focused ultrasound
Recently Published Documents


TOTAL DOCUMENTS

6817
(FIVE YEARS 1700)

H-INDEX

118
(FIVE YEARS 16)

2022 ◽  
Vol 2022 ◽  
pp. 1-13
Author(s):  
Kaixuan Luo ◽  
Yuhong Wang ◽  
Wen-Shiang Chen ◽  
Xiangjun Feng ◽  
Yehui Liao ◽  
...  

Alzheimer’s disease (AD) is the most common type of dementia but lacks effective treatment at present. Gastrodin (GAS) is a phenolic glycoside extracted from the traditional Chinese herb—Gastrodia elata—and has been reported as a potential therapeutic agent for AD. However, its efficiency is reduced for AD patients due to its limited BBB permeability. Studies have demonstrated the feasibility of opening the blood-brain barrier (BBB) via focused ultrasound (FUS) to overcome the obstacles preventing medicines from blood flow into the brain tissue. We explored the therapeutic potential of FUS-mediated BBB opening combined with GAS in an AD-like mouse model induced by unilateral intracerebroventricular (ICV) injection of Aβ1-42. Mice were divided into 5 groups: control, untreated, GAS, FUS and FUS+GAS. Combined treatment (FUS+GAS) rather than single intervention (GAS or FUS) alleviated memory deficit and neuropathology of AD-like mice. The time that mice spent in the novel arm was prolonged in the Y-maze test after 15-day intervention, and the waste-cleaning effect was remarkably increased. Contents of Aβ, tau, and P-tau in the observed (also the targeted) hippocampus were reduced. BDNF, synaptophysin (SYN), and PSD-95 were upregulated in the combined group. Overall, our results demonstrate that FUS-mediated BBB opening combined with GAS injection exerts the potential to alleviate memory deficit and neuropathology in the AD-like experimental mouse model, which may be a novel strategy for AD treatment.


2022 ◽  
Vol 39 (1) ◽  
pp. 173-180
Author(s):  
Julia Simões Corrêa Galendi ◽  
Sin Yuin Yeo ◽  
Dusan Simic ◽  
Holger Grüll ◽  
Stephanie Stock ◽  
...  

Author(s):  
Junsyou Kanashima ◽  
Naohiro Sugita ◽  
Tadahiko Shinshi

The use of ultrasound to destroy microcapsules in microbubble-assisted drug delivery systems (DDS) is of great interest. In the present study, the disruption ratios of capsule clusters were measured by observing and experimentally analyzing microcapsules with polymer shells undergoing disruption by ultrasound. The microcapsules were dispersed in a planar microchamber filled with a gelatin gel and sonicated using 1 MHz focused ultrasound. Different capsule populations were obtained using a filtration technique to modify and control the capsule sizes. The disruption ratio as a function of the concentration of capsules was obtained through image processing of the recorded photomicrographs. We found that the disruption ratio for each population exponentially decreases as the particle number concentration (PNC) increases. The maximum disruption ratio of the diameter-sorted capsules was larger than that of polydispersed capsules. Particularly, for resonant capsule populations, the ratio was more than twice that of polydispersed capsules. Furthermore, the maximum disruption ratio occurred at higher concentrations as the mean particle diameter of the capsule cluster decreased.


2022 ◽  
pp. 175114372110656
Author(s):  
Prashant Parulekar ◽  
James Powys-Lybbe ◽  
Thomas Knight ◽  
Nicholas Smallwood ◽  
Daniel Lasserson ◽  
...  

Background Combined Lung Ultrasound (LUS) and Focused UltraSound for Intensive Care heart (FUSIC Heart - formerly Focused Intensive Care Echocardiography, FICE) can aid diagnosis, risk stratification and management in COVID-19. However, data on its application and results are limited to small studies in varying countries and hospitals. This United Kingdom (UK) national service evaluation study assessed how combined LUS and FUSIC Heart were used in COVID-19 Intensive Care Unit (ICU) patients during the first wave of the pandemic. Method Twelve trusts across the UK registered for this prospective study. LUS and FUSIC Heart data were obtained, using a standardised data set including scoring of abnormalities, between 1st February 2020 to 30th July 2020. The scans were performed by intensivists with FUSIC Lung and Heart competency as a minimum standard. Data was anonymised locally prior to transfer to a central database. Results 372 studies were performed on 265 patients. There was a small but significant relationship between LUS score >8 and 30-day mortality (OR 1.8). Progression of score was associated with an increase in 30-day mortality (OR 1.2). 30-day mortality was increased in patients with right ventricular (RV) dysfunction (49.4% vs 29.2%). Severity of LUS score correlated with RV dysfunction ( p < 0.05). Change in management occurred in 65% of patients following a combined scan. Conclusions In COVID-19 patients, there is an association between lung ultrasound score severity, RV dysfunction and mortality identifiable by combined LUS and FUSIC Heart. The use of 12-point LUS scanning resulted in similar risk score to 6-point imaging in the majority of cases. Our findings suggest that serial combined LUS and FUSIC Heart on COVID-19 ICU patients may aid in clinical decision making and prognostication.


Author(s):  
Kyosuke Shimizu ◽  
Ayumu OSUMI ◽  
Youichi Ito

Abstract A scanning airborne ultrasound source technique was developed to overcome the riskiness of laser ultrasound, which uses an ultrasound source that has a fixed sound wave focusing point and thus requires mechanical motion for sound source scanning. Therefore, the measurement time becomes longer. To solve this problem, we have proposed a method of simultaneously exciting many measurement points in the target using focused ultrasound sources of different frequencies. In this paper, we investigated the visualization of defects in a thin metal plate by the scanning elastic wave source technique using an airborne ultrasound source driven at two frequencies. When the testing was performed using two frequencies, either frequency visualized the defects.


Sign in / Sign up

Export Citation Format

Share Document