scholarly journals Perception modelling by invariant representation of deep learning for automated structural diagnostic in aircraft maintenance: A study case using DeepSHM

Author(s):  
Vincentius Ewald ◽  
Ramanan Sridaran Venkat ◽  
Aadhik Asokkumar ◽  
Rinze Benedictus ◽  
Christian Boller ◽  
...  
2021 ◽  
Author(s):  
Ziwei Xie ◽  
Jinbo Xu

Motivation: Inter-protein (interfacial) contact prediction is very useful for in silico structural characterization of protein-protein interactions. Although deep learning has been applied to this problem, its accuracy is not as good as intra-protein contact prediction. Results: We propose a new deep learning method GLINTER (Graph Learning of INTER-protein contacts) for interfacial contact prediction of dimers, leveraging a rotational invariant representation of protein tertiary structures and a pretrained language model of multiple sequence alignments (MSAs). Tested on the 13th and 14th CASP-CAPRI datasets, the average top L/10 precision achieved by GLINTER is 54.35% on the homodimers and 51.56% on all the dimers, much higher than 30.43% obtained by the latest deep learning method DeepHomo on the homodimers and 14.69% obtained by BIPSPI on all the dimers. Our experiments show that GLINTER-predicted contacts help improve selection of docking decoys.


2020 ◽  
Vol 10 (1) ◽  
Author(s):  
Kyung-Ok Cho ◽  
Hyun-Jong Jang

AbstractThe manual review of an electroencephalogram (EEG) for seizure detection is a laborious and error-prone process. Thus, automated seizure detection based on machine learning has been studied for decades. Recently, deep learning has been adopted in order to avoid manual feature extraction and selection. In the present study, we systematically compared the performance of different combinations of input modalities and network structures on a fixed window size and dataset to ascertain an optimal combination of input modalities and network structures. The raw time-series EEG, periodogram of the EEG, 2D images of short-time Fourier transform results, and 2D images of raw EEG waveforms were obtained from 5-s segments of intracranial EEGs recorded from a mouse model of epilepsy. A fully connected neural network (FCNN), recurrent neural network (RNN), and convolutional neural network (CNN) were implemented to classify the various inputs. The classification results for the test dataset showed that CNN performed better than FCNN and RNN, with the area under the curve (AUC) for the receiver operating characteristics curves ranging from 0.983 to 0.984, from 0.985 to 0.989, and from 0.989 to 0.993 for FCNN, RNN, and CNN, respectively. As for input modalities, 2D images of raw EEG waveforms yielded the best result with an AUC of 0.993. Thus, CNN can be the most suitable network structure for automated seizure detection when applied to the images of raw EEG waveforms, since CNN can effectively learn a general spatially-invariant representation of seizure patterns in 2D representations of raw EEG.


Author(s):  
Stellan Ohlsson
Keyword(s):  

1962 ◽  
Vol 41 (9) ◽  
pp. 522
Author(s):  
E. Mill ◽  
E.W.de W. Waller ◽  
R.E.W. Harland ◽  
A.F. Kelley ◽  
Fairy Vines ◽  
...  
Keyword(s):  

2019 ◽  
Vol 53 (3) ◽  
pp. 281-294
Author(s):  
Jean-Michel Foucart ◽  
Augustin Chavanne ◽  
Jérôme Bourriau

Nombreux sont les apports envisagés de l’Intelligence Artificielle (IA) en médecine. En orthodontie, plusieurs solutions automatisées sont disponibles depuis quelques années en imagerie par rayons X (analyse céphalométrique automatisée, analyse automatisée des voies aériennes) ou depuis quelques mois (analyse automatique des modèles numériques, set-up automatisé; CS Model +, Carestream Dental™). L’objectif de cette étude, en deux parties, est d’évaluer la fiabilité de l’analyse automatisée des modèles tant au niveau de leur numérisation que de leur segmentation. La comparaison des résultats d’analyse des modèles obtenus automatiquement et par l’intermédiaire de plusieurs orthodontistes démontre la fiabilité de l’analyse automatique; l’erreur de mesure oscillant, in fine, entre 0,08 et 1,04 mm, ce qui est non significatif et comparable avec les erreurs de mesures inter-observateurs rapportées dans la littérature. Ces résultats ouvrent ainsi de nouvelles perspectives quand à l’apport de l’IA en Orthodontie qui, basée sur le deep learning et le big data, devrait permettre, à moyen terme, d’évoluer vers une orthodontie plus préventive et plus prédictive.


2020 ◽  
Author(s):  
L Pennig ◽  
L Lourenco Caldeira ◽  
C Hoyer ◽  
L Görtz ◽  
R Shahzad ◽  
...  
Keyword(s):  

Sign in / Sign up

Export Citation Format

Share Document