Treatment Outcomes for Periprosthetic Femoral Fractures in Cementless Press-Fit Total Hip Replacement

2020 ◽  
Vol 33 (05) ◽  
pp. 370-376
Author(s):  
Isobel C. Monotti ◽  
Christopher A. Preston ◽  
Scott W. Kidd

Abstract Objective The aim of this study was to report outcomes in dogs with periprosthetic femoral fractures associated with a press-fit cementless femoral total hip replacement implant. Materials and Methods Electronic medical records and digital radiographs were used to identify dogs with periprosthetic femoral fractures associated with press-fit cementless total hip replacement. Data collected included signalment, weight, time of fracture, cause of fracture, presence of intra-operative fissure, fracture type, repair technique, and clinical and radiographic outcomes. Long-term patient outcome was assessed by communication with owners or referring veterinarians. Results Twenty-eight dogs with femoral fracture repair associated with cementless press-fit total hip replacement were identified. Eight of the fractures occurred intraoperatively and 20 occurred at a median of 2 days postoperatively. An oblique or spiral configuration was noted in 19 cases and 15 occurred at the distal end of the femoral stem (type B), with thirteen type B1, one type B2 and one type B3 fractures. Fractures were repaired with non-locking (18/28) or locking-plate fixation (10/28). Cerclage wire was applied around the plate and proximal bone segment in 17/28 dogs. Major complications occurred in 7/28 cases (five deep infection, two mechanical failures). Bone healing was noted in 21/23 cases, for which follow-up radiographic interpretation was available. Return to function was complete in 17 cases, acceptable in 8 cases and unacceptable in 3 cases. Conclusions While cementless total hip replacement periprosthetic femoral fractures can be successfully repaired with lateral plate fixation, the risk of infection appears to be high.

2016 ◽  
Vol 29 (05) ◽  
pp. 402-408 ◽  
Author(s):  
Christopher Preston ◽  
George Moore ◽  
Scott Kidd

SummaryObjective: To report postoperative complications using a commercially available porous-coated press-fit cementless total hip replacement (THR) system in dogs.Methods: Medical records were reviewed for client-owned dogs with hip pathologies requiring THR. A minimum of six-week postoperative orthopaedic examination and orthogonal pelvic radiographs were used to assess outcome and complications in the perioperative period. Referring veterinarian medical records, phone interviews with clients, or both were used to assess long-term functional outcome and complications.Results: Bilateral THR was performed in 36 dogs, and unilateral in 147 dogs, making a total of 219 THR procedures in 183 dogs. A total complication rate of 31.1% (68/219) was observed. A catastrophic complication was observed in 8.2% (n = 18), a major complication in 9.6% (n = 21), and a minor complication in 13.2% (n = 29) of procedures. The most common complications were intra-operative femoral fissure (n = 46), diaphyseal femoral fracture (n = 15), and coxofemoral luxation (n = 9). Full return to function was achieved in 88.1% of procedures with a median follow-up period of 42 months.Clinical significance: Porous-coated press-fit cementless collarless total hip replacements have a high complication rate. The majority of complications occur intra-operatively or perioperatively, with few complications occurring beyond 12 weeks postoperatively. Both fissure fractures and diaphyseal femoral fractures carry a favourable prognosis with immediate cerclage wiring and plate fixation, respectively.


2016 ◽  
Vol 29 (06) ◽  
pp. 541-546 ◽  
Author(s):  
Michael Ficklin ◽  
Michael Kowaleski ◽  
Kevin Kunkel ◽  
Jonathan Suber

SummaryA two-year-old, 44 kg dog with a right Helica cementless total hip replacement (THR) was radiographically diagnosed with implant loosening eight months after the index total hip replacement procedure. Subsequent synoviocentesis and synovial fluid culture revealed a methicillin-resistant coagulase-negative Staphylococcus spp infection of the right THR. A one-stage revision using a hybrid BFX cementless acetabular cup and CFX cemented femoral stem was performed. Vancomycin and micro-silver antimicrobial powder impregnated cement were used in the revision. At re-evaluation 27 months following the revision procedure, the patient did not exhibit any signs of lameness. Radiographic images confirmed stable implants, with bone ingrowth into the cup and no signs of implant loosening. Our report demonstrates the success of a one-stage THR revision when faced with a multi-drug resistant periprosthetic infection, when combined with the use of micro-silver antimicrobial powder and culture-based antibiotic impregnated cement therapy.


2012 ◽  
Vol 11 (1) ◽  
pp. 26-34
Author(s):  
Sophia N. Sangiorgio ◽  
Edward Ebramzadeh ◽  
Sean L. Borkowski ◽  
Daniel A. Oakes ◽  
Jeremy J. Reid ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document