T1801 A New Method for the High-Resolution Mapping of Human Slow Wave Activity Using Flexible Printed Circuit Board Electrodes

2009 ◽  
Vol 136 (5) ◽  
pp. A-583
Author(s):  
Peng Du ◽  
Gregory O'Grady ◽  
John U. Egbuji ◽  
Wim Lammers ◽  
John A. Windsor ◽  
...  
2016 ◽  
Vol 150 (4) ◽  
pp. S721
Author(s):  
Timothy R. Angeli ◽  
Niranchan Paskaranandavadivel ◽  
Peng Du ◽  
Samuel J. Asirvatham ◽  
Gianrico Farrugia ◽  
...  

2009 ◽  
Vol 136 (5) ◽  
pp. A-579-A-580
Author(s):  
Gregory O'Grady ◽  
Peng Du ◽  
John U. Egbuji ◽  
Wim Lammers ◽  
Leo K. Cheng ◽  
...  

2015 ◽  
Vol 148 (4) ◽  
pp. S-506
Author(s):  
Timothy R. Angeli ◽  
Peng Du ◽  
David J. Midgley ◽  
Niranchan Paskaranandavadivel ◽  
Christopher J. Lahr ◽  
...  

2015 ◽  
Vol 148 (4) ◽  
pp. S-535
Author(s):  
Rachel Berry ◽  
Niranchan Paskaranandavadivel ◽  
Peng Du ◽  
Timothy R. Angeli ◽  
Ryash Vather ◽  
...  

2010 ◽  
Vol 138 (5) ◽  
pp. S-314
Author(s):  
John U. Egbuji ◽  
Gregory O'Grady ◽  
Peng Du ◽  
Leo K. Cheng ◽  
Wim Lammers ◽  
...  

2010 ◽  
Vol 299 (3) ◽  
pp. G585-G592 ◽  
Author(s):  
Gregory O'Grady ◽  
Peng Du ◽  
Leo K. Cheng ◽  
John U. Egbuji ◽  
Wim J. E. P. Lammers ◽  
...  

Slow waves coordinate gastric motility, and abnormal slow-wave activity is thought to contribute to motility disorders. The current understanding of normal human gastric slow-wave activity is based on extrapolation from data derived from sparse electrode recordings and is therefore potentially incomplete. This study employed high-resolution (HR) mapping to reevaluate human gastric slow-wave activity. HR mapping was performed in 12 patients with normal stomachs undergoing upper abdominal surgery, using flexible printed circuit board (PCB) arrays (interelectrode distance 7.6 mm). Up to six PCBs (192 electrodes; 93 cm2) were used simultaneously. Slow-wave activity was characterized by spatiotemporal mapping, and regional frequencies, amplitudes, and velocities were defined and compared. Slow-wave activity in the pacemaker region (mid to upper corpus, greater curvature) was of greater amplitude (mean 0.57 mV) and higher velocity (8.0 mm/s) than the corpus (0.25 mV, 3.0 mm/s) ( P < 0.001) and displayed isotropic propagation. A marked transition to higher amplitude and velocity activity occurred in the antrum (0.52 mV, 5.9 mm/s) ( P < 0.001). Multiple (3–4) wavefronts were found to propagate simultaneously in the organoaxial direction. Frequencies were consistent between regions (2.83 ± 0.35 cycles per min). HR mapping has provided a more complete understanding of normal human gastric slow-wave activity. The pacemaker region is associated with high-amplitude, high-velocity activity, and multiple wavefronts propagate simultaneously. These data provide a baseline for future HR mapping studies in disease states and will inform noninvasive diagnostic strategies.


Sign in / Sign up

Export Citation Format

Share Document