scholarly journals VARIOUS ANOMALIES OF THE THORAX

2014 ◽  
Vol 04 (01) ◽  
pp. 138-140
Author(s):  
Vrinda Hari Ankolekar ◽  
Antony Sylvan D'Souza ◽  
Lydia S. Quadros ◽  
Mamatha H. ◽  
Suhani S. ◽  
...  

Abstract:During routine dissection of the thoracic region of a 55-year old male cadaver, in the department of Anatomy, Kasturba Medical College, Manipal, various anomalies were noticed in the thoracic region.a) The arch of aorta gave rise to four branches, the right common carotid artery, left common carotid artery, left subclavian artery and a right subclavian artery. The origin of the right subclavian artery was to the left of the midline and in order to reach the right arm, the artery coursed behind both the trachea and oesophagus.b) Cervical rib was present on both the sides.c) Thoracic duct coursed on the same side without crossing to the left at the T5 vertebral level.d)Hemiazygos vein was underdeveloped.

2013 ◽  
Vol 19 (3) ◽  
pp. 154-159 ◽  
Author(s):  
A.M. Manole ◽  
D.M. Iliescu ◽  
A. Rusali ◽  
P. Bordei

Abstract Our study was conducted by the evaluation of angioCT’s performed on a GE LightSpeed VCT64 Slice CT Scanner. The measurements were performed on the aortic arch at the following levels: at the origin of the aorta, the middle part of the ascending aorta, prior to the origin of the brachiocephalic arterial trunk and after the origin of the left subclavian artery. We measured the caliber of the aortic arch arteries and the data are correlated and reported by gender. The diameter of the ascending aorta was between 27 to 28.9 mm in females and in males from 25.8 to 37.6 mm. The diameter of the aorta within the middle segment of the ascending part was between 28-30.2 mm in females and in males from 26.1 to 34.6. The diameter of the aortic arch prior to the origin of the brachiocephalic arterial trunk was between 26.4 to 29.4 mm in females and in males from 25.8 to 37.5 mm. The diameter of the aortic arch after the origin of the left subclavian artery was in a range of 20.4 to 28.4 mm, which corresponds to the limits found in males while in females the aortic diameter was between 21.3 to 24.1 mm. The brachiocephalic trunk diameters were 8.3 to 15.5 mm in females and in males was 9.1 to 14.5 mm. The right common carotid artery had a diameter of 4-8 mm diameter in males and in females ranged from 4.7 to 5.5 mm. The right subclavian artery showed a caliber of 5.7 to 7.5 mm in females and in males from 5.9 to 10.1. The left common carotid artery diameter was 4.6 to 5.7 mm in females and males the diameter was between 5.2 to 7.4 mm. The left subclavian artery had a diameter of 6-10 mm in females and in males ranged from 7.7 to 12.8 mm. We found that the distance between the ascending part of the aorta and the descending segment ranged from 33.3 to 38.5 mm in females and in males from 40 to 68.6 mm. We measured the distance that exists at the crossing of the aortic arch with the left branch of the pulmonary trunk, finding that in females this distance is 3 to 10.3 mm and in males from 3 to 12.5 mm.


2011 ◽  
Vol 56 (No. 3) ◽  
pp. 131-134 ◽  
Author(s):  
A. Aydin

This study had the aim of investigating the anatomy of the aortic arch in squirrels (Sciurus vulgaris). Ten squirrels were studied. The materials were carefully dissected and the arterial patterns of arteries originating from the aortic arch were examined. The brachiocephalic trunk and the left subclavian artery were detached from the aortic arch. The brachiocephalic trunk first gave the left common carotid artery, and then detached to the right subclavian and common carotid artery. In all the examined materials, the left and right subclavian arteries gave branches that were similar after leaving the thoracic cavity from the cranial thoracic entrance. But while the whole branches of the the right subclavian artery were arising from almost the same point the left subclavian artery gave these branches in a definite order, and the branches that separated were the following: the internal thoracic artery, the intercostal suprema artery, the ramus spinalis, the vertebral artery and the descending scapular artery. It also gave the common branch formed by the junction of three of the cervical superficial, the cevical profund and the suprascapular arteries. After the separation of these branches, continuation of the artery gave the external thoracic artery on the external face of the thoracic cavity and then formed the axillar artery. The axillary artery separated into the subscapular and the brachial arteries. Thus, the arteries originating from the aortic arch and the branches of these arteries are different from other rodents and from domestic mammals.


