Probabilistic assessment of reactor pressure vessel integrity under pressurised thermal shock

1999 ◽  
Vol 76 (7) ◽  
pp. 445-453 ◽  
Author(s):  
B.K Dutta ◽  
H.S Kushwaha ◽  
V Venkat Raj
1998 ◽  
Vol 75 (15) ◽  
pp. 1055-1064 ◽  
Author(s):  
N.K Mukhopadhyay ◽  
T.V Pavan Kumar ◽  
J Chattopadhyay ◽  
B.K Dutta ◽  
H.S Kushwaha ◽  
...  

Author(s):  
Sam Oliver ◽  
Chris Simpson ◽  
Andrew James ◽  
Christina Reinhard ◽  
David Collins ◽  
...  

Nuclear reactor pressure vessels must be able to withstand thermal shock due to emergency cooling during a loss of coolant accident. Demonstrating structural integrity during thermal shock is difficult due to the complex interaction between thermal stress, residual stress, and stress caused by internal pressure. Finite element and analytic approaches exist to calculate the combined stress, but validation is limited. This study describes an experiment which aims to measure stress in a slice of clad reactor pressure vessel during thermal shock using time-resolved synchrotron X-ray diffraction. A test rig was designed to subject specimens to thermal shock, whilst simultaneously enabling synchrotron X-ray diffraction measurements of strain. The specimens were extracted from a block of SA508 Grade 4N reactor pressure vessel steel clad with Alloy 82 nickel-base alloy. Surface cracks were machined in the cladding. Electric heaters heat the specimens to 350°C and then the surface of the cladding is quenched in a bath of cold water, representing thermal shock. Six specimens were subjected to thermal shock on beamline I12 at Diamond Light Source, the UK’s national synchrotron X-ray facility. Time-resolved strain was measured during thermal shock at a single point close to the crack tip at a sample rate of 30 Hz. Hence, stress intensity factor vs time was calculated assuming K-controlled near-tip stress fields. This work describes the experimental method and presents some key results from a preliminary analysis of the data.


Author(s):  
Vikram Marthandam ◽  
Timothy J. Griesbach ◽  
Jack Spanner

This paper provides a historical perspective of the effects of cladding and the analyses techniques used to evaluate the integrity of an RPV subjected to pressurized thermal shock (PTS) transients. A summary of the specific requirements of the draft revised PTS rule (10 CFR 50.61) and the role of cladding in the evaluation of the RPV integrity under the revised PTS Rule are discussed in detail. The technical basis for the revision of the PTS Rule is based on two main criteria: (1) NDE requirements and (2) Calculation of RTMAX-X and ΔT30. NDE requirements of the Rule include performing volumetric inspections using procedures, equipment and personnel qualified under ASME Section XI, Appendix VIII. The flaw density limits specified in the new Rule are more restrictive than those stipulated by Section XI of the ASME Code. The licensee is required to demonstrate by performing analysis based on the flaw size and density inputs that the through wall cracking frequency does not exceed 1E−6 per reactor year. Based on the understanding of the requirements of the revised PTS Rule, there may be an increase in the effort needed by the utility to meet these requirements. The potential benefits of the Rule for extending vessel life may be very large, but there are also some risks in using the Rule if flaws are detected in or near the cladding. This paper summarizes the potential impacts on operating plants that choose to request relief from existing PTS Rules by implementing the new PTS Rule.


2021 ◽  
Vol 152 ◽  
pp. 107987
Author(s):  
Rakesh Chouhan ◽  
Anuj Kumar Kansal ◽  
Naresh Kumar Maheshwari ◽  
Avaneesh Sharma

Sign in / Sign up

Export Citation Format

Share Document