Hybrid stenting of the arterial duct with carotid cutdown and flip technique: immediate and early results

2021 ◽  
pp. 1-7
Author(s):  
Supratim Sen ◽  
Priya Pradhan ◽  
Sneha Jain ◽  
Dipesh Trivedi ◽  
Pradeep Kaushik

Abstract Stenting of the arterial duct (PDA) has become a standard palliation for ductal-dependent pulmonary circulation. Carotid arterial access provides a direct route for stenting vertical ducts. We evaluated our early results of hybrid ductal stenting via surgical carotid cutdown. Methods and results: In this retrospective single centre cohort study, hybrid PDA stenting was attempted in 11 patients with “flip technique”, between January 2020 and February 2021, and was successful in 10. Median age was 29 days (interquartile range 17.5–87) and mean weight 3.37 ± 1.23 kg. Mean fluoroscopy time was 13.58 ± 5.35 minutes, mean procedure time was 48.50 ± 22.5 minutes, and mean radiation dose was 1719.5 ± 1217.6 mGycm2. Mean time for cutdown was 9.9 ± 2.4 minutes and for haemostasis and suturing was 25.3 ± 11.0 minutes. Median duration of ventilation post-stenting was 26 hours (interquartile range 21–43.75). The median ICU stay post-procedure was 5 days (interquartile range 4–7.25) and mean hospital stay was 12 ± 6.3 days. On early follow-up, carotid patency was confirmed in all patients with colour Doppler, with no intravascular thrombi, narrowing, haematomas, or aneurysms noted. There were no complications secondary to vascular access. There was one early mortality, 27 days post-stenting, which was unrelated to the procedure. Conclusion: This study adds to the limited literature on ductal stenting with carotid access and the flip technique. In our early experience, the hybrid carotid approach is an attractive alternative to percutaneous carotid puncture and has simplified a complex and challenging intervention, with good outcomes.

2016 ◽  
Vol 32 (1) ◽  
pp. 6-12 ◽  
Author(s):  
TY Tang ◽  
JW Kam ◽  
ME Gaunt

Objectives This study assessed the effectiveness and patient experience of the ClariVein® endovenous occlusion catheter for varicose veins from a large single-centre series in the UK. Methods A total of 300 patients (371 legs) underwent ClariVein® treatment for their varicose veins; 184 for great saphenous vein (GSV) incompetence, 62 bilateral GSV, 23 short saphenous vein (SSV), 6 bilateral SSV and 25 combined unilateral great saphenous vein and SSV. Patients were reviewed at an interval of two months post procedure and underwent Duplex ultrasound assessment. Postoperative complications were recorded along with patient satisfaction. Results All 393 procedures were completed successfully under local anaesthetic. Complete occlusion of the treated vein was initially achieved in all the patients, but at eight weeks’ follow-up, there was only partial obliteration in 13/393 (3.3%) veins. These were all successfully treated with ultrasound-guided foam sclerotherapy. Procedures were well tolerated with a mean pain score of 0.8 (0–10). No significant complications were reported. Conclusions ClariVein® can be used to ablate long and short saphenous varicose veins on a walk-in–walk-out basis. Bilateral procedures can be successfully performed, and these are well tolerated as can multiple veins in the same leg. Early results are promising but further evaluation and longer term follow-up are required.


2009 ◽  
Vol 102 (4) ◽  
pp. 269-277 ◽  
Author(s):  
Raymond Roudaut ◽  
Stephane Lafitte ◽  
Marie-Françoise Roudaut ◽  
Patricia Reant ◽  
Xavier Pillois ◽  
...  

2009 ◽  
Vol 20 (1) ◽  
pp. 39-43 ◽  
Author(s):  
Fiona E Willcoxson ◽  
Sangeetha Viswanathan ◽  
John D.R. Thomson ◽  
John L. Gibbs

AbstractObjectiveTo evaluate the safety and efficacy of transcatheter occlusion of the arterial duct without femoral arterial catheterization.BackgroundPatent arterial ducts have been closed percutaneously since the 1960s. It remains standard practice to use arterial access for aortography before, during, and after implantation of the device. Femoral arterial catheterisation has well recognised complications, and should be avoided unless absolutely necessary.MethodsWe reviewed prospectively collected data relating to 389 occlusions of the arterial duct performed consecutively between 1994 and 2004. We inserted Cook detachable coils in 288 instances using the Amplatzer duct occluder in the remaining 101. Information was obtained regarding procedural success, displacement of the device, and re-intervention. We have followed out patients for a median of 1.15 years in those closed with the Amplatzer device, and 1.09 years in those closed with a coil.ResultsIn the patients in whom we used coils, occlusion was possible in 75% using venous access alone. We reintervened in 25 patients, because of embolisation of the device in 6, haemolysis in 5, and residual shunting in 14. On follow-up, complete occlusion had been achieved in 98%. We found trivial stenosis of the left pulmonary artery in 3 patients. When using the Amplatzer device, closure using venous access alone was achieved in 82%, and 2 patients required reintervention because of embolisation of the device. Complete occlusion had been achieved in all patients as judged by follow-up at 1 year, and 2 patients had trivial stenosis of the left pulmonary artery.ConclusionArterial catheterisation is unnecessary in the great majority of patients undergoing occlusion of the arterial duct. Use of venous catheterisation alone is safe, and does not appear to increase the risk of device-related complications.


