LEFT HEART CATHETERIZATION DURING HEMODYNAMIC RAMP STUDY PROVIDES A COMPREHENSIVE EVALUATION OF PATIENTS SUPPORTED WITH A LEFT VENTRICULAR ASSIST DEVICE

2018 ◽  
Vol 71 (11) ◽  
pp. A654
Author(s):  
Andrew Rosenbaum ◽  
Sudhir Kushwaha ◽  
John Stulak ◽  
Simon Maltais ◽  
Atta Behfar
Circulation ◽  
2020 ◽  
Vol 142 (Suppl_3) ◽  
Author(s):  
Alexander G Hajduczok ◽  
Katharine Julian ◽  
Carly Maucione ◽  
John P Boehmer

Background: Although hemodynamic-driven Left Ventricular Assist Device (LVAD) speed changes have been shown to improve patient outcomes, there is no standardized algorithm for how to best adjust LVAD speed for optimization of cardiac output (CO) and decompression of left sided filling pressures as measured by pulmonary capillary wedge (PCW). Methods: We performed a retrospective study of LVAD patients at Penn State Hershey Medical Center from 2015 to present, to identify those that ramp studies during right heart catheterizations. 470 patients were identified, of which 60 had ramp studies. Only studies with at least 4 of 5 standard ramp speeds were included. Any study that did not exhibit at least a 20% decrease in PCW, suggesting improper LVAD function or recovered heart function, was also excluded. 32 studies were included in final analysis: 11 HVAD, 12 HMIII, and 9 HMII. CO measured by thermodilution was reported. Standard ramp speeds, in rpm, were as follows: HVAD (2100, 2400, 2700, 3000, 3300), HMIII (4500, 5000, 5500, 6000, 6500), and HMII (8000, 9000, 10,000, 11,000, 12,000). Results: Combined data showed an average CO improvement of 22.3% and average PCW decrease of 89.7%. HMII and HMIII had similar improvements in CO, 44.4% and 43.8%, respectively; much greater than HVAD (17.2%). HMIII had the largest magnitude of decompression 141.5% versus 106.4% for HMII and 56.1% for HVAD. Suction events occurred at an overall rate of 9.4%, and were greatest in HVADs. Conclusion: We report the ramp study hemodynamics for three separate LVADs. Overall, our results suggest the HMIII is most responsive to changes in speed in terms of improvement of CO and decreased PCW. Addition of samples to this analysis may allow for algorithm development to provide clinical guidance regarding LVAD speed settings.


Author(s):  
J P Cassella ◽  
V Salih ◽  
T R Graham

Left ventricular assist systems are being developed for eventual long term or permanent implantation as an alternative to heart transplantation in patients unsuitable for or denied the transplant option. Evaluation of the effects of these devices upon normal physiology is required. A preliminary study was conducted to evaluate the morphology of aortic tissue from calves implanted with a pneumatic Left Ventricular Assist device-LVAD. Two 3 month old heifer calves (calf 1 and calf 2) were electively explanted after 128 days and 47 days respectively. Descending thoracic aortic tissue from both animals was removed immediately post mortem and placed into karnovsky’s fixative. The tissue was subsequently processed for transmission electron microscopy (TEM). Some aortic tissue was fixed in neutral buffered formalin and processed for routine light microscopy.


Sign in / Sign up

Export Citation Format

Share Document