Abstract #862881: Expanded Identification of Kinase Fusions Enhances Diagnostic Yield in Thyroid Nodules

2020 ◽  
Vol 26 ◽  
pp. 312
Author(s):  
Richard Kloos
OTO Open ◽  
2020 ◽  
Vol 4 (2) ◽  
pp. 2473974X2092900
Author(s):  
Jagdish K. Dhingra

Objective To study the feasibility, safety, and learning curve of ultrasound-guided fine-needle biopsy (USGFNB) performed by a newly trained otolaryngologist in a community office in a setting. Study Design Collect USGFNB data of all thyroid nodules in a prospective manner. Setting A dedicated ultrasound clinic in a large community-based practice, operated by a single surgeon with the purpose of providing office-based point-of-care diagnostic ultrasonography and USGFNB. Subjects and Methods Data on the first 1000 unselected consecutive thyroid nodules that underwent USGFNB over a 3-year period were analyzed. Chi-square analysis was used to assess the statistical significance of characteristics of diagnostic vs nondiagnostic nodules. A multivariate regression analysis was conducted to determine nodule characteristics predictive of adequate sampling. Diagnostic yield and time efficiency data were plotted over a 3-year period to study the learning curve for the USGFNB procedure performed by an operator with no previous experience. Results A total of 1000 nodules in 734 patients including 142 males and 592 females (age range, 17-87 years) were studied. Of the patients, 188 of 734 had more than 1 nodule biopsied, with a maximum of 4 nodules biopsied in 1 setting. The procedure was successfully completed in all patients, with no major complications. A steep learning curve was observed, and adequate samples were obtained in 91.9% of the patients on the first attempt. The cystic nature of the nodule was the biggest predictor of a nondiagnostic yield. Conclusions Otolaryngologist-performed USGFNB of the thyroid is safe, effective, and desirable.


Thyroid ◽  
2012 ◽  
Vol 22 (6) ◽  
pp. 590-594 ◽  
Author(s):  
Carrie C. Lubitz ◽  
Sushruta S. Nagarkatti ◽  
William C. Faquin ◽  
Anthony E. Samir ◽  
Maria C. Hassan ◽  
...  

2015 ◽  
Vol 173 (5) ◽  
pp. 677-681 ◽  
Author(s):  
Tamira K Klooker ◽  
Anne Huibers ◽  
Klaas in 't Hof ◽  
Els J M Nieveen van Dijkum ◽  
Saffire S Phoa ◽  
...  

BackgroundFine needle aspiration (FNA) cytology is the method of choice to exclude malignancy in thyroid nodules. A major limitation of thyroid FNA is the relatively high rate (13–17%) of non-diagnostic samples. The aim of this study is to determine the diagnostic yield of a screw needle compared to the conventional FNA.MethodsWe retrospectively analysed thyroid nodule cytology of all patients that underwent thyroid nodule fine needle or screw needle aspiration between July 2007 and July 2012 in a single academic medical centre. Cytology results were categorized according to the Bethesda classification system.ResultsIn total, 644 punctures of thyroid nodules from 459 patients were available for analysis. The screw needle was used 531 times, and the conventional fine needle 113 times. The percentage of non-diagnostic cytology was significantly lower in the screw needle samples than in the fine needle samples (3% vs 17%, P<0.001).ConclusionThis study shows a significantly better diagnostic performance of the screw needle compared to the conventional fine needle in cytology of thyroid nodules.


2020 ◽  
Vol 154 (Supplement_1) ◽  
pp. S162-S162
Author(s):  
S Dalal ◽  
D Jhala

Abstract Introduction/Objective Thyroid cancer is one of the most common prevailing conditions. Both genetic and environmental risk factors play a role in causation of thyroid cancers, with agent orange being the most documented risk factor in Veteran patient population. Based on the ultrasonographic appearance, thyroid nodules can be further investigated by minimally invasive fine needle cytology. This can be done by either of two available techniques, Fine needle aspiration with suction (FNA-S) and Fine needle capillary cytology without using suction (FNC), depending upon the preference of practicing endocrinologist. We aim to compare both cytology techniques for comparing the diagnostic yield and rate of atypia of undetermined significance (AUS) or Follicular lesion of undetermined significance (FLUS), requiring repeat FNA in approximately three months. Methods Retrospective study was conducted by searching the cases performed by an endocrinologist at Corporal Michael J Crescenz VA Medical Center between the period of January 1, 2015 and July 2, 2015. 30 nodules from 11 patients were tested by Fine needle capillary cytology technique (FNC). Yield for the diagnosis with rates of atypical (AUS) cytology were compared. On second set of the 29 patients with 38 nodules, both techniques - FNA-S versus FNC were carried out. Adequacy and rate of AUS/FLUS were calculated. Results Out of 30 total nodules performed by fine needle aspiration (FNA-S), all cases yielded diagnostic material. Of them, 14 (46.6%) were diagnosed as AUS and 16 (53.33%) were benign. On the follow-up/re-aspiration by FNC technique, all these 14 nodules were diagnosed benign. On second set of patients on whom both techniques (FNA-S and FNC) were used alternatively, 13 of 38 nodules (34.21%) were diagnosed as AUS/FLUS, 23 (60.52%) were benign/nodular goiter and 2 were non-diagnostic/inadequate (5.2%). Conclusion FNA-S (with suction) yields adequate diagnostic material, however, also has greater number of atypical cytology results requiring repeat patient visit which may increase morbidity with a burden on total health care cost. FNC (without suction) has low rates of AUS/FLUS, is diagnostically superior with excellent smear quality, less blood clots, time savings, and less inconvenience of patients/physician. FNC (without suction) is a modality of choice for an effective screening of thyroid nodules in veterans.


Sign in / Sign up

Export Citation Format

Share Document