2014 ◽  
Vol 2014 ◽  
pp. 1-3
Author(s):  
Neelesh Kanaskar ◽  
P. Vatsalaswamy ◽  
Preeti Sonje ◽  
Vaishali Paranjape

During routine dissection of head and neck region in a 65-year-old female cadaver variation in the origin of right subclavian artery was found. The right subclavian artery originated as a direct branch of arch of aorta distal to the origin of left subclavian artery and it was found passing behind esophagus (retroesophageal) and ascending upwards to the right side while the left subclavian artery originated normally from arch of aorta distal to the origin of left common carotid artery. Anomalous variations in the origin and course of arteries have serious implications in angiographic and surgical procedures; hence it is of great importance to be aware of such possibilities of variations.


ISRN Anatomy ◽  
2013 ◽  
Vol 2013 ◽  
pp. 1-5 ◽  
Author(s):  
Virendra Budhiraja ◽  
Rakhi Rastogi ◽  
Vaishali Jain ◽  
Vishal Bankwar ◽  
Shiv Raghuwanshi

Variations of the branches of aortic arch are due to alteration in the development of certain branchial arch arteries during embryonic period. Knowledge of these variations is important during aortic instrumentation, thoracic, and neck surgeries. In the present study we observed these variations in fifty-two cadavers from Indian populations. In thirty-three (63.5%) cadavers, the aortic arch showed classical branching pattern which includes brachiocephalic trunk, left common carotid artery, and left subclavian artery. In nineteen (36.5%) cadavers it showed variations in the branching pattern, which include the two branches, namely, left subclavian artery and a common trunk in 19.2% cases, four branches, namely, brachiocephalic trunk, left common carotid artery, left vertebral artery, and left subclavian artery in 15.3% cases, and the three branches, namely, common trunk, left vertebral artery, and left subclavian artery in 1.9% cases.


2021 ◽  
Vol 25 (3) ◽  
pp. 83
Author(s):  
V. A. Mironenko ◽  
V. S. Rasumovsky ◽  
A. A. Svobodov ◽  
S. V. Rychin

<p>We herein report the first clinical case of prosthetic replacement of the ascending aorta and aortic arch to repair a giant aneurysm in a 7-month-old child. The ascending aorta and arch replacement to the level of left subclavian artery was performed using a no. 16 Polymaille prosthesis, the brachiocephalic trunk was reimplanted into the vascular prosthesis and the kinked section of the left common carotid artery was removed, followed by reimplanting the left common carotid artery into the left subclavian artery. First, proximal anastomosis with the vascular prosthesis was created using a no. 16 Polymaille prosthesis and the vascular suture was strengthened with a Teflon strip. During circulatory arrest, the aortic arch was crossed between the orifice of the left common carotid artery and left subclavian artery, with the cut extended to the isthmus region along the small curvature of the arch. The brachiocephalic trunk was aligned and brought down, with subsequent implantation into the ascending aorta prosthesis 2 cm below the initial fixation point. In the final stage, the kinked section of the left common carotid artery was resected and the aligned left carotid artery was directly reimplanted into the left subclavian artery using end-to-side anastomosis. The patient developed tracheobronchitis and moderate heart failure during the postoperative period. The duration of mechanical ventilation was 16 hours. Infusion and antibacterial therapy were discontinued on postoperative day 8. On postoperative day 13, the patient was discharged and referred to the outpatient centre for further treatment and rehabilitation. A sufficiently large-sized prosthesis allows for further development in paediatric patients. This is facilitated by the preservation of the native aortic root with restored valve function and the formation of a bevelled distal anastomosis with a small unchanged aortic section in the isthmus region, which maintains growth potential. This first reported case of an infant demonstrates the possibility of combination interventions on the aortic arch and brachiocephalic artery during the first year of life.</p><p>Received 30 January 2021. Revised 24 March 2021. Accepted 29 March 2021.</p><p><strong>Funding:</strong> The study did not have sponsorship.</p><p><strong>Conflict of interest:</strong> The authors declare no conflicts of interests.</p><p><strong>Contribution of the authors: </strong>The authors contributed equally to this article.</p>


