of the successful attempt, and adverse events (oxygen saturation &lt; 90%, bleeding) were recorded. Results The rate of successful tracheal intubation with ILMA was 94% and comparable with FIB (92%). The number of attempts and the time to succeed were not significantly different between groups. In case of failure of the first technique, the alternative technique always succeeded. Failures in FIB group were related to oxygen desaturation (oxygen saturation &lt; 90%) and bleeding, and to previous cervical radiotherapy in the ILMA group. Adverse events occurred significantly more frequently in FIB group than in ILMA group (18 vs. 0%, P &lt; 0.05). Conclusion The authors obtained a high success rate and comparable duration of tracheal intubation with ILMA and FIB techniques. In patients with previous cervical radiotherapy, the use of ILMA cannot be recommended. Nevertheless, the use of the ILMA was associated with fewer adverse events.


2016 ◽  
Vol 46 ◽  
pp. 1617-1623 ◽  
Author(s):  
Semih ÖZDİL ◽  
Zehra İpek ARSLAN AYDIN ◽  
Zehra Nur BAYKARA ◽  
Kamil TOKER ◽  
Zeynep Mine SOLAK

Sign in / Sign up

Export Citation Format

Share Document