prosthetic valve endocarditis
Recently Published Documents


TOTAL DOCUMENTS

1022
(FIVE YEARS 245)

H-INDEX

55
(FIVE YEARS 5)

Author(s):  
Nguyen Sinh Hien ◽  
Nguyen Huu Phong ◽  
Le Quang Thien

Objective: to evaluate the short-term outcomes of surgical treatment of left-sided infective endocarditis (IE) in Hanoi Heart Hospital. Patients and Methods: A retrospective, cross-sectional and descriptive study on all patients underwent surgery for left-sided IE from 3/2015 to 3/2019 in Hanoi Heart Hospital. Result: 56 patients underwent surgery for left-sided IE in 4 years; the mean age was 45.8 ± 16.0; male-female ratio was 3.3/1. 9 patients (16.1%) had prosthetic valve endocarditis. Preopeative blood cultures were positive in 35.7%, the mainly microorganism was Streptococcus (21.4%). Emergency and urgent surgery was performed in 14.3%; the most frequently postoperative complication was kidney failure, the in-hospital mortality rate was  5.4%. During the average follow-up time of 36.6± 14.2 months, the recurrence rate of IE was 17.8%. Conclusion: surgical treatment of left-sided infective endocarditis is still a great challenge, the early recurrence and motality rate are high.


Medicina ◽  
2021 ◽  
Vol 58 (1) ◽  
pp. 23
Author(s):  
Vedran Carević ◽  
Zorica Mladenović ◽  
Ružica Perković-Avelini ◽  
Tina Bečić ◽  
Mislav Radić ◽  
...  

Despite advances in diagnosis, imaging methods, and medical and surgical interventions, prosthetic valve endocarditis (PVE) remains an extremely serious and potentially fatal complication of heart valve surgery. Characteristic changes of PVE are more difficult to detect by transthoracic echocardiography (TTE) than those involving the native valve. We reviewed advances in transesophageal echocardiography (TEE) in the diagnosis of PVE. Three-dimensional (3D) TEE is becoming an increasingly available imaging method combined with two-dimensional TEE. It contributes to faster and more accurate diagnosis of PVE, assessment of PVE-related complications, monitoring effectiveness of antibiotic treatment, and determining optimal time for surgery, sometimes even before or without previous TTE. In this article, we present advances in the treatment of patients with mitral PVE due to 3D TEE application.


2021 ◽  
Vol 8 ◽  
Author(s):  
Maxwell D. Eder ◽  
Krishna Upadhyaya ◽  
Jakob Park ◽  
Matthew Ringer ◽  
Maricar Malinis ◽  
...  

Infective endocarditis is a common and treatable condition that carries a high mortality rate. Currently the workup of infective endocarditis relies on the integration of clinical, microbiological and echocardiographic data through the use of the modified Duke criteria (MDC). However, in cases of prosthetic valve endocarditis (PVE) echocardiography can be normal or non-diagnostic in a high proportion of cases leading to decreased sensitivity for the MDC. Evolving multimodality imaging techniques including leukocyte scintigraphy (white blood cell imaging), 18F-fluorodeoxyglucose positron emission tomography (FDG-PET), multidetector computed tomographic angiography (MDCTA), and cardiac magnetic resonance imaging (CMRI) may each augment the standard workup of PVE and increase diagnostic accuracy. While further studies are necessary to clarify the ideal role for each of these imaging techniques, nevertheless, these modalities hold promise in determining the diagnosis, prognosis, and care of PVE. We start by presenting a clinical vignette, then evidence supporting various modality strategies, balanced by limitations, and review of formal guidelines, when available. The article ends with the authors' summary of future directions and case conclusion.


2021 ◽  
Vol 8 ◽  
Author(s):  
Jinmiao Chen ◽  
Minzhi Lv ◽  
Yuntao Lu ◽  
Jiahui Fu ◽  
Yingqiang Guo ◽  
...  

Objectives: To evaluate the 2-year clinical safety and hemodynamic outcomes of the Cingular bovine pericardial bioprosthesis.Methods: A prospective, multicenter, single-arm trial was conducted in patients who required aortic or mitral valve replacement. From March 2016 to October 2017, 197 patients were implanted with the Cingular bovine pericardial valve at five sites in China. The clinical outcomes and hemodynamic performance were assessed through a 2-year follow-up. Clinical safety events were reviewed by an independent clinical events committee, and echocardiographic data were assessed by an independent core laboratory.Results: The mean age was 66.9 ± 4.9 years. The 2-year survival rate was 96.4%. A complete 2-year clinical follow-up was achieved in 189 of 190 survivors. No case of structural valve deterioration, major perivalvular leak, prosthetic valve endocarditis, or valve-related reoperation was seen. For the aortic valve, the mean pressure gradient observed was 12.5 ± 4.0 mm Hg, and the effective orifice area (EOA) was 2.0 ± 0.3 cm2. For the smaller size aortic valves, 19 mm and 21 mm, respective mean EOA values of 1.7 ± 0.2 cm2 and 1.8 ± 0.2 cm2 were found. The values for mean pressure gradient and mean EOA for mitral bioprostheses were 4.0 ± 1.4 mm Hg and 2.2 ± 0.3 cm2, respectively. There was no significant change between 1-year and 2-year hemodynamic performance.Conclusions: The Cingular bovine pericardial valve showed favorable clinical safety and hemodynamic outcomes over a 2-year follow-up. Further follow-up is required to validate the long-term durability.


