scholarly journals Successful treatment of aortic valve endocarditis and aortic root abscesses by insertion of prosthetic valve in ascending aorta and placement of bypass grafts to coronary arteries

1974 ◽  
Vol 67 (3) ◽  
pp. 443-449 ◽  
Author(s):  
Gordon K. Danielson ◽  
Jack L. Titus ◽  
James W. DuShane
2019 ◽  
Vol 22 (5) ◽  
pp. E380-E384 ◽  
Author(s):  
Tao Li ◽  
Xianhao Bao ◽  
Jiaxuan Feng ◽  
Zhenjiang Li ◽  
Junjun Liu ◽  
...  

Objective: To explore the feasibility of endovascular reconstruction of aortic root including aortic valve, sinus of valsalva and ascending aorta by a single stent-graft, a novel valved stent-graft with two fenestrae for preserving the coronary arteries was designed and performed in-vitro on a pig heart based circulation simulating system. Methods: Pig hearts were harvested from 30 healthy adult female pigs weighing between 60-65 kilograms. Before sacrifice, all the pigs received aortic computed tomography angiography (CTA) examinations and morphologic parameters of aortic root were measured. Then we customized the valved stent-grafts according to the CTA measurements. After the pig heart was fixed on the special platform according to the original orientation and connected to the circulation system, the stent graft was delivered through transapical access and covered the segment from aortic annulus to proximal part of aortic arch under DSA (digital subtraction angiography) guidance. Then changes of coronary flow before and after the procedure and fenestration alignment with coronary ostia were analyzed. Results: The overall technical success rate was 100%. The valve functions tested by ultrasound were in good condition under 120 mmHg circulation pressure. The flow of left coronary artery (LCA) did not decrease, but increased after the stent-graft implantation (340 ± 2.06 mL/min versus 288 ± 5.29 mL/min, P < .05). Similarly, the flow of right coronary artery (RCA) also increased (392 ± 9.17 mL/min versus 348 ± 8.01 mL/min; P < .05). The final angiography confirmed that both coronary arteries were patent. When generally observed from outer wall of valsalva sinus, both RCA and LCA orifices were aligned with the fenestrae. In 4 cases, the autologous valve leaflets blocked nearly 20% of the LCA fenestra’s area, but the flow did not significantly decrease in these cases. Conclusion: Stimulated on a pig heart-based circulation simulation system, the one-piece valved-fenestrated stent graft with a branch could be delivered via the transapical access and deployed accurately, which achieved endovascular reconstruction of aortic valve, sinus of valsalva and ascending aorta while preserving the coronary artery perfusion by fenestrations. More in-vivo experiments on animal models are mandatory to further verify its efficacy and safety.


VASA ◽  
2005 ◽  
Vol 34 (3) ◽  
pp. 181-185 ◽  
Author(s):  
Westhoff-Bleck ◽  
Meyer ◽  
Lotz ◽  
Tutarel ◽  
Weiss ◽  
...  

Background: The presence of a bicuspid aortic valve (BAV) might be associated with a progressive dilatation of the aortic root and ascending aorta. However, involvement of the aortic arch and descending aorta has not yet been elucidated. Patients and methods: Magnetic resonance angiography (MRA) was used to assess the diameter of the ascending aorta, aortic arch, and descending aorta in 28 patients with bicuspid aortic valves (mean age 30 ± 9 years). Results: Patients with BAV, but without significant aortic stenosis or regurgitation (n = 10, mean age 27 ± 8 years, n.s. versus control) were compared with controls (n = 13, mean age 33 ± 10 years). In the BAV-patients, aortic root diameter was 35.1 ± 4.9 mm versus 28.9 ± 4.8 mm in the control group (p < 0.01). The diameter of the ascending aorta was also significantly increased at the level of the pulmonary artery (35.5 ± 5.6 mm versus 27.0 ± 4.8 mm, p < 0.001). BAV-patients with moderate or severe aortic regurgitation (n = 18, mean age 32 ± 9 years, n.s. versus control) had a significant dilatation of the aortic root, ascending aorta at the level of the pulmonary artery (41.7 ± 4.8 mm versus 27.0 ± 4.8 mm in control patients, p < 0.001) and, furthermore, significantly increased diameters of the aortic arch (27.1 ± 5.6 mm versus 21.5 ± 1.8 mm, p < 0.01) and descending aorta (21.8 ± 5.6 mm versus 17.0 ± 5.6 mm, p < 0.01). Conclusions: The whole thoracic aorta is abnormally dilated in patients with BAV, particularly in patients with moderate/severe aortic regurgitation. The maximum dilatation occurs in the ascending aorta at the level of the pulmonary artery. Thus, we suggest evaluation of the entire thoracic aorta in patients with BAV.


Circulation ◽  
2014 ◽  
Vol 130 (suppl_2) ◽  
Author(s):  
Koichi Maeda ◽  
Toru Kuratani ◽  
Kei Torikai ◽  
Isamu Mizote ◽  
Yasuhiro Ichibori ◽  
...  

