Flame Photometric Determination of Calcium in Wet-Process Phosphoric Acid

1954 ◽  
Vol 26 (6) ◽  
pp. 1060-1061 ◽  
Author(s):  
J. A. Brabson ◽  
W. D. Wilhide
1954 ◽  
Vol 26 (10) ◽  
pp. 1663-1663 ◽  
Author(s):  
J A. Brabson ◽  
W D. Wilhide

1981 ◽  
Vol 64 (1) ◽  
pp. 25-27 ◽  
Author(s):  
G Bradley Hunter ◽  
Terry C Woodis ◽  
Frank J Johnson

Abstract A method has been developed for the simultaneous determination of Al, Fe, Ca, and Mg in wet-process phosphoric acid by dc argon plasma emission spectrometry. The suppression of Ca and Mg emission by phosphate encountered in flame analyses was nonexistent, and other interferences were minimal. Results obtained by the procedure were compared with those obtained by atomic absorption spectrometry. The paired t-test showed no significant difference between the 2 methods at the 95% confidence level.


1969 ◽  
Vol 52 (3) ◽  
pp. 569-577
Author(s):  
Donald E Jordan ◽  
Jack L Hoyt

Abstract In the described method, water in phosphoric acid is determined by in situ coulometric generation of Karl Fischer reagent with automated end point detection. The variables associated with visual end point detection among different operators are eliminated. Sample size is limited by the generation rate of available coulometers and is 50 mg for samples containing more than 20% water and 100 t o 150 m g for samples containing less than 20% water for a 20 min analysis time . The precision at 99% confidence ranges from 0.43 ± 0.05% for superphosphoric acid to 36.8 ± 0.81% for untreated 10–34–0 base solution; for polished wet process phosphoric acid the precision is 16.49 ± 0.19% compared to 16.70 ± 0.64% by azeotropie distillation. The method is applicable in all systems which do not normally interfere with Karl Fischer reagent; the generating efficiency at the 100% water level is >99%. Coulometer power tube fatigue is the most serious limitation unless a careful check and replacement program is initiated.


1980 ◽  
Vol 63 (2) ◽  
pp. 208-210
Author(s):  
Terry C Woodis ◽  
J R Trimm ◽  
John H Holmes ◽  
Frank J Johnson

Abstract A method for determining uranium, based on extraction with trioctylphosphine oxide and measurement by argon plasma emission spectrometry at 424.17 nm, is described. Results from the argon plasma method compare favorably with results from other methods and are within 1 standard deviation of the composite average of all methods used in an 11-laboratory study.


1962 ◽  
Vol 34 (3) ◽  
pp. 440-441 ◽  
Author(s):  
D. K. Banerjee ◽  
C. C. Budke ◽  
F. D. Miller

Química Nova ◽  
2014 ◽  
Author(s):  
Wenhui Shi ◽  
Lin Yang ◽  
Quanjun Fu ◽  
Zhiye Zhang ◽  
Xinlong Wang

Sign in / Sign up

Export Citation Format

Share Document