2014 ◽  
Vol 27 (4) ◽  
pp. 234-236
Author(s):  
Agnieszka Mocarska ◽  
Miroslaw Szylejko ◽  
Elzbieta Staroslawska ◽  
Franciszek Burdan

Abstract The aortic arch usually gives off three major arterial branches: the brachiocephalic trunk, the left common carotid artery and the left subclavian artery. The most frequently occurring developmental variations of arterial trunks origins are a joined brachiocephalic and left common carotid artery origin, the left vertebral artery branching from the aortic arch, a double aortic arch, and a change of sequence of branching arteries. The current report presents the rare asymptomatic situation of the right subclavian artery originating as the last individual branching from the aortic arch. This abnormality was accidentally discovered in a computed tomography examination of a 69-year old male patient. The examination showed that the artery went towards the neck posteriorly from the trachea. The anatomical anomaly was interpreted as being an arteria lusoria.


2021 ◽  

To create an optimal landing zone (zone 2) in the aortic arch for concomitant or subsequent thoracic endovascular aortic repair of aortic diseases (aneurysm, dissection), surgeons frequently need to debranch the supra-aortic vessels. We present a surgical debranching of the left subclavian artery by performing a centrally located bypass from the left common carotid artery to the left subclavian artery.


2019 ◽  
Vol 56 (3) ◽  
pp. 587-594 ◽  
Author(s):  
Huey-Shiuan Kuo ◽  
Jih-Hsin Huang ◽  
Jer-Shen Chen

Abstract OBJECTIVES This study aimed to evaluate the efficacy and safety of a handmade fenestrated stent graft over an aortic stent graft for preserving the left subclavian artery (LSA) in thoracic endovascular aortic repair (TEVAR). METHODS From July 2015 to October 2018, a total of 32 consecutive patients with various thoracic aortic pathologies who underwent TEVAR in which handmade fenestration over a thoracic aortic stent graft was used for LSA were included. Outcomes including technical success, procedure-related complications, perioperative mortality and morbidity and graft patency were analysed. RESULTS Twenty-four patients (75.00%) presented with aortic dissection, 5 patients (15.63%) with thoracic aortic aneurysm and 2 patients (6.25%) with penetrating aortic ulcer; 1 patient (3.13%) required re-TEVAR due to endoleak and sac expansion from previous TEVAR for thoraco-abdominal aneurysm. TEVAR was performed in a zone 2 landing with single fenestration for LSA (26 patients, 81.25%), zone 1 landing with double fenestration for both LSA and left common carotid artery (5 patients, 15.63%) or zone 1 landing with single fenestration for LSA and a chimney graft for left common carotid artery (1 patient, 3.13%). The technical success rate, defined as the successful alignment of fenestration to LSA, was 93.75%. At a mean follow-up of 17.3 months, 4 cases of endoleak and 2 cases of stent graft-induced new entry were noted, 3 of which were treated endovascularly. CONCLUSIONS Our preliminary results demonstrate the viability of preserving LSA blood flow in TEVAR using a handmade stent graft fenestration to treat various aortic pathologies in various clinical situations and the technical feasibility and short-term results that may justify the use of this method in emergency cases.


2015 ◽  
Vol 04 (02) ◽  
pp. 102-104
Author(s):  
Sudipa Biswas ◽  
Suranjali Sharma ◽  
Sanjib Kumar Ghosh ◽  
Soumya Chakraborty

AbstractIn this rare case, found during routine dissection of head and neck in North Bengal Medical College on the right side of the neck, common carotid artery bifurcated at a higher level than usual and 1.25 cm below the bifurcation, gave a common origin of lingual and superior thyroid artery from its medial side (thyorolingual trunk). No such anomaly was noted on the left side. This type of combination of variations has important clinical implications.


Sign in / Sign up

Export Citation Format

Share Document