Introduction: Surgical aortic valve replacement (SAVR) in a small aortic root is still challenging with regard to the surgical technique and prosthesis size selection, which often causes patient-prosthesis mismatch (PPM). On the other hand, because a prosthetic valve of transcatheter aortic valve replacement (TAVR) is tightly implanted inside a native valve, larger effective orifice area (EOA) may be gained. The aim of this study is to prove that hemodynamic performance after TAVR is superior to that after SAVR. Methods: 160 patients, who underwent SAVR (n=36; age 75.1±5.6 years) and TAVR (n=124; age 82.4±6.8 years) for aortic valve stenosis, were enrolled. Preoperative ECG-gated multi-slice CT (MSCT) and echocardiography immediately before a discharge were performed in all patients. PPM was defined as the effective orifice area index ≤0.85cm2/m2 and we compared and examined hemodynamic performance after TAVR and SAVR. Results: Although the mean body size was significantly smaller (p<.05) in TAVR than that in SAVR (1.44±0.15 vs 1.51±0.20 m2), there were no significant differences in the diameters of annulus (23.2±1.6 vs 23.3±2.8 mm), valsalva sinus (29.8±2.6 vs 29.9±4.4 mm), and ST junction (25.2±2.8 vs 24.8±3.5 mm) on preoperative MSCT findings. Postoperative echocardiography revealed significantly less Vmax (2.2±0.4 vs 2.5±0.5 m/s, p<.0001), less mean pressure gradient (10.1±3.6 vs 14.5±5.0 mmHg, p<.0001), and larger EOA (1.62±0.29 vs 1.45±0.36 cm2, p<.005) in TAVR compared to SAVR, respectively. Consequently, PPM was more frequently in SAVR compared to TAVR (33.3 vs 8.9%; p<.0007). In multivariate analysis in SAVR identified small ST junction with only predictive factor of PPM (odds ratio [OR], 2.08; 95% CI, 1.23-4.36; p<.005; area under the receiver-operating characteristic curve [AUC], 0.84). On the other hand, regarding TAVR, large BSA was only predictive factor of PPM (p<.05). Conclusions: The hemodynamic performance of transcatheter prosthetic valve is superior to that of surgical prosthetic valve in a patient with small aortic root, in particular, small ST junction. TAVR should be considered in patients with anticipated PPM if the surgical risk is similar to TAVR.


2019 ◽  
Vol 10 (5) ◽  
pp. 624-627
Author(s):  
Jeremy L. Herrmann ◽  
Amanda R. Stram ◽  
John W. Brown

Prosthesis choice for aortic valve replacement (AVR) in children is frequently compromised by unavailability of prostheses in very small sizes, the lack of prosthetic valve growth, and risks associated with long-term anticoagulation. The Ross procedure with pulmonary valve autograft offers several advantages for pediatric and adult patients. We describe our current Ross AVR technique including replacement of the ascending aorta with a prosthetic graft. The procedure shown in the video involves an adult-sized male with a bicuspid aortic valve, mixed aortic stenosis and insufficiency, and a dilated ascending aorta.


2013 ◽  
Vol 2013 ◽  
pp. 1-6 ◽  
Author(s):  
Massimiliano Sperandio ◽  
Chiara Arganini ◽  
Alessio Bindi ◽  
Armando Fusco ◽  
Carlo Olevano ◽  
...  

The aim of our study was to compare the results of the TTE (transthoracic echocardiography) with the results obtained by the ECG-gated 64 slices CT during the followup of patients with bicuspid aortic valve (BAV), after aortic valve replacement; in particular we evaluated the aortic root and the ascending aorta looking for a new algorithm in the followup of these patients. From January 1999 to December 2009 our attention was focused on 67 patients with isolated surgical substitution of aortic valve; after dismissal they were strictly observed. During the period between May and September 2010, these patients underwent their last evaluation, and clinical exams, ECG, TTE, and an ECG-gated-MDCT were performed. At followup TTE results showed an aortic root of 36.7±4 mm and an ascending aorta of 39.6±4.8 mm. ECG- gated CT showed an aortic root of 37.9±5.5 mm and an ascending aorta of 43.1±5.2. The comparison between preoperative and postoperative TTE shows a significant long-term dilatation of the ascending aorta while the aortic root diameter seems to be stable. ECG-gated CT confirms the stability of the aortic root diameter (38.2±5.3 mm versus 37.9±5.5  mm; <0.0001) and the increasing diameter value of the ascending aorta (40.2±3.9 mm versus 43.1±5.2 mm; P=0.0156). Due to the different findings between CT and TTE studies, ECG-gated CT should no longer be considered as a complementary exam in the followup of patients with BAV, but as a fundamental role since it is a real necessity.


2016 ◽  
Vol 20 (2) ◽  
pp. 49
Author(s):  
A. M. Chernyavskiy ◽  
D. S. Khvan ◽  
S. A. Alsov ◽  
D. A. Sirota ◽  
M. M. Lyashenko

<p><strong>Aim:</strong> Emphasis in this study was placed on clinical and functional assessment of a modified "Florida Sleeve" procedure during surgical correction of ascending aorta aneurysms with concomitant aortic insufficiency.<br /><strong>Methods:</strong> 32 patients with an aneurysm of the ascending aorta and aortic insufficiency underwent a modified "Florida Sleeve" procedure. The average follow-up was 17 (0-60) months. The average age of patients was 57±13 (23-73) years 56±13 years.<br /><strong>Results:</strong> The expected 4-year cumulative survival rate was 84.3%. Overall freedom from aortic insufficiency in the late period was 88.9%. Median aortic regurgitation was 1+ (1; 2). Long-term follow-up revealed no valve-associated complications.<br /><strong>Conclusion:</strong> The aortic root reimplantation procedure enables optimal correction of the existing lesions of the aortic root without performing aortic valve replacement and demonstrates stable clinical and functional outcomes in the long-term period.</p><p><strong>Key words:</strong> aortic aneurysm; aortic valve; valve-sparing operations.</p><p><strong>Funding</strong></p><p>The study had no sponsorship.</p><p><strong>Conflict of interest</strong></p><p>The authors declare no conflict of interest.</p>


Sign in / Sign up

Export Citation Format

Share Document