Author(s):  
Ivilin Todorov ◽  
Zdravka P. Todorova ◽  
Dimitar P. Nikolov

Background: Myocardial protection in reoperations in cardiac surgery is extremely difficult in patients with previous coronary surgery and a working LIMA-LAD graft, and it largely determines the outcome of surgery and long-term prognosis. We use a the method of percutaneous angiographic balloon LIMA occlusion and cardioplegic arrest. Aims: The aim of this study was to compare the data of patients with angiographic balloon LIMA-occlusion and those without occlusion in operations related to PVE, and previous coronary surgery with permeable LIMA graft, determining the degree of safety and benefits of method. Study design and Methods: A total of 20 patients undergoing surgery for prosthesis valve endocarditis with patent LIMA-LAD graft were analyzed retrospectively. We divide the patients into 2 groups. Group A patients - with LIMA occlusion and Group B patients - without LIMA occlusion). The pre-, intra- and postoperative results were compared and the degree of safety and benefits of the application of the method were studied. Results: 80% of patients in group A needed only dopamine infusion and 20% needed the addition of a second catecholamine (Adrenaline) at the end of CPB. In group B, the need for double catecholamine maintenance is in 50% of patients. The need for implantation of an intra-aortic balloon pump due to refractory heart failure was registered in 10% of patients in group A and in 20% of patients in group B. It was found that the average duration of mechanical ventilation in group A is 10.5 hours postoperatively, and in group B - 12.5 hours. The mean duration of catecholamine infusion in both groups was 3 days. The average stay in intensive care is shorter for patients in Group A - 2.5 days, and in Group B is 3.5 days. In terms of survival - mortality in the group with LIMA occlusion is 0%, while in the group without LIMA occlusion is 20%. Conclusion: Our reported results from the use of the LIMA balloon occlusion method in patients with prosthetic valve endocarditis who are high-risk and complicated patients and nevertheless the mortality in this group studied by us is 0% and no serious complications of the applied method have been registered. Therefore, we believe that the angiographic balloon LIMA occlusion is a reliable, easily applicable and relatively safe technique that improves the surgical results and prognosis of patients in need of reoperative cardiac surgery.


2021 ◽  
Vol 73 ◽  
pp. S13-S14
Author(s):  
Anupam Dey ◽  
Nilanjan Kar ◽  
Debananda Sahoo ◽  
Sujata Devi

Author(s):  
Manuel Caceres Polo ◽  
Dylan Thibault ◽  
Oliver K. Jawitz ◽  
Brittany A. Zwischenberger ◽  
Sean M. O’Brien ◽  
...  

2021 ◽  
Vol 10 (22) ◽  
pp. 5386
Author(s):  
Rosa Zampino ◽  
Domenico Iossa ◽  
Maria Paola Ursi ◽  
Lorenzo Bertolino ◽  
Arta Karruli ◽  
...  

(1) Background: The aim of this study was to assess the clinical significance and prognostic role of the main hemostasis parameters in infective endocarditis (IE): prothrombin time as international normalized ratio (PT-INR), activated partial thromboplastin time (aPTT), fibrinogen, D-dimers, platelet count, homocysteine. (2) Methods: We studied 337 patients with IE. Clinical, hemato-chemical and echocardiography parameters were analyzed. Coagulation parameters were measured on admission. (3) Results: D-dimers levels (p = 0.012) and a prolonged PT-INR (p = 0.013) were associated with higher in-hospital mortality, while prolonged aPTT (p = 0.021) was associated with increased 1-year mortality. Staphylococcus aureus (S. aureus) infection (p = 0.003), prosthetic valve endocarditis (PVE) (p = 0.001), surgical indication (p = 0.002) and higher D-dimer levels (p = 0.005) were independent predictors of in-hospital mortality. PVE (p = 0.001), a higher Charlson Comorbidity Index (p = 0.049), surgical indication (p = 0.001) and prolonged aPTT (p = 0.012) were independent predictors of 1-year mortality. Higher levels of D-dimers (p < 0.001) and a shorter aPTT (p < 0.001) were associated with embolic complications of IE. S. aureus etiology was bound to higher D-dimers levels (p < 0.001) and a shorter aPTT (p = 0.006). (4) Conclusions: Elevated D-dimers are associated with a higher risk for in-hospital mortality in IE patients. High D-dimers and a short aPTT are associated with a higher risk for embolic events in IE. A longer aPTT is associated with 1-year mortality.


Author(s):  
Christine Johnstad ◽  
Swaroop Bomareddi ◽  
Joshua L. Hermsen ◽  
Jason W. Smith ◽  
Amy G. Fiedler

Sign in / Sign up

Export Citation Format

Share Document