Ultrastructural observations of the aorta of calves implanted with a mechanical left ventricular assist device

Author(s):  
J P Cassella ◽  
V Salih ◽  
T R Graham

Left ventricular assist systems are being developed for eventual long term or permanent implantation as an alternative to heart transplantation in patients unsuitable for or denied the transplant option. Evaluation of the effects of these devices upon normal physiology is required. A preliminary study was conducted to evaluate the morphology of aortic tissue from calves implanted with a pneumatic Left Ventricular Assist device-LVAD. Two 3 month old heifer calves (calf 1 and calf 2) were electively explanted after 128 days and 47 days respectively. Descending thoracic aortic tissue from both animals was removed immediately post mortem and placed into karnovsky’s fixative. The tissue was subsequently processed for transmission electron microscopy (TEM). Some aortic tissue was fixed in neutral buffered formalin and processed for routine light microscopy.

2018 ◽  
Vol 42 (4) ◽  
pp. 201-206 ◽  
Author(s):  
Thomas Schmidt ◽  
Birna Bjarnason-Wehrens ◽  
Stephanie Mommertz ◽  
Sebastian Schulte-Eistrup ◽  
Detlev Willemsen ◽  
...  

Following implantation of a left ventricular assist device, the build-up and long-term maintenance of adequate exercise capacity and functional performance become crucial. The aim of this study was to observe the development of exercise-related values at different times, as well as to detect possible influencing factors. We performed a prospective single-centre study: 10 patients (63 years, 100% male, body mass index = 27.5, 100% HeartWare) underwent the following diagnostic tests during cardiac rehabilitation and during two subsequent ambulatory visits: 6-min walking test, handgrip strength test, cardiopulmonary exercise test and Minnesota Living with Heart Failure questionnaire. Mean follow-up was 482 days after left ventricular assist device implantation. Significant improvements could be observed between the end of cardiac rehabilitation and ambulatory visit 1; 6-min walking distance increased from 367 to 449 m (p < 0.01), peak VO2 from 10.0 to 11.9 mL/kg/min (p < 0.05) and peak load from 62.4 to 83.0 W (p < 0.01). However, there were no further improvements between ambulatory visit 1 and ambulatory visit 2. In the long term, a significant mean weight gain of more than 10 kg could be observed (p < 0.01). A negative linear correlation between weight gain and absolute improvement in peak load (r = −0.77, p < 0.01) and peak VO2 (r = −0.75, p < 0.05) could be demonstrated. In conclusion, exercise-related values following left ventricular assist device implantation initially improve significantly. Later, however, no further improvements can be observed. In the long term, pronounced weight gain is conspicuous, concomitant with a significantly lower increase in exercise values of the patients. In the future, both dietary and structured physical activity follow-up interventions should be integrated in patient routines.


Sign in / Sign up

Export Citation Format

Share Document