2020 ◽  
pp. 1-5
Author(s):  
Asim Al Balushi ◽  
Emma Pascall ◽  
Matthew I. Jones ◽  
Shakeel Qureshi ◽  
Gianfranco Butera

Abstract Objectives: We report our experience of using the Bentley BeGraft Aortic stent in patients with severe or near-atretic aortic coarctation and small femoral arterial access. Background: Use of covered stent is recommended in some settings such as aortic coarctation with associated aneurysm, Turner syndrome, and coarctation with aortic atresia. However, currently available covered stents need larger sheaths that may limit their use in children and patients with smaller arterial access. Newer stents may overcome this limitation. Methods: Single-centre retrospective study of patients with severe or near-atretic aortic coarctation and small femoral arterial access. Results: Between July and October, 2019, five patients (median age 15 years) with near-atretic or severe coarctation were treated with a Bentley BeGraft Aortic stent. Long sheaths between 9 and 11 Fr were used to implant stents, which were dilated up to 12–16 mm. None of the patients had residual coarctation (gradient >20 mm of mercury) after stenting. None of the patients developed acute vascular injuries or local access related complications at the end of the procedure or during follow-up (range 6–10 months). Conclusions: Bentley BeGraft aortic stents are important to consider in patients with severe coarctation and provided acute procedural success in patients with small femoral arterial access and widen the applicability in this patient population.


VASA ◽  
2013 ◽  
Vol 42 (4) ◽  
pp. 264-274
Author(s):  
Dagmar Krajíčková ◽  
Antonín Krajina ◽  
Miroslav Lojík ◽  
Martina Mulačová ◽  
Martin Vališ

Background: Intracranial atherosclerotic stenosis is a major cause of stroke and yet there are currently no proven effective treatments for it. The SAMMPRIS trial, comparing aggressive medical management alone with aggressive medical management combined with intracranial angioplasty and stenting, was prematurely halted when an unexpectedly high rate of periprocedural events was found in the endovascular arm. The goal of our study is to report the immediate and long-term outcomes of patients with ≥ 70 % symptomatic intracranial atherosclerotic stenosis treated with balloon angioplasty and stent placement in a single centre. Patients and methods: This is a retrospective review of 37 consecutive patients with 42 procedures of ballon angioplasty and stenting for intracranial atherosclerotic stenosis (≥ 70 % stenosis) treated between 1999 and 2012. Technical success (residual stenosis ≤ 50 %), periprocedural success (no vascular complications within 72 hours), and long-term outcomes are reported. Results: Technical and periprocedural success was achieved in 90.5 % of patients. The within 72 hours periprocedural stroke/death rate was 7.1 % (4.8 % intracranial haemorrhage), and the 30-day stroke/death rate was 9.5 %. Thirty patients (81 %) had clinical follow-up at ≥ 6 months. During follow-up, 5 patients developed 6 ischemic events; 5 of them (17 %) were ipsilateral. The restenosis rate was 27 %, and the retreatment rate was 12 %. Conclusions: Our outcomes of the balloon angioplasty/stent placement for intracranial atherosclerotic stenosis are better than those in the SAMMPRIS study and compare favourably with those in large registries and observational studies.


2014 ◽  
Vol 17 (3) ◽  
pp. 146
Author(s):  
Osman Tansel Darcin ◽  
Mehmet Kalender ◽  
Ayse Gul Kunt ◽  
Okay Guven Karaca ◽  
Ata Niyazi Ecevit ◽  
...  

<p><b>Background:</b> Thoracoabdominal aortic aneurysms (TAAA) present a significant clinical challenge, as they are complex and require invasive surgery. In an attempt to prevent considerably high mortality and morbidity in open repair, hybrid endovascular repair has been developed by many authors. In this study, we evaluated the early-term results obtained from this procedure.</p><p><b>Methods:</b> From November 2010 to February 2013, we performed thoracoabdominal hybrid aortic repair in 18 patients. The mean age was 68 years (12 men, 6 women). All of the patients had significant comorbidities. Follow-up computed tomography (CT) scans were performed at 1 week, 3 months, 6 months, and annually thereafter.</p><p><b>Results:</b> All patients were operated on in a staged procedure and stent graft deployment was achieved. Procedural success was achieved in all cases. All patients were discharged with complete recovery. No endoleaks weres detected in further CT examination.</p><p><b>Conclusion:</b> Our results suggests that hybrid debranching and endovascular repair of extensive thoracoabdominal aneurysms represents a suitable therapeutic option to reduce the morbidity and mortality of TAAA repair, particularly in those typically considered at high risk for standard repair.</p>


Sign in / Sign up

Export Citation Format

Share Document