Long-Term Outcome of Mechanical Pulmonary Valve Replacement in 121 Patients with Congenital Heart Disease

2014 ◽  
Vol 63 (05) ◽  
pp. 367-372 ◽  
Author(s):  
Maziar Dehaki ◽  
Alireza Ghavidel ◽  
Gholamreza Omrani ◽  
Hoda Javadikasgari
2021 ◽  
Vol 12 (5) ◽  
pp. 616-627
Author(s):  
Alqasem Fuad H. Al Mosa ◽  
Sreenath Madathil ◽  
Pierre-Luc Bernier ◽  
Christo Tchervenkov

Background: Late pulmonary valve replacement following repair of tetralogy of Fallot may become necessary in patients with chronic pulmonary insufficiency. There is limited information on the long-term outcome of these prostheses, which is the focus of this study. Methods: We conducted a retrospective study of patients with repaired tetralogy of Fallot who underwent pulmonary valve replacement from 1990 to 2015 in our institution. We investigated imaging and clinical parameters including mortality and late adverse events (reintervention [surgical or transcatheter]), infective endocarditis, or arrhythmias requiring device implantation or ablation. Results: There were 69 patients divided into 3 groups: Carpentier-Edwards (n = 14), Contegra (n = 40), and pulmonary homograft (n = 15). The mean age at the time of pulmonary valve replacement was 21 ± 12 years. The mean follow-up was 8.5 ± 4.7 years. The mean preoperative and postoperative right ventricular end-diastolic volume index was 210 ± 42 and 120 ± 24 mL/m2, respectively. There were no mortalities. Late adverse events were observed in 23 (33%) patients: 15 (22%) reintervention (surgical or transcatheter), 11 (16%) endocarditis, and 11 (16%) arrhythmias. Overall, 1-, 5-, and 10-year freedom from surgical reintervention was 98.5%, 93.6%, and 79.3%, respectively. The Contegra group had significantly higher pulmonary valve gradients, a higher risk of developing late adverse events compared to Carpentier-Edwards ( P = .046) and pulmonary homograft ( P = .055) in multivariate analysis and increased risk for reintervention in the univariate analysis (hazard ratio: 3.4; 95% CI: 0.92-13; P value.066). Conclusion: Pulmonary valve replacement in patients with repaired tetralogy of Fallot has acceptable short- and intermediate-term outcomes. Contegra prosthesis had a higher risk of late adverse events with higher pulmonary valve gradients.


2016 ◽  
Vol 152 (5) ◽  
pp. 1333-1342.e3 ◽  
Author(s):  
Rio Nomoto ◽  
Lynn A. Sleeper ◽  
Michele J. Borisuk ◽  
Lisa Bergerson ◽  
Frank A. Pigula ◽  
...  

Author(s):  
Charlotte Brouwer ◽  
Joachim Hebe ◽  
Peter Lukac ◽  
Jan-Hendrik Nürnberg ◽  
Jens Cosedis Nielsen ◽  
...  

Background: Poor outcome after atrial tachycardia (AT) radiofrequency catheter ablation (RFCA) in repaired congenital heart disease (CHD) has been attributed to CHD complexity. This may not apply to contemporary patients. The objective of our study was to assess outcome after RFCA for AT in contemporary patients with CHD according to prior atrial surgery and predefined procedural end points. Methods: Patients with CHD referred for AT RFCA to 3 European centers were classified as no atrial surgery/cannulation only, limited or extensive prior atrial surgery. Procedural success was predefined as termination and nonreinducibility for focal AT and bidirectional block across ablation lines for intra-atrial reentrant tachycardia and after empirical substrate ablation for noninducible patients. Patients were followed for AT recurrence and mortality. Results: Ablation was performed in 290 patients (41±17 years, 59% male; 3-dimensional mapping 89%, irrigated tip catheters 90%, transbaffle access 15%). In 197, 233 AT were targeted (196 intra-atrial reentrant tachycardia [64% cavotricuspid (mitral) isthmus–dependent, 33% systemic-venous incision–dependent] and 37 focal AT). In 93 noninducible patients, empirical substrate ablation was performed. Procedural success was achieved in 209 (84%) patients. AT recurred in 148 (54%) 10 (interquartile range, 0–25) months after RFCA. AT-free survival was significantly better in patients with no atrial repair/cannulation only and in patients with complete procedural success independently of CHD complexity. From 94 patients undergoing reablation, the initially targeted substrate had recovered in 64%. Conclusions: In contemporary patients with CHD, outcome after AT ablation is associated with presence of prior atrial surgery and achievement of predefined procedural end points rather than CHD complexity. Techniques to improve lesion durability are likely to further improve long-term outcome.


2021 ◽  
pp. 1-4
Author(s):  
Jose M. Arribas-Leal ◽  
Maria Garcia-Vieites ◽  
Antonio Jimenez-Aceituna ◽  
Sergio Canovas-Lopez ◽  
Francisco Gutierrez ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document