scholarly journals Echocardiographic predictors of symptomatic patent ductus arteriosus in extremely-low-birth-weight preterm neonates

2010 ◽  
Vol 30 (8) ◽  
pp. 535-539 ◽  
Author(s):  
F G Ramos ◽  
C R Rosenfeld ◽  
L Roy ◽  
J Koch ◽  
C Ramaciotti
2020 ◽  
Author(s):  
Anchala Bhardwaj ◽  
ARVIND SAILI ◽  
Dinesh Kumar Yadav ◽  
Ajay Kumar

Abstract Background The management of patent ductus arteriosus in preterm neonates continues to be a topic of discussion and controversy. Prolonged ductal patency in preterm neonates has been associated with significant short and long term morbidities and with increased mortality however, policy of routine treatment of all during neonatal period has failed to show significant improvement in long term outcome. Echocardiography has emerged as a promising modality to screen the newborns at risk of adverse effects of ductal shunting. This helps in identifying PDAs that require treatment to ultimately prevent unnecessary therapy or delay of necessary therapy. There are multitude of studies that have evaluated large number of echocardiographic markers for their predictive utility but only few have included all ductal markers together in a single study. The reported sensitivity (26-100%) and specificity (6-100%) of echocardiographic markers vary over a wide range. Thus, this study was planned with an aim to assess the predictive utility of all available ductal markers and their added advantage of having all over few ones in clinically apparent PDA in preterm VLBW newborns.Methods It was an observational prospective study conducted in tertiary care NICU at Lady Hardinge Medical College, Delhi. Fifty preterm very low birth weight (VLBW) newborns underwent four sequential Echo scans within first 72 hrs; first scan within 12 hours then at 24 hrs ,48 hrs and 72 hrs of age and were monitored clinically for the signs of PDA up to two weeks of life or discharge whichever comes later.Results The Ductal diameter, pulsatile ductal flow pattern, Left pulmonary artery (LPA) velocity, Left atrial to aortic width (La/Ao) ratio, Left atrial volume index (LAVI), Left ventricle to aortic width (Lv/Ao) ratio, E/A ratio and Left ventricular output/superior vena caval (LVO/SVC) flow ratio predicted clinically apparent PDA during first 72 hours of life.Conclusion This study provides insights into the predictive utility of other ductal echo markers along with the routinely measured conventional ones during first 72 hours of life in preterm VLBW newborns.


2018 ◽  
Vol 93 (1) ◽  
pp. 89-96 ◽  
Author(s):  
Shyam Sathanandam ◽  
Kaitlin Balduf ◽  
Sandeep Chilakala ◽  
Kristen Washington ◽  
Kimberly Allen ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document