Iatrogenic “aortopulmonary window”: percutaneous rescue closure as a bridge to surgical repair

2015 ◽  
Vol 26 (3) ◽  
pp. 609-611 ◽  
Author(s):  
Davide Marini ◽  
Gaetana Ferraro ◽  
Gabriella Agnoletti

AbstractWe present the case of a 15-year-old boy who underwent arterial switch operation due to transposition of the great arteries with severe scoliosis, obstruction of the right coronary ostium, and severe stenosis of the pulmonary trunk. Balloon angioplasty caused a large aortopulmonary shunt provoking myocardial ischaemia and pulmonary hypertension. The traumatic “aortopulmonary window” was percutaneously occluded using an Amplatzer Septal Occluder device as a bridge to surgical repair.

2021 ◽  
Vol 29 ◽  
pp. 1-5
Author(s):  
Marcio Costa ◽  
Edgard Quintella ◽  
Leonardo Hadid ◽  
Verônica Nasr ◽  
Maximiliano Lacoste ◽  
...  

The Gerbode defect is defined as an abnormal communication between the left ventricle and the right atrium, and is etiologically classified as congenital or acquired (iatrogenic or not). The typical treatment consists of surgical repair of the shunt, but transcatheter occlusion of this condition has proven to be a safe and effective therapeutic alternative for such patients, especially for those with prior surgeries. The aim of this study was to report a case of transcatheter closure of an acquired Gerbode defect, using the Amplatzer™ Septal Occluder device, in a 58-year-old patient, with two prior mitral valve replacements, and the consequent post-procedure mechanical hemolysis.


2020 ◽  
pp. 1-2
Author(s):  
Uma Devi Karuru ◽  
Saurabh Kumar Gupta

Abstract It is not uncommon to have prolapse of the atrial septal occluder device despite accurate measurement of atrial septal defect and an appropriately chosen device. This is particularly a problem in cases with large atrial septal defect with absent aortic rim. Various techniques have been described for successful implantation of atrial septal occluder in such a scenario. The essence of all these techniques is to prevent prolapse of the left atrial disc through the defect while the right atrial disc is being deployed. In this brief report, we illustrate the use of cobra head deformity of the device to successfully deploy the device across the atrial septum.


2015 ◽  
Vol 149 (3) ◽  
pp. e38-e39 ◽  
Author(s):  
María-Teresa González-López ◽  
Juan-Miguel Gil-Jaurena ◽  
José-Luis Zunzunegui-Martínez ◽  
Reyes Álvarez-García-Rovés

2021 ◽  
pp. 1-4
Author(s):  
Ikram Massoud ◽  
Atef Yehia

Abstract Pseudoaneurysm of the ascending aorta is rare (1–2%) and a potentially fatal complication following cardiac surgeries. Surgical repair is still the gold standard treatment of ascending aortic pseudoaneurysm. However, endovascular repair methods including stent grafts and Septal Occluder devices have been reported. We report a case of 38-year-old female patient who presented with giant ascending aortic pseudoaneurysm, and aortopulmonary fistula 22 years after modified BlalockTaussig shunt was managed by the transcatheter method. Septal Occluder device 20 mm diameter was delivered to seal the ostium.


2015 ◽  
Vol 10 (S1) ◽  
Author(s):  
María-Teresa González-López ◽  
Juan-Miguel GilJaurena ◽  
José-Luis Zunzunegui-Martínez ◽  
Reyes álvarez-García-Rovés ◽  
Constancio Medrano-López ◽  
...  

Author(s):  
Andrew T. Waberski ◽  
Nina Deutsch

Transposition of the great arteries is a congenital cardiac abnormality that presents in the neonatal period, most commonly as cyanosis. While variations in anatomic features exist, dextro-transposition of the great arteries, the most common form, results in 2 separate circulatory systems in parallel, such that the right ventricle pumps deoxygenated blood to the systemic circulation, and the left ventricle sends oxygenated blood back to the pulmonary circulation. To ensure survival, early diagnosis and intervention to allow for adequate mixing of blood is necessary. The arterial switch operation is the definitive treatment, usually undertaken in the first few days of life. Known complications of surgery include ischemia, bleeding, hemodynamic compromise, and arrhythmias. Anesthetic management must take these factors into account.


2011 ◽  
Vol 21 (4) ◽  
pp. 460-461 ◽  
Author(s):  
Farhad Bakhtiary ◽  
Wilfried Bellinghausen ◽  
Martin Kostelka

AbstractA case of left main coronary artery stenosis is presented in a boy late after an arterial switch operation, with significant ischaemia during exercise with good collateralisation through the right coronary artery. The problem was successfully managed with minimally invasive off-pump coronary artery bypass through median re-sternotomy.


2014 ◽  
Vol 25 (3) ◽  
pp. 594-596 ◽  
Author(s):  
Austine K. Siomos ◽  
Max B. Mitchell ◽  
Brian M. Fonseca

AbstractThe window duct is a rare congenital anomaly that is physiologically similar to an aortopulmonary window but is extrapericardial at the distal pulmonary trunk. The diagnosis is challenging, and surgical management is complex. Our patient is the first and the youngest to be reported with successful closure and diagnosed by magnetic resonance imaging.


Sign in / Sign up

Export Citation Format

Share Document